[. . . ] Heating Controller SDC Remote Heating Controller DHC
OPERATING INSTRUCTIONS
EN2H-0220GE51 R0308
EN2H-0220GE51 R0308
SDC / DHC
Contents
Contents
1 2 Software version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Safety instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2. 1 2. 2 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Requirements for start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] 24 and 4. 2. 2 "Timeprograms" menu, pg. 34.
Pos: 20 /156-Honeywell/Bedienung/Urlaubsbetrieb @ 1\m od_1207644072619_6. doc @ 9315
EN2H-0220GE51 R0308
23
Operation
SDC / DHC
4. 1. 2. 6. 1
Holiday mode In holiday mode, the heating circuits can be switched off and protected from frost or operated based on the settings for the RED. HEATING operating mode for the duration of the holiday based on the presetting ("Direct circuit" or "Mixed heating circuit 1" / "Mixed heating circuit 2" menu, parameter 25 = holiday operating mode).
Setting
Press button. The menu-selection level Switching time programs / Holiday programs appears in the display. The day on which the holiday is to begin flashes in the display. Set the day the holiday will begin with the input button . Set the day you will return from holiday with the input button . You can now enter additional holiday timeframes (up to 15 holiday blocks).
Application
Longer absence while heating operation is active.
24
EN2H-0220GE51 R0308
SDC / DHC
Operation
Control during holidays
At outside temperatures below the frost-protection limit (see 4. 2. 3 "System Parameters" menu, pg. 51) the heating circuits are controlled as follows: Without wall devices: Based on a lowered room temperature specification of 3 C. With wall devices: Based on the room frost-protection limit of the respective heating circuit of 10 C (see "Direct Heating Circuit" or "Mixed Heating Circuit 1", "Mixed heating circuit 2" menu, parameter 08 = room frost-protection limit).
Cancellation
An active holiday program can be cancelled in case of early return. Press button.
Turn input button and switch to automatic mode. The active holiday program has been cancelled. Factory setting Setting range Display Current date Current date. . . (current date + 250 days) An active holiday program appears in the basic display with information on the return date.
Pos: 21 /156-Honeywell/Bedienung/Taste_Anlageninform ation @ 1\m od_1207644494728_6. doc @ 9450
EN2H-0220GE51 R0308
25
Operation
SDC / DHC
4. 1. 2. 7
"System information" button Calls up system information, such as temperatures and counter data. The information on the outside temperature appears first after the
button is pressed. Turning the input button causes the
system temperatures and the counter and consumption states and operating states of the connected system components to appear. Pressing the input button causes the respective setpoint values to appear. Exceptions Collector flow temperature: Solar tank temperature: Outside temperature: NOTE No setpoint No setpoint Averaged value
The displayed information (see the following example) is independent of the installed or enabled system components and control circuits.
26
EN2H-0220GE51 R0308
SDC / DHC
Operation
Operating overview
Press Turn input button to the left
button Turn input button to the right
Average/current outside temperature value
Program/operating mode direct heating circuit/pump status
Outside temperature min. (0:00 to 24:00 hours)
Program/operating mode mixed heating circuit 1/pump status
Heat generator temperature setpoint/actual value
Actuator of mixed heating circuit 1/status
Hot-water temperature setpoint/actual value
Program/operating mode mixed heating circuit 2/pump status
Flow temperature setpoint/actual value
Actuator of mixed heating circuit 2/status
Flow temp of mixed heating circuit 1 setpoint/actual value
Program/operating mode hot-water circuit/pump status
Flow temp of mixed heating circuit 2 setpoint/actual value
Heat generator status
Variable input 1 setpoint/actual value
Direct heating circuit pump function/status
Variable input 2 setpoint/actual value
Variable output 1 function/operating state
Variable input 2 setpoint/actual value
Variable output 2 function/operating state
Operating hours
Activations of heat generator
EN2H-0220GE51 R0308
27
Operation
SDC / DHC
Setting time for automatic return
If the button is pressed and held for approx. With this parameter, the time it takes for automatic return to the basic display can be specified.
Setting range
OFF
No return. The last selected information display continuously remains in the basic display until the next change. Automatic return from the information level after the specified time (in 0. 5 minute increments).
1 . . . [. . . ] The maximum heat generator temperature is not functional. The heating circuit pump is switched off after a delay to avoid safety deactivation by reheating the heat generator (pump follow-up). If the outside temperature is or becomes lower than the specified outside temperature frost-protection limit, the controller switches from deactivated (deactivation mode) to lowered lowering operation and controls the heating circuit temperature based on the set lowering curve taking the set minimum heat generator specification into account. Application NOTE Building with high insulation values (full heating protection). [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL SDC
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.