[. . . ] SINGLE- AND DUAL-STAGE INDUSTRIAL ROOM THERMOSTATS
SPECIFICATION DATA AND MOUNTING INSTRUCTIONS
T6120A, B
GENERAL
The T6120A and B Single- and Dual-Stage Industrial Room Thermostats are designed for measuring, monitoring, and controlling temperatures in heating and cooling systems. These thermostats are suitable for the following areas of applications: · commercial buildings, · storage rooms, · garages, · machine rooms, · factories, · greenhouses, and · agricultural installations.
FEATURES
· · · · Liquid-filled stainless steel or copper (T6120A1005, only) bulb. Easy installation and wiring connection. [. . . ] When the temperature rises, the contact will open (see Fig. To control a cooling unit, connect the red terminal ("COMMON") and white terminal ("NORM CLOSED") of the thermostat to the cooling unit. When the temperature drops, the contact will open (see Fig. 3).
2
3
1 red blue white
T T
Fig. Wiring T6120A1013/1021/1039 and T6120B1003
Adjusting the Hysteresis (T6120A1013/A1021, only)
PG 13. 5 105 70 52
90 108
In the case of the T6120A1013/A1021 Single-Stage Thermostats, it is possible to adjust the hysteresis to a value of between 2 K (factory setting) and 15 K. This can be done as follows: Pull off the adjustment knob, unscrew the two fastening screws, and remove the housing cover. The hysteresis adjustment dial is now visible (see Fig. The dial settings are numbered from "2" (corresponding to the min. setting of 2 K) to "15" (corresponding to the max. Dimensions T6120A1005 (in mm)
increasing hysteresis (max. : 15 K)
decreasing hysteresis (min. : 2 K)
Fig. Adjusting the hysteresis (T6120A1013/A1021, only)
EN0B-0317GE51 R0304
2
T6120A, B SINGLE- AND DUAL-STAGE INDUSTRIAL ROOM THERMOSTATS
Dimensions
PG 11
stage 1
stage 2
70
26 52
red
blue
white
red
blue
white
90 108 150
T
86 72
Fig. Wiring T6120B1003
20
Adjusting the Switching Differential between Stages
In the case of the T6120B1003 Dual-Stage Thermostat, it is possible to adjust the switching differential (i. e. the difference in temperatures at which the two stages are activated) to a value of between 2 K (factory setting) and 10 K. This can be done as follows: Pull off the adjustment knob, unscrew the two fastening screws, and remove the housing cover. [. . . ] Adjusting the switching differential
3
EN0B-0317GE51 R0304
T6120A, B SINGLE- AND DUAL-STAGE INDUSTRIAL ROOM THERMOSTATS
Automation and Control Solutions Honeywell GmbH P. O. Box 1254 D-71099 Schönaich Phone: (49) 7031-637-02 Fax: (49) 7031-637-850 http:/honeywell. de/fema Subject to change without notice. Printed in Germany EN0B-0317GE51 R0304 Manufacturing location certified to [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL T6120B
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL T6120B will begin.