User manual HONEYWELL MP953B

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL MP953B. We hope that this HONEYWELL MP953B user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL MP953B.


Mode d'emploi HONEYWELL MP953B
Download
Manual abstract: user guide HONEYWELL MP953B

Detailed instructions for use are in the User's Guide.

[. . . ] V5049A V5050A V5025A 43161276-001 V5016A V5328A V5329A V5329C V5011R, S V5013R, E 43297431-001 V5328A V5329A V5329C DN 15. . . 32 PN 6 DN 15. . . 32 PN 16 applied to valves DN 15. . . 65 DN 15. . . 80 DN 15. . . 80 DN 15. . . 80 DN 40. . . 80 DN 40. . . 80 PN 16 PN 6 PN 25/40 PN 25 flow Fig. Typical operation INSTALLATION General Ensure that the actuator has the correct size and travel to match the valve body. Refer to the corresponding valve product literature. Mounting the MP953A, C (Size 5") 1. Position the stem-locking slide so that the large hole is in view (see also Fig. [. . . ] Turn the stem connector screw by its screw-slot counterclockwise to back out the stem button until the actuator is in contact with the shoulder of the stem button. Push the actuator onto the valve bonnet and hold it firmly in place; tighten the two set screws 6. Load the stem by turning the stem connector screw clockwise by its screw slot. a) On a straight-through valve (position 1), turn the stem connector screw until a clearance A of approx. 3 mm (1/8") exists between the spring and the actuator spider. b) On a three-way valve, a clearance A and B of approx. 1. 5 mm each is required at both ends of the stroke to permit proper close-off. If there is no air on the actuator, adjust the A clearance approx. 1. 5 mm and recheck the B clearance when air is available. If clearances A and B cannot be adjusted following the procedure outlined above, check the stem height "y" and adjust, if necessary. Y1 without stem extension for MP953A, C 5" MP953B, D7" Y2 with stem extension for MP953A, C 8" Fig. Stem extensions Mounting the MP953B, D 1. Attach the stem connector screw to stem button (Fig. Place the actuator on the valve without pushing the stem down. ADJUSTMENTS NOTE: Adjustments are necessary only for the GRADUTROL-Relay used with the MP953A, B. The range is adjusted using six adjustment screws (see also Fig. All devices are factory-set for 35 kPa range. This point is adjusted by turning the adjustment knob. The graduations of the external calibration scale on the knob present various values within the different ranges. All devices are factory-set for 35 kPa start point. After completing the adjustment procedure, do not change the position of GRADUTROL-Relay (with respect to the actuator). stem button connector clearance "B" (measured when spring is compressed) clearance "A" set screw Fig. Attaching the stem connector screw 3 EN0B-0552GE51 R1009 Y3 with stem extension for MP953A, C 13" MP953A, B, C, D PNEUMATIC ACTUATORS set screw operating range 70 kPa (10 psi) range adjustment ALL screws "1" and "2" tightened. [. . . ] EXAMPLE: Range setting 35 kPa start point setting 21 kPa. The gauge should then read 56±5 kPa after the travel is completed. If the measured pressure should not be within the permissible variation, fine adjustments must be done (if necessary) using the start point adjustment knob. MP953A + C5'' MP953B + D MP953A + C8'' V5011A V5049A V5328A V5013A V5049B V5050A V5329A, C travel travel y y MOUNTING WITH EXTENSION YOKE For working temperatures of 150 to 220 °C (300 to 425 °F), use of an extension yoke is mandatory for the MP953A, C (5" and 8") and the MP953B, D actuators to protect the diaphragm against excessive heat. Screw the stem extension (for the 5" size) onto the stem, with the stem either pulled out or pushed in (see Fig. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL MP953B

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL MP953B will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag