Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL TD2400. We hope that this HONEYWELL TD2400 user guide will be useful to you.
Lastmanuals help download the user guide HONEYWELL TD2400.
Detailed instructions for use are in the User's Guide.
[. . . ] Programmable Thermostat
by Duracraft
OWNER'S GUIDE
Weekday/Weekend (5-day/ 2-day) Programmable Heat and/or Cool Low Voltage (20 to 30 Vac) Thermostat and Mounting Plate Model TD2400
1
69-1120
Welcome to the world of comfort and energy savings with your new Duracraft Programmable Thermostat. Your new thermostat will automatically control the temperature in your home, keeping you comfortable while saving energy when programmed according to the instructions in this manual. Direct any questions concerning the application of this thermostat to Duracraft Consumer Services at 1-800-554-4558, Monday-Friday 7:00 a. m. -5:30 p. m. , Eastern time.
RECYCLING THERMOSTAT
If this thermostat is replacing a thermostat that contains mercury in a sealed tube, do not place your old thermostat in the trash. Contact your local waste management authority for instructions regarding recycling and the proper disposal of your old thermostat. [. . . ] The system on-time should be optimized according to the type of system to minimize room temperature swings. Setting the screw "out one turn" means turning the screw approximately 360° counterclockwise, or about one complete turn. In the unlikely event that you want a longer furnace on-time, readjust screws A and/or B as follows:
18
69-1120
First, turn in both screws completely, then adjust for system type: · Warm Air Furnace--Set at the Hot Water setting (A--out one turn, B--leave in). · Electric Furnace--Leave at the Warm Air Furnace setting (A--leave in, B--leave in). NOTE: This thermostat does not have a setting for steam/gravity air. Cycles would not be long enough for accurate temperature control. IMPORTANT When using a high efficiency furnace such as a 90% or greater AFUE (Average Fuel Utilization Efficiency) unit, adjust screw A out one turn and leave screw B in.
19
u The thermostat is set to read the temperature in degrees Fahrenheit. If readings are desired in degrees Celsius, adjust screw C out one turn, as shown in illustration.
THERMOSTAT BACK
A
DISPLAY °F CIN DISPLAY °C COUT 1 TURN
C
ADJUST SCREWS THROUGH HOLES TO SELECT OPERATION DESIRED FUEL SWITCH HEATING SYSTEM POSITION F WARM AIR AIN BIN FURNACE F HOT WATER AOUT BIN BOILER 1 TURN E ELECTRIC AIN BOUT FURNACE 1 TURN
B
D
W
FOR HIGH EFFICIENCY FURNACE (90%+ AFUE) ADJUST: SCREW AOUT ONE TURN SCREW BIN FUEL SWITCH F POSITION
Y
G
FUEL SWITCH
F
E
R
Rc
M8796
69-1120
Step 7. Mount Thermostat Mounting Plate
u Position mounting plate on wall. Use level to make sure mounting plate is level. Use a pencil to mark the two mounting holes. u Remove mounting plate from wall, and drill 3/16-inch holes in wall (if drywall) as marked. For firmer material such as plaster or wood, drill WALL ANCHORS (2) WIRES THROUGH 7/32-inch WALL OPENING holes. Gently WALL tap anchors (provided) into drilled holes MOUNTING PLATE until flush with the wall.
MOUNTING SCREWS (2)
M1718
u Reposition mounting plate over holes, pulling wires through wiring opening. Loosely insert two mounting screws into holes. u Level for appearance only; thermostat will function properly even when not level. Tighten mounting screws.
LEVEL
M1714A
20
69-1120
Step 8. Wire Thermostat Terminals
NOTE: All wiring must comply with local codes and ordinances. If unsure about household wiring procedures, call your local heating/air conditioning contractor. Refer to masking tape labels you placed on wires when you removed your old thermostat. u Match the letter of your old thermostat wire with the terminal of the corresponding letter on the back of your new thermostat. Refer to illustrations on pages 23 and 24. [. . . ] Be aware that it is normal for the current setting and display temperature to differ on occasion. During recovery from setback or setup, setting and display temperatures may differ for up to 30 minutes after recovery period.
33
69-1120
Incorrect room temperature showing on thermostat display.
Make sure the hole behind the thermostat is plugged with insulation to help prevent drafts from adversely affecting the thermostat operation. The thermostat is factory-calibrated and cannot be adjusted.
Toll-free Customer Assistance
For all questions concerning this thermostat, please read and follow the instructions. If additional assistance is needed, call Duracraft Consumer Services toll-free at 1-800-554-4558, Monday Friday, 7:00 a. m. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL TD2400
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL TD2400 will begin.