User manual HONEYWELL V5825B

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL V5825B. We hope that this HONEYWELL V5825B user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL V5825B.


Mode d'emploi HONEYWELL V5825B
Download
Manual abstract: user guide HONEYWELL V5825B

Detailed instructions for use are in the User's Guide.

[. . . ] Small Linear Valve / PN25 DH Compact Valve FEATURES · · · · · · · · · · Pressure-balanced kvs 1. 0. . . 10 m3/hr Normally-closed valve Supplied with manual adjustment cap for start-up Small size Threaded and welding connection sets Bronze body, stainless steel trim Low seat leakage rate Metal-to-metal seating for long life span Easy mounting of direct-coupled electric actuators Approval per DIN EN 14597 V5825B PRODUCT DATA SPECIFICATIONS Action Nominal pressure rating Rangeability Leakage rate: Characteristic Stroke Close-off pressure valve is closed by its spring PN25 50:1 max. 0. 05% of kVS split characteristic / linear - equal percentage 6. 5 mm 0. . . 1600 kPa with 300 N actuator 0. . . 2500 kPa with 400 N actuator external thread per ISO 228/1 red bronze (DIN 1705) stainless steel (W. -No. 1. 4305) EPDM, O-ring water; glycol/water mixture (max. [. . . ] The valve is supplied with a screwed-on valve cap for manual operation and for protection of the system. This allows the system to be filled and set up for the initial heating / cooling during the building construction phase without the use of a controller or actuator. The medium flows through the valve from port A to port B, in the direction of the arrow mark on the valve body. The flow rate is limited by the setting of the valve plug (3), which is positioned either using the manually adjustable valve cap or by an actuator. In order to be able to close precisely against high pressure differences, the valve compensates pressure differences by means of a cone stem boring (5) connecting to a compensation chamber (6). Some specific actuators automatically retract the stem in the event of a power failure in order to close the valve and stop the flow of medium (refer to section "Actuators" on page 2). 1 4 5 2 3 A 6 B 1 valve insert 2 valve body 3 valve plug 4 return spring 5 cone stem boring 6 compensation chamber INSTALLATION When installing the valve, ensure that the flow direction corresponds with the arrow direction on the valve body (see Installation Instructions MU1B-0224GE51). · The valve must not be mounted with the stem pointing below the horizontal. · The valve should be installed stress-free. External threaded or welding connection sets are available (refer to section "Accessories" on page 5). · The installation of a strainer is strongly recommended; in district heating systems, it is obligatory. · Make sure that water hammers are avoided. · For pressure test, the valve (with actuator) must be open. · The adjustment cap must be removed from the valve only when an actuator is fitted. · The water must not contain more than 50% glycol according to VDI 2035 requirements. Fig. DH Compact Valve V5825B, size DN25 (cross-sectional drawing) MAINTENANCE In case of leakage or heavy soiling of the valve, the complete valve insert (1) can be replaced (see section "Spare Parts" on page 6). 3 EN0B-0403GE51 R0709 V5825B SMALL LINEAR VALVE / PN25 DIMENSIONS Valve V5825B valve normally closed max. 6. 5 11. 5 18 g fmax c a d e Fig. [. . . ] of valve adapter kit AK15-15 AK15-15 AK15-15 AK15-15 AK15-15 AK20-15 AK20-25 AK25-25 n. a. Fig. Valve adapter NOTE: The valve adapter kit contains all of the components required to replace one V5872B valve with the V5825B. Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Rolle, Z. A. La Pièce 16, Switzerland by its Authorized Representative: Automation and Control Solutions Honeywell GmbH Böblinger Strasse 17 71101 Schönaich Germany Phone: (49) 7031 63701 Fax: (49) 7031 637493 http://ecc. emea. honeywell. com Subject to change without notice. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL V5825B

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL V5825B will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag