User manual HONEYWELL V5013E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL V5013E. We hope that this HONEYWELL V5013E user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL V5013E.


Mode d'emploi HONEYWELL V5013E
Download
Manual abstract: user guide HONEYWELL V5013E

Detailed instructions for use are in the User's Guide.

[. . . ] EXTERNAL THREADED END-CONNECTION LINEAR VALVE PN16 PRODUCT DATA V5013E FEATURES · · · · · · Brass body with external threaded end connections Low seat leakage rate Self-adjusting packing Accurate positioning to ensure state-of-the-art temperature control Directly-coupled electric and pneumatic actuators for easy mounting Constant total flow throughout full plug travel SPECIFICATIONS Action: Nominal pressure rating: Flow characteristic: Rangeability: Leakage rate: Stroke: Valve body: Pipe connections: Material: Dimensions: Trim: Seat: Plug: Stem: Packing: Stem up to close port A-AB PN16 equal percentage: port A-AB linear: port B-AB 50:1 0. 05% of kvs 20 mm External threading as per ISO228 Brass See Fig. [. . . ] The installation of a strainer is strongly recommended. The valve should be installed as stress-free as possible. SPARE PARTS Repair packing kit, DN15. . . 50: Order number 0901787 CLOSE-OFF PRESSURE RATINGS Electric Actuators actuator type ML6420 / ML6425 ML7420 / ML7425 M6421 / M7421 force 600 N 1800 N DN15 1600 DN20 1600 Table 2. Close-off pressure ratings (in kPa) of electric actuators valve size DN25 1000 1600 DN32 700 1600 DN40 460 1500 DN50 260 850 Pneumatic Actuators MP953 Table 3. Close-off pressure ratings (in kPa) of pneumatic actuators MP953 actuator type MP953C5001 MP953C5027 MP953A5005 MP953C5019 MP953C5068 MP953C5084 MP953A5039 MP953C5076 MP953D5025 MP953D5009 MP953B5003 spring range 14. . . 48 kPa 27. . . 76 kPa 55. . . 83 kPa 14. . . 48 kPa 27. . . 76 kPa 55. . . 83 kPa 27. . . 76 kPa 55. . . 83 kPa lower upper 0 kPa 115 kPa upper lower air closed seat pressure DN15 150 1600 800 1150 1600 860 1550 1600 1600 1600 1600 1600 1600 1600 1600 1600 DN20 --310 530 950 380 650 1600 1550 1600 1600 1600 840 1480 1050 1490 valve size DN25 --180 350 620 240 420 1600 1030 1500 1600 1190 570 990 720 1490 DN32 --90 200 370 130 240 1600 630 950 1470 750 340 600 440 920 DN40 --30 100 220 60 130 1130 400 600 970 460 200 370 260 600 DN50 ------50 630 200 320 520 250 90 190 130 320 EN0B-0446GE51 R0407 2 V5013E ACCESSORIES Valves V5013E require the use of three connection sets. connection pipe size G 1/2" G 3/4" G 1" G 1-1/4" G 1-1/2" G 2" DN 15 20 25 32 40 50 order number AC-15TF AC-20TF AC-25TF AC-32TF AC-40TF AC-50TF connection set description internal thread consisting of 1 union nut, 1 tailpiece, and 1 gasket dimensions of connection sets a G 1-1/8" G 1-1/4" G 1-1/2" G 2" G 2-1/4" G 2-3/4" c G 1/2" G 3/4" G 1" G 1-1/4" G 1-1/2" G 2" order number AC-15TF AC-20TF AC-25TF AC-32TF AC-40TF AC-50TF 3 EN0B-0408GE51 R0407 V5013E DIMENSIONS valve size DN15 DN20 DN25 DN32 DN40 DN50 Table 4. Dimensions (in mm) A 80 90 110 120 130 150 B 40 40 40 40 40 40 C 55 55 55 55 60 65 Y1 stem up Y2 stroke Y2 Y1, 2 Y1 107 151 For actuator dimensions, please refer to: ML6420A3072 . . . . . . . . . . . . . . . . . . . . EN0B-0411GE51 ML6420A / ML6425A, B. . . . . . . EN0B-0351GE51 ML7420 / ML7425 . . . . . . . . . . . . . . . [. . . ] Dimensions Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Ecublens, Route du Bois 37, Switzerland by its Authorized Representative: Automation and Control Solutions Honeywell GmbH Böblinger Straße 17 D-71101 Schönaich Phone: (49) 7031 63701 Fax: (49) 7031 637493 http://europe. hbc. honeywell. com Subject to change without notice. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL V5013E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL V5013E will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag