User manual HONEYWELL SDC

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL SDC. We hope that this HONEYWELL SDC user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL SDC.


Mode d'emploi HONEYWELL SDC
Download

You may also download the following manuals related to this product:

   HONEYWELL SDC MANUAL 2 (533 ko)
   HONEYWELL SDC QUICK GUIDE (528 ko)
   HONEYWELL SDC INSTALLATION INSTRUCTIONS (3684 ko)

Manual abstract: user guide HONEYWELL SDC

Detailed instructions for use are in the User's Guide.

[. . . ] Heating Controller SDC Remote Heating Controller DHC OPERATING INSTRUCTIONS EN2H-0220GE51 R0308 EN2H-0220GE51 R0308 SDC / DHC Contents Contents 1 2 Software version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Safety instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2. 1 2. 2 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Requirements for start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] 24 and 4. 2. 2 "Timeprograms" menu, pg. 34. Pos: 20 /156-Honeywell/Bedienung/Urlaubsbetrieb @ 1\m od_1207644072619_6. doc @ 9315 EN2H-0220GE51 R0308 23 Operation SDC / DHC 4. 1. 2. 6. 1 Holiday mode In holiday mode, the heating circuits can be switched off and protected from frost or operated based on the settings for the RED. HEATING operating mode for the duration of the holiday based on the presetting ("Direct circuit" or "Mixed heating circuit 1" / "Mixed heating circuit 2" menu, parameter 25 = holiday operating mode). Setting Press button. The menu-selection level Switching time programs / Holiday programs appears in the display. The day on which the holiday is to begin flashes in the display. Set the day the holiday will begin with the input button . Set the day you will return from holiday with the input button . You can now enter additional holiday timeframes (up to 15 holiday blocks). Application Longer absence while heating operation is active. 24 EN2H-0220GE51 R0308 SDC / DHC Operation Control during holidays At outside temperatures below the frost-protection limit (see 4. 2. 3 "System Parameters" menu, pg. 51) the heating circuits are controlled as follows: Without wall devices: Based on a lowered room temperature specification of 3 C. With wall devices: Based on the room frost-protection limit of the respective heating circuit of 10 C (see "Direct Heating Circuit" or "Mixed Heating Circuit 1", "Mixed heating circuit 2" menu, parameter 08 = room frost-protection limit). Cancellation An active holiday program can be cancelled in case of early return. Press button. Turn input button and switch to automatic mode. The active holiday program has been cancelled. Factory setting Setting range Display Current date Current date. . . (current date + 250 days) An active holiday program appears in the basic display with information on the return date. Pos: 21 /156-Honeywell/Bedienung/Taste_Anlageninform ation @ 1\m od_1207644494728_6. doc @ 9450 EN2H-0220GE51 R0308 25 Operation SDC / DHC 4. 1. 2. 7 "System information" button Calls up system information, such as temperatures and counter data. The information on the outside temperature appears first after the button is pressed. Turning the input button causes the system temperatures and the counter and consumption states and operating states of the connected system components to appear. Pressing the input button causes the respective setpoint values to appear. Exceptions Collector flow temperature: Solar tank temperature: Outside temperature: NOTE No setpoint No setpoint Averaged value The displayed information (see the following example) is independent of the installed or enabled system components and control circuits. 26 EN2H-0220GE51 R0308 SDC / DHC Operation Operating overview Press Turn input button to the left button Turn input button to the right Average/current outside temperature value Program/operating mode direct heating circuit/pump status Outside temperature min. (0:00 to 24:00 hours) Program/operating mode mixed heating circuit 1/pump status Heat generator temperature setpoint/actual value Actuator of mixed heating circuit 1/status Hot-water temperature setpoint/actual value Program/operating mode mixed heating circuit 2/pump status Flow temperature setpoint/actual value Actuator of mixed heating circuit 2/status Flow temp of mixed heating circuit 1 setpoint/actual value Program/operating mode hot-water circuit/pump status Flow temp of mixed heating circuit 2 setpoint/actual value Heat generator status Variable input 1 setpoint/actual value Direct heating circuit pump function/status Variable input 2 setpoint/actual value Variable output 1 function/operating state Variable input 2 setpoint/actual value Variable output 2 function/operating state Operating hours Activations of heat generator EN2H-0220GE51 R0308 27 Operation SDC / DHC Setting time for automatic return If the button is pressed and held for approx. With this parameter, the time it takes for automatic return to the basic display can be specified. Setting range OFF No return. The last selected information display continuously remains in the basic display until the next change. Automatic return from the information level after the specified time (in 0. 5 minute increments). 1 . . . [. . . ] The maximum heat generator temperature is not functional. The heating circuit pump is switched off after a delay to avoid safety deactivation by reheating the heat generator (pump follow-up). If the outside temperature is or becomes lower than the specified outside temperature frost-protection limit, the controller switches from deactivated (deactivation mode) to lowered lowering operation and controls the heating circuit temperature based on the set lowering curve taking the set minimum heat generator specification into account. Application NOTE Building with high insulation values (full heating protection). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL SDC

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL SDC will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag