[. . . ] SMALL LINEAR THERMOELECTRIC ACTUATORS
Smart-T
PRODUCT DATA
MT4-024/MT4-230 MT8-024/MT8-230
FEATURES
· No mounting tools required (easily mounted using valve adapter) · Water-protected housing design in all mounting positions · Pluggable cable for easy installation and servicing · Auxiliary switch models for driving pumps or fans · Low power consumption models · Normally-open and normally-closed models · Compact design allows installation in limited space · Visual indicator showing valve position and type of action (NO or NC) · Noiseless operation · Reliable long-term operation · Overload protection (4 kV) for 230 V models
SPECIFICATIONS
Max. stroke MT4: 4 mm MT8: 8 mm MTx-024: 24 Vac/dc ± 20% MTx-230: 230 Vac +10% . . . [. . . ] Registered Trademark Copyright © 2009 Honeywell Inc. · All rights reserved
EN0B-0490GE51 R0709
MT SMALL LINEAR THERMOELECTRIC ACTUATORS
ORDERING INFORMATION
Table 1. Actuators order number action* additional features voltage stroke MT4-024-NC normally closed MT4-024-NO normally open MT4-024-NC-2. 5M normally closed 2. 5 m cable length MT4-024-NO-2. 5M normally open 24 Vac/dc MT4-024LC-NC normally closed with low power consumption MT4-024LC-NO normally open MT4-024S-NC normally closed with auxiliary switch MT4-024S-NO normally open 4 mm MT4-230-NC normally closed MT4-230-NO normally open MT4-230-NC-2. 5M normally closed 2. 5 m cable length MT4-230-NO-2. 5M normally open 230 Vac/dc MT4-230LC-NC normally closed with low power consumption MT4-230LC-NO normally open MT4-230S-NC normally closed with auxiliary switch MT4-230S-NO normally open MT8-024-NC normally closed MT8-024-NO normally open MT8-024-NC-2. 5M normally closed 2. 5 m cable length MT8-024-NO-2. 5M normally open 24 Vac/dc MT8-024LC-NC normally closed with low power consumption MT8-024LC-NO normally open MT8-024S-NC normally closed with auxiliary switch MT8-024S-NO normally open 8 mm MT8-230-NC normally closed MT8-230-NO normally open MT8-230-NC-2. 5M normally closed 2. 5 m cable length MT8-230-NO-2. 5M normally open 230 Vac/dc MT8-230LC-NC normally closed with low power consumption MT8-230LC-NO normally open MT8-230S-NC normally closed with auxiliary switch MT8-230S-NO normally open *Without power, in combination with standard 2-way valve; "normally closed" = stem extends, "normally open" = stem retracts Table 2. Accessories order number MT-CLIP MT-ADAPT-HW MT-ADAPT-HP MT-CABLE-1. 5M MT-CABLE-2. 5M MT-CABLE-5M MT-CABLE-10M EVA10RA HCA1VEL description mounting clip, 10 units mounting adapter M30 x 1. 5, 10 units mounting adapter for Herz/Polytherm valves, 10 units cable suitable for MT4-024/-230/-024LC/-0230LC and MT8-024/-230/024LC/-0230LC, 10 units Danfoss-RA adapters, 10 units Mounting adapter for Velta compact manifold
EN0B-0490GE51 R0709
2
MT SMALL LINEAR THERMOELECTRIC ACTUATORS
ELECTRICAL SPECIFICATIONS
Table 3. Electrical specifications order number initial current* permanent current* power consumption* <3W <2W 3W 2W min. runtime for full nominal valve stroke 4 mm models 8 mm models 4. 0 min 6. 0 min 6. 0 min 7. 5 min 2. 5 min 3. 5 min 3. 5 min 5. 5 min
MTx-024-xx, MTx-024S-xx ~0. 7 A < 0. 1 A MTx-024LC-xx ~0. 2 A < 0. 05 A MTx-230-xx, MTx-230S-xx ~0. 6 A** 0. 014 A MTx-230LC-xx ~0. 4 A** 0. 010 A *All values at nominal voltage. **Average during first 500 msec.
MOUNTING
NOTE: Connection leads must not touch piping (heat transfer).
Fig. Mounting / installation positions When the operating current is applied, a PTC resistor heats up a wax element. After a delay, this wax element expands, causing stroke movement.
3
EN0B-0490GE51 R0709
MT SMALL LINEAR THERMOELECTRIC ACTUATORS
Position Indicator
The position indicator (the red indicator behind the window on the face of the actuator) shows the model's type of action (NO or NC) as well as the current stroke position.
NC
NO
Fig. Position indicator
WIRING
grün, vert, verde, green, zielony grün, vert, verde, green, zielony braun, brun, marrone, brown, brazowy
MTx-xxxS
230 Vac / 24 V
5 A (3)
R-T
230 Vac / 24 V
3W
blau, bleu, blu, blue, niebieski
MTx-xxx, MTx-xxxLC
braun, brun, marrone, brown, brazowy
R-T
230 Vac / 24 V
3W (MTx-xxxLC: 2 W)
blau, bleu, blu, blue, niebieski
Fig. [. . . ] Actual function can vary depending upon the individual type of valve.
Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Rolle, Z. A. La Pièce 16, Switzerland by its Authorized Representative:
Automation and Control Solutions Honeywell GmbH Böblinger Strasse 17 71101 Schönaich Germany Phone: (49) 7031 63701 Fax: (49) 7031 637493 http://ecc. emea. honeywell. com Subject to change without notice. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL MT8-024 Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL MT8-024 will begin.