User manual HONEYWELL V5016A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL V5016A. We hope that this HONEYWELL V5016A user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL V5016A.


Mode d'emploi HONEYWELL V5016A
Download
Manual abstract: user guide HONEYWELL V5016A

Detailed instructions for use are in the User's Guide.

[. . . ] FLANGED LINEAR VALVE PN16 SPECIFICATION DATA V5016A FEATURES · · · · · · · · Pressure-balanced plug Nodular iron body with flanged end connections Low seat leakage rate Metal-to-metal seating for long life span Self-adjusting packing Accurate positioning to ensure state-of-the-art temperature control Easy mounting of direct-coupled electric and pneumatic actuators Approved according to DIN EN 14597 in DN15. . . 80 in combination with ML6425/ML7425 SPECIFICATIONS Action Nominal pressure rating Flow characteristic Rangeability Leakage rate Stroke Valve body End connections Material Dimensions Trim Seat Stem Plug Packing Medium temperature and pressure Max. [. . . ] district heating) and can be operated by linear actuators ML6420/ML6425, ML7420/ML7425, or M6421/M7421 or by pneumatic actuators MP953. Copyright © 2009 Honeywell Inc. · All Rights Reserved EN0B-0440GE51 R0709 V5016A FLANGED LINEAR VALVE PN16 SIZES AND FLOW CAPACITIES Order Number V5016A1010 V5016A1028 V5016A1036 V5016A1044 V5016A1051 V5016A1069 V5016A1077 V5016A1085 V5016A1093 V5016A1101 V5016A1119 V5016A1127 V5016A1135 V5016A1143 V5016A1150 V5016A1168 Valve Size DN15 DN15 DN15 DN15 DN15 DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 kVS 0. 40 0. 63 1. 0 1. 6 2. 5 4. 0 6. 3 10. 0 16. 0 25. 0 40. 0 63. 0 100. 0 160. 0 250. 0 360. 0 INSTALLATION · · · · Water should meet VDI 2035 requirements. Do not install valve with stem below the horizontal. Fluid flow must correspond with the arrow direction on the valve body. The installation of a strainer is strongly recommended. REPAIR PACKING KIT Part No. : R43176755004 (DN15. . . 80) R43176755005 (DN100. . . 150) ACTUATORS Electric Actuators 600 N (20 mm) ML6420A ML7420A 600 N (20 mm), spring return ML6425A, B ML7425A, B 1800 N (38 mm) ML6421B ML7421B Pneumatic Actuators actuator model size 5", 8" MP953A 13" MP953B 7" 5", 8" MP953C 13" MP953D 7" stroke 20 mm 38 mm 20 mm 20 mm 38 mm 20 mm acting direct reverse X X X X no positioner yes CLOSE-OFF PRESSURE RATINGS (in kPa) Electric Actuators actuator model stroke ML6420A, ML6425A, B, 20 mm ML7420A, ML7425A, B ML6421B, ML6421B 38 mm force 600 N 1800 N DN15 1600 -DN20 1600 -DN25 1600 -DN32 1600 -DN40 1600 -valve size DN50 DN65 1600 -1600 -DN80 1600 -DN100 -1600 DN125 -1600 DN150 -1600 Pneumatic Actuators actuator spring model range 28. . . 77 kPa MP953A, C (5") (4. . . 11 psi) 28. . . 77 kPa MP953A, C (8") (4. . . 11 psi) 55. . . 90 kPa MP953B, D (7") (8. . . 13 psi) 28. . . 77 kPa MP953A, C (13") (4. . . 11 psi) valve size air pressure 115 kPa 115 kPa 0 kPa 115 kPa DN15 1600 1600 1600 -DN20 1600 1600 1600 -DN25 1600 1600 1600 -DN32 1600 1600 1600 -DN40 1600 1600 1600 -DN50 1200 1600 1600 -DN65 -1600 1600 -DN80 -1600 1600 -DN100 ---1600 DN125 ---1600 DN150 ---1600 EN0B-0440GE51 R0709 2 V5016A FLANGED LINEAR VALVE PN16 DIMENSIONS Valve valve size DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 A 130 150 160 180 200 230 290 310 350 400 480 B 95 99 101 106 150 156 157 133 -190 89 133 -Y1 * Y2 * Y3 * stroke Y2 Y1* Y3 B with stem extension for MP953A, C 8" with stem extension for MP953A, C 13" * = Adjustment dimension. Valve in closed position. *without stem extension for ML6420/25, ML7420/25 M6421, M7421, MP953A, C 5", and MP953B, D 7" A Fig. V5016A with stem extensions (dimensions in mm) Electric Actuators 135x(161) 67. 4 135x(161) 364 (with High-Temperature Kit: 444 mm) 67. 4 322 (with High-Temperature Kit: 402 mm) 178x (178) 64 242 Two knock-outs are provided for cable fitting: 21. 2 (PG13. 5) / 22. 8 (PG16), 18. 9 (PG11) 284 100 0 0 100 100 0 0 100 141 141 Fig. M6421B / M7421B (dimensions in mm) ML6425A, B / ML7425A, B ML6420A / ML7420A Fig. [. . . ] La Pièce 16, Switzerland by its Authorized Representative: Automation and Control Solutions Honeywell GmbH Böblinger Strasse 17 71101 Schönaich Germany Phone: (49) 7031 63701 Fax: (49) 7031 637493 http://ecc. emea. honeywell. com Subject to change without notice. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL V5016A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL V5016A will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag