User manual HONEYWELL MT010-3M

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL MT010-3M. We hope that this HONEYWELL MT010-3M user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL MT010-3M.


Mode d'emploi HONEYWELL MT010-3M
Download
Manual abstract: user guide HONEYWELL MT010-3M

Detailed instructions for use are in the User's Guide.

[. . . ] The actuators are designed for applications where space is limited. Suitable valves include: the 2-way and 3-way V58xxA/C series of small linear valves with 2. 5-mm stroke; TRV's V300 and V2000; Therafix TRV V2464 and V2474 series with 2. 5-3-mm stroke Thermostatic radiator V90 valves with connection size M30x1. 5. [. . . ] stroke Stem force Ambient temperature Power supply Control signal Input resistance Initial current Permanent current Power consumption Protection standard Cable length Cable wires Suitable valves 30 s/mm 3. 5 mm 100 N ±5% max. 60 °C 24 Vac, -20%/+40%, 50. . . 60 Hz modulating 0. . . 10 Vdc 100 k 250 mA 83 mA 2W IP54 1m 3 x 0. 22 mm2 PVC See section "Application" NOTE: Opening and closing times depend upon ambient temperature. ® E. C. Registered Trademark Copyright © 2007 Honeywell Inc. · All Rights Reserved EN0B-0622GE51 R1007 MT010-3M, MT010-3MN SMALL LINEAR THERMOELECTRIC ACTUATORS ­ PRODUCT DATA Dimensions Characteristic Fig. voltage) Ordering Information order number MT010-3M MT010-3MN power supply 24 V control signal 0. . . 10 Vdc actuator action At 0 V and power loss, actuator extends (2-way valve closes and 3-way valve opens) cable length 1m 3m Installation Positions Assembly Fig. Wiring diagram "First Open" Function Auto-Calibration The closing point (drive is closed) is checked twice daily in the active status (UST > 0. 5 V). If there is a deviation, then the calibration process is repeated. Hash (Disturbing Signals) Fig. "First open" function A calibration process is carried out in order to optimally adjust the actuator to the existing valve each time the operating voltage is applied. During this process, the actuator completely opens and closes the valve, while prominent points are simultaneously stored. The control signal is ignored during this process. [. . . ] The control signal is ignored during this process. After the calibration process, the actuator is ready for use and converts the applied control signal into a proportional stroke. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL MT010-3M

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL MT010-3M will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag