Manual abstract: user guide HONEYWELL TBEDATASHEET
Detailed instructions for use are in the User's Guide.
[. . . ] <
Series TBE
THERMOSTATIC EXPANSION VALVES FIXED ORIFICE, FLARE CONNECTIONS
PRODUCT DATA
Features
· TBE: with internal pressure equalisation; for single injection in installations with one or more cooling circuits. · TBEX: with external pressure equalisation; for optimal evaporation effectiveness in all applications. [. . . ] Thermal systems with adsorber charge are completely insensitive to effects of temperature on the capillary tube and valve head. It reacts only according to the temperature of the bulb. Thus, Honeywell TBE(X) valves with combi adsorber charge work absolutely reliable, even in icy condition or while defrosting using hot gas. Adsorber charge with pressure limiting performance (MOP) Refrigerant R134a, R401A, R12 R22, R407C, R407A, R422D R404A, R507A, R402A, R407B, R502 Evaporation temperature range +5 °C to -30 °C -10 °C to -30 °C +5 °C to -45 °C -10 °C to -45 °C -27 °C to -45 °C -10 °C to -50 °C -20 °C to -50 °C -27 °C to -50 °C MOP PS
(bar(a))
PF
(bar(a))
MOP A +15 °C MOP A ±0 °C MOP A +15 °C MOP A ±0 °C MOP A -18 °C MOP A ±0 °C MOP A -10 °C MOP A -18 °C
34 29 36 29 29 36 34 34
37. 4 31. 9 39. 6 31. 9 31. 9 39. 6 37. 4 37. 4
Further refrigerants and MOP on request
Capacities
Type Orifice size 0. 5 0. 7 1. 0 TBE TBEX 1. 5 2. 0 2. 5 3. 0 3. 5 4. 5 Nominal capacity (kW)* R134a 0. 69 1. 0 1. 4 2. 2 2. 9 4. 0 6. 6 8. 7 11. 8 R22 0. 99 1. 4 2. 0 3. 2 4. 0 5. 8 9. 3 12. 2 17. 0 R407C 0. 95 1. 3 1. 9 3. 1 3. 9 5. 6 8. 9 11. 7 16. 4 R422D 0. 67 0. 92 1. 3 2. 2 2. 7 3. 9 6. 3 8. 3 11. 3 R404A 0. 68 0. 97 1. 4 2. 2 2. 8 4. 1 6. 5 8. 6 12. 0 R507A 0. 69 0. 98 1. 4 2. 3 2. 9 4. 1 6. 6 8. 7 12. 1
* Capacities are based on t0 = +4 °C, tc = +38 °C and 1 K subcooled liquid refrigerant entering the valve. For other operating conditions see capacity charts in Honeywell catalogue or consult the Honeywell software.
EN0H-1906GE23 R0709
2
Honeywell GmbH · Subject to change without notice
SERIES TBE
Dimensions and Weights
Connections Type Two-way construction Angle construction Inlet (A) 5/8" UNF 3/4" UNF Outlet (B) 3/4" UNF 7/8" UNF Pressure equalisation (C) 7/16" UNF 7/16" UNF D 47. 5 42. 5 E 40 Dimensions (mm) F 51. 5 46. 5 G 38 40 H 43 I 29 29 Weight (kg) approx. 0. 34
Connection = size of UNF thread
TBE(X) 0. 5 - 4. 5 two-way
TBE(X) 0. 5 - 4. 5 angle
Type Code / Order Information
TBE Series Pressure equalisation: X = external () = internal Orifice size Refrigerant Charge type, MOP, evaporation temperature range Flare connection UNF (inlet x outlet) D = two-way construction W = angle construction X 4. 5 R134a MOP A +15 °C 5/8" x 3/4" D
Honeywell GmbH · Subject to change without notice
3
EN0H-1906GE23 R0709
SERIES TBE
Installation
· The valves may be installed in any position. · The external pressure equaliser line (TBEX) should be 6 mm or 1/4" in diameter and is to be connected downstream of the remote bulb. An overbow is recommended in order to prevent the ingress of oil into the equaliser line. · The bulb should preferably be positioned on the upper half of a horizontal suction line but never after a liquid trap. As a general rule, bulbs of expansion valves should be insulated to prevent them being affected by the ambient temperature. [. . . ] With TBEX angle construction there is no superheat setting in built-in condition possible, use factory setting.
Automation and Control Solutions Honeywell GmbH Hardhofweg 74821 Mosbach/Germany Phone: +49 (0) 62 61 / 81-475 Fax: +49 (0) 62 61 / 81-461 E-Mail: cooling. mosbach@honeywell. com www. honeywell-cooling. com
EN0H-1906GE23 R0709 4
Manufactured for and on behalf of the Environment and Combustion Controls Division of Honeywell Technologies Sàrl, 1180 Rolle, Z. La Pièce 16, Switzerland by its authorized representative Honeywell GmbH
KAT-TBE-002
Honeywell GmbH · Subject to change without notice [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL TBE
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.