User manual HONEYWELL PTI-610

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL PTI-610. We hope that this HONEYWELL PTI-610 user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL PTI-610.


Mode d'emploi HONEYWELL PTI-610
Download

You may also download the following manuals related to this product:

   HONEYWELL PTI-610 DATASHEET (284 ko)

Manual abstract: user guide HONEYWELL PTI-610

Detailed instructions for use are in the User's Guide.

[. . . ] All devices have been checked by the manufacturer concerning safety regulations according to EN 60335-1 (DIN VDE 0700 T500). This temperature display is designed to indicate room and medium temperatures for general-purpose applications but in particular for freezer chests and cooling rooms. Any variation from this or other use will not comply with the requirements. [. . . ] Possible damage must be announced immediately in writing, within 8 days at the latest (see Delivery and Payment Terms § 7). Before disposing the packaging, please check for loose functional parts and information leaflets. For processing warranty claims, please give an exact description of the defect (possibly with a photo) and state the model designation of the device. Fasten room sensor T1 at suitable position by means of a cable grip. Subject to change without notice · Only professionals may work on electrical systems. 1 Start-up The display of temperature is started by connecting the power supply to the binders 1 and 2 (see chapter 6. 2 Display The display indicates the room temperature, measured with room sensor T1 in °C or °F depending on the selected display parameter (see chapter 7. 3 Error message deviation of measuring range Do not feed power supply at the sensor input. The maximum length of the sensor cable is 20 m, with a minimum cross section 2 of 2 x 0. All shields must be laid at the side of the control unit onto an earthing/protective potential. the extension cable shield must not be connected on the sensor side to avoid equipotential bonding currents via the shielding. Pay attention to the operative range of the sensor cable: ­ 40 °C to +80 °C fixed cable laying ­ 30 °C to +80 °C loose cable laying The measuring range of the PTI 610 lies between -55 °C and + 99 °C. The display automatically returns to the standard display as soon as there is no limit error anymore. 4 Alert If the sensor breaks down due to a short circuit or an interruption PF1 is displayed. To return to the standard display after eliminating the error the device must be disconnected from the power supply for a short time. Subject to change without notice · 5 Device parameter The electronic temperature display has three parameter Parameter: d1 d19 d22 Value: 0 or 32 -20 to +20 0 or 1 Description: system parameter (can not be changed by operator) temperature offset in Kelvin 0: display in °C 1: display in °F Subject to change without notice · 6 Changing to the parameter level Behind the front foil of the temperature display device there are 3 keys which are used within the parameter level. The keys are protected against maloperation · Deactivate key lock press + and - key approx. Activate key lock press + and - key approx. [. . . ] Damage or malfunction caused by improper handling or non-compliance of the installation and operating instructions are not covered by the warranty. The warranty expires if any work is carried out on the system structure. Technical Data Nominal power supply / frequency Nominal power input Measuring range Display Resolution Display accuracy Sensor input: - Cable length of sensors - Operative range of cables - Accuracy of sensors Connectors Tightening torque Ambient temperature/ humidityation in operation in storage Protective system: housing operator's panel Material of housing Dimensions of housing Weight 230 V, ±10%, 50/60 Hz 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL PTI-610

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL PTI-610 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag