User manual HONEYWELL V320 VENUS SERIES TRV DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL V320 VENUS SERIES TRV. We hope that this HONEYWELL V320 VENUS SERIES TRV user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL V320 VENUS SERIES TRV.


Mode d'emploi HONEYWELL V320 VENUS SERIES TRV
Download
Manual abstract: user guide HONEYWELL V320 VENUS SERIES TRVDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] TRV BODY WITH STROKE LIMITATION, INTERNAL THREADS PRODUCT DATA V320 VENUS Series TRV Body Application Thermostatic radiator valve bodies (TRV bodies) are fitted on the supply or return of radiators or heat exchangers. Together with a radiator thermostat, for example the Thera-4, they control the room temperature by regulating the flow of hot water into the radiator. [. . . ] 120°C (248°F) Thermostat connection M30 x 1. 5 Closing dimension Stroke Honeywell Subject to change EN0H-2117GE25 R1106 V320 - VENUS SERIES TRV BODY Function Thermostatic radiator valves enable individual control of room temperature and thus save energy. The TRV body is controlled by the radiator thermostat. Air from the room passing over the sensor of the radiator thermostat causes the sensor to expand when the temperature rises. The sensor acts onto the valve spindle and this causes the TRV body to close. When the temperature falls the sensor contracts and the spring-loaded valve spindle is opened. The TRV opens in proportion to the temperature of the sensor. Only the amount of water required to maintain the room temperature set on the radiator thermostat can flow into the radiator. Please Note: · To avoid stone deposit and corrosion the composition of the medium should conform with VDI-Guideline 2035 · Additives have to be suitable for EPDM sealings · System has to be flushed thoroughly before initial operation with all valves fully open · Any complaints or costs resulting from non-compliance with above rules will not be accepted by Honeywell · Please contact us if you should have any special requirements or needs Setting procedure Turn the pre-setting screw until stop. Mark position of screwdriver slot as reference point. Then turn anticlockwise according to reference figure obtained from the pressure drop chart. Reference figure 10 corresponds to 1 turn. [. . . ] V320ESLGB10 V320ESLGB15 V320DSLGB10 V320DSLGB15 V320RSLGB15 All dimensions in mm unless stated otherwise. Accessories Connections Compression ring and nut 3/8" x 10 mm 3/8" x 12 mm 1/2" x 10 mm 1/2" x 12 mm 1/2" x 14 mm 1/2" x 15 mm 1/2" x 16 mm NOTE: VA620A1010 VA620A1012 VA620A1510 VA620A1512 VA620A1514 VA620A1515 VA620A1516 Pressure cap ­ for shutting off valves on radiator oulet for valves DN10 (3/8") for valves DN15 (1/2") Sealing ring for pressure cap for valves DN10 (3/8") for valves DN15 (1/2") Service tool to replace valve insert for all sizes VA8200A001 VA5090A010 VA5090A015 VA2202A010 VA2202A015 Handwheel Pack of 10 pieces H100-1/2D Service Parts Valve insert VS1200SLGB01 Support inserts have to be used for copper or soft steel pipe with 1. 0 mm wall thickness 3/8" x 12 mm 1/2" x 12 mm 1/2" x 15 mm 1/2" x 16 mm VA621A1012 VA621A1512 VA621A1515 VA621A1516 Compression ring and nut with support insert (2 pcs each) Compression ring and nut with support insert for composite pipe (2 pcs each) 1/2" x 14 mm 1/2" x 16 mm VA622B1514 VA622B1516 Honeywell Subject to change 3 EN0H-2117GE25 R1106 V320 - VENUS SERIES TRV BODY Flow Diagram 1K 2K 3K Pre-setting kvs(cv)-values for DN10 kvs(cv)-values for DN15 NOTE: 1 2 3 4 5 7 17. 5 = open = kvs 0. 25 (0. 29) 0. 50 (0. 59) 0. 70 (0. 82) 1. 00 (1. 17) 1. 25 (1. 46) 1. 50 (1. 76) 1. 70 (1. 95) 0. 25 (0. 29) 0. 50 (0. 59) 0. 70 (0. 82) 1. 00 (1. 17) 1. 25 (1. 46) 1. 50 (1. 76) 1. 85 (2. 16) Pre-settings above 4 are unsuitable for operation with radiator thermostats and should only be used with actuators (open/ close operation). Automation and Control Solutions Honeywell GmbH Hardhofweg 74821 Mosbach, Germany Phone: +49 (6261) 810 Fax: +49 (6261) 81393 www. honeywell. com EN0H-2117GE25 R1106 November 2006 © 2006 Honeywell International Inc. Subject to change · All rights reserved Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Ecublens, Route du Bois 37, Switzerland or by its Authorized Representative. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL V320 VENUS SERIES TRV

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL V320 VENUS SERIES TRV will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag