User manual HONEYWELL V5328A DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL V5328A. We hope that this HONEYWELL V5328A user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL V5328A.


Mode d'emploi HONEYWELL V5328A
Download
Manual abstract: user guide HONEYWELL V5328ADATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] FLANGED LINEAR VALVE PN16 SPECIFICATION DATA V5328A FEATURES · Iron body with flanged end connections · Low seat leakage rate · Metal-to-metal seating for long life span · Self-adjusting packing · Accurate positioning to ensure state-of-the-art temperature control · Easy mounting of direct-coupled electric and pneumatic actuators · Approved according to DIN 32730 SPECIFICATIONS Action Nominal pressure rating Flow characteristic Rangeability Leakage rate Stem down to close PN16 Equal percentage, ngl = 3. 4 50:1 0. 05% of kVS up to DN50 0. 1% of kVS DN65 to DN150 20 mm (DN15 to DN 80) 38 mm (DN100 to DN150) Flanged per ISO 7005-2 Cast iron (GG25) See Fig. [. . . ] All Rights Reserved. EN0B-0291GE51 R0909 V5328A FLANGED LINEAR VALVE PN16 SIZES AND FLOW CAPACITIES order number V5328A1138 V5328A1146 V5328A1153 V5328A1005 V5328A1013 V5328A1021 V5328A1039 V5328A1047 V5328A1054 V5328A1062 V5328A1070 V5328A1088 V5328A1096 V5328A1104 V5328A1112 V5328A1195 V5328A1203 V5328A1211 valve size DN15 DN15 DN15 DN15 DN15 DN15 DN15 DN20 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 kVS 0. 25 0. 40 0. 63 1. 00 1. 60 2. 50 4. 00 4. 00 6. 30 10. 00 16. 00 25. 00 40. 00 63. 00 100. 00 160. 00 250. 00 360. 00 Pneumatic Actuators valve size pneumatic actuator model MP953A MP953B MP953C MP953D size 5", 8" 7" 5", 8" 7" 13" action direct x x x reverse x x yes no yes no positioner DN 15-80 DN MP953A 100-150 MP953C DIMENSIONS (MM) VALVE stroke Y1, 2, 3 INSTALLATION · Water should meet VDI 2035 requirements. · Do not install valve with stem below the horizontal. · Fluid flow must correspond with the arrow direction on the valve body. · The installation of a strainer is strongly recommended. A Fig. V5328A valve size 15 20 25 32 40 50 65 80 100 125 150 adjustment dimension (valve in closed position) Y1 130 150 160 180 200 230 290 310 350 400 480 89 93 112 114 150 157 133 190 89 133 72 Y2 Y3 REPAIR PACKING KIT Part no. : R 43 176 754 - 001 (DN15. . . 32) R 43 176 754 - 002 (DN40. . . 80) R 43 176755 ­ 005 (DN100. . . 150) A B ACTUATORS Electric Actuators force model stroke size 600 N ML6420A ML7420A 600 N spring return ML6425A, B ML7425A, B 20 mm DN15-80 1800 N M6421A M7421A M6421B M7421B 38 mm DN100-150 EN0B-0291GE51 R0909 2 B Y1 Without stem With stem With stem extension for extension for extension for ML6420/25 MP953A, C 8" MP953A, C 13" ML7420/25 M6421, M7421 MP953A, C 5" MP953B, D Y2 Y3 V5328A FLANGED LINEAR VALVE PN16 CLOSE OFF PRESSURE RATINGS in kPa Electric Actuators actuator model ML6420A, ML6425A, B ML7420A, ML7425A, B M6421A, B, M7421A, B valve size force 600 N 1800 N DN15 kVS 0. 25 -1. 0 1600 1600 DN15 kVS 2. 5 -4. 0 1000 1600 DN 20/25 1000 1600 DN 32 600 DN 40 350 DN 50 200 750 DN 65 120 500 DN 80 50 230 DN 100 230 DN 125/150 90 1600 1300 Pneumatic Actuators actuator MP953 actuator spring range 14. . . 48 kPa (2. . . 7 PSI) 27. . . 76 kPa (4. . . 11 PSI) 55. . . 83 kPa (8. . . 12 PSI) 14. . . 48 kPa (2. . . 7 PSI) 27. . . 76 kPa (4. . . 11 PSI) 55. . . 83 kPa (8. . . 12 PSI) 27. . . 76 kPa (4. . . 11 PSI) 55. . . 90 kPa (8. . . 13 PSI) 14. . . 48 kPa (2. . . 7 PSI) 27. . . 76 kPa (4. . . 11 PSI) air pressure in actuator valve size DN15 kVS 0. 25 -1. 60 DN15 kVS 2. 5 -4. 0 DN 20 750 430 240 1600 1500 1200 590 1370 - DN 25 750 430 240 1600 1500 1200 590 1370 - DN 32 430 240 120 1600 900 710 340 810 - DN 40 260 130 60 1000 560 440 200 500 - DN 50 130 70 20 760 360 300 120 350 - DN 65 70 400 190 140 50 160 - DN 80 30 180 80 60 15 70 - DN 100 620 320 DN 125/150 250 120 C 5" A, C 5" C 5" C 8" A, C 8" C 8" D 7" B, D 7" C 13" A, C 13" 1600 1600 1600 115 kPa 1600 1600 1600 1600 0 kPa 1600 115 kPa - 750 430 240 1600 1500 1200 590 1370 - 3 EN0B-0291GE51 R0909 V5328A FLANGED LINEAR VALVE PN16 Pneumatic Actuators E H K E H Electric Actuators 178x (178) 64 70 F F 178x (178) 64 360 NOTE: V5328A valves up to DN50 in combination with the following actuators are approved according to DIN EN 14597. ML6425A3006 ML6425A3014 ML7425A6008 MP953B5003 MP953D5009 Model MP953A 5" MP953C 5" MP953A 8" MP953C 8" MP953A 13" MP953C 13" MP953B MP953D E 130 210 343 180 F 192 237 327 242 G 120 165 255 137 DIN Registration No. ML6421A, M7421A (left) and ML6421B, ML7421B (right), dimensions in mm 142 additional knock-out for cable fitting: 18. 9 (PG11) 135x(161) 1F12392 135x(161) 67. 4 322 (with High-Temperature Kit: 402 mm) 67. 4 204 Fig. MP953A, B, C, D (dimensions in mm) 239 264 MP953A, C MP953B, D additional knock-out for cable fitting: 18. 9 (PG11) 301 326 192 364 (with High-Temperature Kit: 444 mm) 284 H 120 140 200 120 K 242 100 0 0 100 233 100 0 0 100 107 Fig. [. . . ] Printed in Germany EN0B-0291GE51 R0909 141 430 G G [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL V5328A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL V5328A will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag