[. . . ] SM150 Diaphragm safety valve for closed heating systems Product specification sheet Application Membrane safety valves of this type are used to protect closed hot drinking water systems according to DIN 1988 and DIN 4753-1. [. . . ] If the opening force exceeds the force exerted by the spring, then the valve disc is lifted off the valve seat and the valve discharges the medium. In accordance with the requirements of the standard, the full discharge capacity of the valve will be achieved when the system pressure climbs to no more than 10% above the set pressure of the valve. Full shutoff must be achieved if the system pressure falls to below 80% of the nominal set pressure of the valve. For valves rated up to 3. 0 bar, the closing pressure can be taken as 0. 6 bar minimum. SM150- 1/2ZA T SM150- 1/2ZB SM150- 1/2ZC SM150- 1/2A SM150- 1/2B SM150- 1/2C SM150- 3/4ZA SM150- 3/4ZB SM150- 3/4ZC SM150- 3/4A SM150- 3/4B SM150- 3/4C Set pres- Connection size Connection size sure Inlet Outlet 6. 0 bar 8. 0 bar 10. 0 bar 6. 0 bar 8. 0 bar 10. 0 bar 6. 0 bar 8. 0 bar 10. 0 bar 6. 0 bar 8. 0 bar 10. 0 bar Rp1/2" IG Rp1/2" IG Rp1/2" IG Rp1/2" IG Rp1/ 2" H ROutlet RInlet Rp1/2" IG Rp1/2" IG Rp1/2" IG Rp3/4" IG Rp3/4" IG Rp3/4" IG Rp3/4" IG Rp3/4" IG Rp3/4" IG Rp1" IG Rp1" IG Rp1" IG IG Rp1/2" IG Rp3/4" IG Rp3/4" IG Rp3/ Rp3/ 4" IG IG Rp3/4" IG 4" Rp3/4" IG Connection size Inlet Connection size Outlet Dimensions Only the products with an outlet diameter larger than the inlet diameter are TÜV-certified. 2 www. honeywell. com GE0H-1367GE23 R0609 · Subject to change Weight For water heaters with capacity (litres) Maximum permissible heat input (kW) TÜV Approval Nos. . . * valid Approval No. R R (mm) H Do T g 1/ 1/ 2" IG " IG 2 3/ 3/ IG " IG 4 4" 1/ 3/ IG " IG 4 2" 3/ 4" IG 1" IG 60 33 32 135 up to 200 50 - 62 33 46 145 up to 1000 100 - 62 60 36 33 46 46 140 150 up to 200 up to 1000 50 100 TÜV · SV · . . * - 2017· 13 · W · p SM150 Diaphragm safety valve Installation Example Installation Guidelines · · Safety valve must be installed in the cold water supply pipework before the water heater The installation must be carried out so that: o There are no shutoff valves or fittings, narrowing of the pipework or strainers between the water heater and the safety valve o good access is provided for service and maintenance o that the safety valve is positioned above the heat generator o that between the safety valve and heat exchanger a max. 1 m long straight connection line with the size of the inlet diameter is installed The safety valve must be mounted so that in its installed condition no external forces act on it The discharge line must be performed to the size of the safety valve outlet diameter and may not have more than 2 elbows and or be longer than 2m The discharge line must be installed with an incline Typical Applications Membrane safety valves are installed according to their specification upstream from heat generators. The following are some typical applications: · · Central hot water supply systems Hot water storage units · · · GE0H-1367GE23 R0609 · Subject to change Maintenance In accordance with DIN 1988, Part 8, the following operations should be carried out regularly. [. . . ] La Pièce 16, Switzerland by its Authorised Representative Honeywell GmbH GE0H-1367GE23 R0609 Subject to change without notice © 2009 Honeywell GmbH [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL SM150

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL SM150 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag