User manual HONEYWELL T7416A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL T7416A. We hope that this HONEYWELL T7416A user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL T7416A.


Mode d'emploi HONEYWELL T7416A
Download
Manual abstract: user guide HONEYWELL T7416A

Detailed instructions for use are in the User's Guide.

[. . . ] OUTSIDE AIR TEMPERATURE SENSOR T7416A PRODUCT DATA FEATURES · Available with different temperature sensing element: Pt 1000, NTC 20k and NTC 10k · Wide sensing range · High accuracy Models OS no. [. . . ] The resistor sensing element changes its resistance value according to the temperature. SPECIFICATION Ambient Limits Transport and storage temperature Humidity Safety Protection standard terminal box and tube Dimensions Weight -40. . . . +70 °C (-40. . . +158 °F) 5. . . 95%rh, non-condensing IP54 as per EN60529 See page 2 60 g Temperature Sensor sensing element Pt 1000 NTC 20k NTC 10k -40 . . . . +70°C (-40 . . . +158°F) temperature sensing range nominal value 1000 at 0°C 20 k at 25°C 10 k at 25°C sensitivity 3. 85 / K nonlinear accuracy DIN IEC751 Class B T/K = 0. 3 + 0. 005 · t (t = °C) 0. 3 K at 25°C response time 0. 5 7 min ® U. S. Registered Trademark Copyright © 2008 Honeywell Inc. · All rights reserved EN0B-0283GE51 R0208 T7416A OUTSIDE TEMPERATURE SENSOR DIMENSIONS 49 (1. 93) 37 (1. 47) sensor Two mounting holes 4 mm in diameter for 3. 5-mm (0. 138") diameter screws 53 (2. 09) 72 (2. 8) 38 (1. 50) Case hole diameter allows Pg9 cable entry. terminal Fig. Dimensions in mm (inches) INSTALLATION wiring run sensor to controller maximum length 200 m (660 ft) Offset of Pt 1000 sensor due to wire resistance per 10 m distance from sensor to controller; NTC sensor negligible: type of wire 0. 5 mm (AWG20) 1. 0 mm (AWG17) 1. 5 mm (AWG15) 2 2 2 cable entry Fig. Interior temperature offset 0. 18 °C (0. 324 °F) 0. 09 °C (0. 162 °F) 0. 06 °C (0. 108 °F) NOTE: Use shielded wiring in areas with high EMI. [. . . ] Keep 15 cm (5. 9'') minimum distance between sensor lines and 230 Vac power lines. Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Ecublens, Route du Bois 37, Switzerland by its Authorized Representative: Automation and Control Solutions Honeywell GmbH Böblinger Straße 17 D-71101 Schönaich Phone: (49) 7031 63701 Fax: (49) 7031 637493 http://ecc. emea. honeywell. com Subject to change without notice. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL T7416A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL T7416A will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag