[. . . ] V5832B/V5833A
Small Linear Valves PN16
PRODUCT DATA
FEATURES
· · · · · · Pressure balanced plug Range of fittings available for different connections Easy to mount, no tools required Flat sealing connections Flat surfaces on body to fit installation tools Standard external threads for Honeywell or field supplied fittings · Adjustment cap for manual operation
V5832B
GENERAL
V5833A
SPECIFICATIONS
Model Operation Nominal pressure rating Capacity index (kVS) Leakage rate Valve body: Material Size Trim: Stem Plug Suitable medium Controlled water temperature: Rangeability Flow characteristic Stroke Dimensions Two-way: V5832B Three-way: V5833A Stem up to close port A to AB PN16 see tables on page 2 0. 05% of kVS Brass DN25 (1"), DN32 (11/4"), DN40 (11/2") Stainless steel Brass Water, with max. [. . . ] This allows the stem set up for filling or initial heating/cooling during the building construction phase without the use of a controller or actuator. The small electric valve actuators provide automatic control during the opening and closing movement of the valve stem.
Three-Way Valves
These valves are preferably used as mixing valves, this means: Port AB: Total flow outlet Port A: Controlled flow inlet Port B: Bypass inlet
TYPICAL OPERATION
All types of valves should be mounted in the return flow. If the p-values exceed 60 kPa, attention should be paid to the development of noise.
AB B
inlet + -
inlet + -
A
AB B
A
Two-Way Valves
Direction of flow always from port A to port B Port B: Outlet Fig. Three-way valve operation
inlet + outlet outlet inlet + -
Fig. Two-way valve operation
EN0B-0408GE51 R0409
2
V5832B/V5833A SMALL LINEAR VALVES PN16
MOUNTING
When installing the valve care must be taken that the flow direction is correct (see section "Typical Operation"). The valve must not be mounted with the stem pointing downward. The adjustment cap must be removed from the valve only when the actuator is fitted. The valve should be installed as stress-free as possible with a tightening torque of 25 to 30 Nm. [. . . ] La Pièce 16, Switzerland by its Authorized Representative:
Automation and Control Solutions Honeywell GmbH Böblinger Strasse 17 71101 Schönaich, Germany Phone: (49) 7031 63701 Fax: (49) 7031 637493 http://ecc. emea. honeywell. com Subject to change without notice. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL V5833A
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.