Manual abstract: user guide HONEYWELL V9406

Detailed instructions for use are in the User's Guide.

[. . . ] With the V9406 Verafix-Cool the flow can either be pre-set according to the diagram on page 6 or, in combination with a measuring instrument, by flow measurement. Features · Flow measuring and pre-setting on one valve at the same time · Six functions in one valve: control, pre-setting, shutoff, measuring, draining and filling · Compact design · Suitable for operating pressures up to 16 bar · Robust, low-noise and flow-efficient valve housing made of corrosion-resistant red bronze Specifications Medium Design The V9406 Verafix-Cool is made up of: · Valve housing PN16, DN15 with 3/4" flat sealing external threads to DIN/ISO 228. Suitable pipe connections see `Accessories' on page 3 · Pre-settable control insert with protection cap · Measuring insert with cap · Union-nuts and sealings Water or water-glycol mixture, quality to VDI2035 8. . . 9. 5 2. . . 130°C (36. . . 266°F) max. [. . . ] Suitable pipe connections see `Accessories' on page 3 · Pre-settable control insert with protection cap · Measuring insert with cap · Union-nuts and sealings Water or water-glycol mixture, quality to VDI2035 8. . . 9. 5 2. . . 130°C (36. . . 266°F) max. 1 bar (14. 5 psi) 2. 5 (2. 91) 0. 02% of kvs-value 50 : 1 3 mm 11. 5 mm M30 x 1. 5 pH-value Operating temperature Operating pressure Close-off pressure with 180N actuator kvs (cv)-value Leakage rate Rangeability Stroke Closing dimension Actuator connection Materials · Valve housing made of red bronze · Valve inserts made of brass with EPDM O-rings and soft seals · Protection cap made of white plastic · Cap made of brass with PTFE sealing ring · Union-nuts made of brass with EPDM sealing rings Suitable Actuators · Honeywell M6410/M7410 with 180N Honeywell · All rights reserved EN0H-0198GE25 R0406 V9406 VERAFIX-COOL Dimensions Function The V9406 Verafix-Cool is installed in the return of a heat exchanger and controlled by an actuator. The actuator acts onto the spindle of the control insert and in this way regulates the flow through the valve. In a cooling application the actuator closes the valve when the room temperature drops and opens the valve when the room temperature rises. The V9406 Verafix-Cool can also be used for heating applications, in this case operation is the other way round. Dimensions NOTE: Supplied with manual adjustment cap and union-nuts with sealings. Actuator, draining adapter and measuring adapter have to be ordered separately (see Accessories on page 3). Ordering Information Order text V9406 Verafix-Cool control and measuring valve DN 15 Connections G 3/4" A kvs (cv)-value 2, 5 (2, 91) OS-No. V9406DX015 EN0H-0198GE25 R0406 2 Honeywell · All rights reserved V9406 VERAFIX-COOL Installation Examples Fig. Regulation of chilled ceilings: a V9406 Verafix-Cool is fitted in the return pipe of chilled ceiling systems. Fig. Due to the high kvs-value, a single V9406 VerafixCool can be used to control several ceiling elements connected in parallel. Accessories Draining adapter VA3300A001 Connections Externally threaded brass tailpiece, flat sealing R1/2" (to DIN2999) NPT1/2" (NPT thread!) Brass soldering tailpiece, flat sealing VA5500A015 VA5501A015 Special Verafix-key VA8300A001 15 mm 16 mm Steel welding tailpiece, flat sealing 1/2" VA5930A015 VA5930A016 VA5540A015 Accessories for Measuring Measuring adapter VA3301A001 Internally threaded nickel-plated brass tailpiece, flat sealing Rp1/2" VA5920A015 BasicMES handheld measuring computer VM241A1002 Honeywell · All rights reserved 3 EN0H-0198GE25 R0406 V9406 VERAFIX-COOL Shutoff 9 87 32 1 54 Pre-setting kv-value cv-value 1 6 5 0, 63 0, 73 8 1, 00 1, 16 13 1, 60 1, 86 16 2, 00 2, 33 20 = open 2, 50 2, 91 Stop = closed Use protection cap for longer-term shutoff Draining and Filling 1 19 mm 2 4 mm 3 10 mm VA8300A001 4 VA3300A001 5 G 3/4" A 6 10 mm Flow of water during draining EN0H-0198GE25 R0406 4 Honeywell · All rights reserved V9406 VERAFIX-COOL Pre-setting 1 2 32 1 9 87 1x 2x 32 9 1 9 32 20 = open Factory setting = 20 Turn back to required pre-setting Measuring and Pre-setting 1 19 mm 2 VA3301A001 3 + ­ 4 9 87 32 Honeywell · All rights reserved 5 1 EN0H-0198GE25 R0406 1 87 87 6 54 = 10 = 20 6 54 6 54 6 54 V9406 VERAFIX-COOL Flow Diagram Pre-setting kv-value cv-value 5 0, 63 0, 73 8 1, 00 1, 16 13 1, 60 1, 86 16 2, 00 2, 33 20 = open kvs = 2, 50 2, 91 NOTE: Flow data is only valid for water with a temperature of 5. . . 30°C (41. . . 86°F). [. . . ] Regulation of chilled ceilings: a V9406 Verafix-Cool is fitted in the return pipe of chilled ceiling systems. Fig. Due to the high kvs-value, a single V9406 VerafixCool can be used to control several ceiling elements connected in parallel. Accessories Draining adapter VA3300A001 Connections Externally threaded brass tailpiece, flat sealing R1/2" (to DIN2999) NPT1/2" (NPT thread!) Brass soldering tailpiece, flat sealing VA5500A015 VA5501A015 Special Verafix-key VA8300A001 15 mm 16 mm Steel welding tailpiece, flat sealing 1/2" VA5930A015 VA5930A016 VA5540A015 Accessories for Measuring Measuring adapter VA3301A001 Internally threaded nickel-plated brass tailpiece, flat sealing Rp1/2" VA5920A015 BasicMES handheld measuring computer VM241A1002 Honeywell · All rights reserved 3 EN0H-0198GE25 R0406 V9406 VERAFIX-COOL Shutoff 9 87 32 1 54 Pre-setting kv-value cv-value 1 6 5 0, 63 0, 73 8 1, 00 1, 16 13 1, 60 1, 86 16 2, 00 2, 33 20 = open 2, 50 2, 91 Stop = closed Use protection cap for longer-term shutoff Draining and Filling 1 19 mm 2 4 mm 3 10 mm VA8300A001 4 VA3300A001 5 G 3/4" A 6 10 mm Flow of water during draining EN0H-0198GE25 R0406 4 Honeywell · All rights reserved V9406 VERAFIX-COOL Pre-setting 1 2 32 1 9 87 1x 2x 32 9 1 9 32 20 = open Factory setting = 20 Turn back to required pre-setting Measuring and Pre-setting 1 19 mm 2 VA3301A001 3 + ­ 4 9 87 32 Honeywell · All rights reserved 5 1 EN0H-0198GE25 R0406 1 87 87 6 54 = 10 = 20 6 54 6 54 6 54 V9406 VERAFIX-COOL Flow Diagram Pre-setting kv-value cv-value 5 0, 63 0, 73 8 1, 00 1, 16 13 1, 60 1, 86 16 2, 00 2, 33 20 = open kvs = 2, 50 2, 91 NOTE: Flow data is only valid for water with a temperature of 5. . . 30°C (41. . . 86°F). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL V9406

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL V9406 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag