Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL W7751H. We hope that this HONEYWELL W7751H user guide will be useful to you.
Lastmanuals help download the user guide HONEYWELL W7751H.
Detailed instructions for use are in the User's Guide.
[. . . ] ([FHO :%')+ 9$9, , &RQWUROOHUV
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Description of Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Control Application. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Control Provided . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] The EEPROM device has a maximum 10, 000 allowable number of writes. This means that these parameters should not be written to frequently by another controller that is calculating values every few seconds and sending these values to an Excel 10 VAV Controller.
IMPORTANT Excel 10 VAV Controllers are not capable of controlling both a staged type reheat device and a modulating reheat device in the same VAV box. The W7751H Smart VAV Actuator is a physically smaller controller in the Excel 10 family product line. It has a factory-mounted ML6161B1000 Actuator and was designed for basic VAV box control applications. It has all of the control and communications functionality of the W7751B, D, F Controllers with the exception of the following. Physical digital inputs for window open/closed or an occupancy sensor or physical outputs for stage three reheat. It also does not contain a network access communications jack or a selftest input.
Table 11. Default User Address MaxFlowSpt MinFlowSpt MinFlowHtgSpt MinFlowSbySpt CoolOccSpt* CoolStbySpt* Description Air flow rate not to be exceeded during normal Occupied operation. Minimum air flow rate to be maintained during normal operation. Air flow rate to be maintained during reheat operation (Pressure Independent ReheatFlowSpt). Air flow rate to be maintained during STANDBY operation. Allowable Values 0 to 10, 000 CFM (0 to 16, 990) m3h 0 to 10, 000 CFM (0 to 16, 990) m3h 0 to 10, 000 CFM (0 to 16, 990) m3h 0 to 10, 000 CFM (0 to 16, 990) m3h Default Value 1, 000 CFM (1, 700) m3h 0 0 0 73. 4°F (23°C) 77°F (25°C) 82. 4°F (28°C) 70°F (21°C) 66°F (19°C)
Space Temperature Setpoint to be maintained during OCC time while 50 to 95°F in COOL mode operation. (10 to 35°C) Space Temperature Setpoint to be maintained during STANDBY while 50 to 95°F in COOL mode operation. This value is also used to provide an upper (10 to 35°C) limit on the user adjustable remote setpoint pot (wall module). Space Temperature Setpoint to be maintained during UNOCC while in 50 to 95°F COOL mode operation. (10 to 35°C) Space Temperature Setpoint to be maintained during OCC time while 50 to 95°F in HEAT/REHEAT mode operation. (10 to 35°C) Space Temperature Setpoint to be maintained during STANDBY while 50 to 95°F in HEAT/REHEAT mode operation. This value is also used to provide (10 to 35°C) a lower limit on the user adjustable remote setpoint pot (wall module) minus Deadband (E-Vision Application selection). Space Temperature Setpoint to be maintained during UNOCC while in 50 to 95°F HEAT/REHEAT mode operation. (10 to 35°C) Number of minutes to stay in BYPASS mode after the Bypass digital input is pressed. 0 to 1080 min
CoolUnoccSpt* HeatOccSpt* HeatStbySpt*
HeatUnoccSpt* BypassTime
61°F (16°C) 180 min
(continued)
74-29491
68
EXCEL 10 W7751B, D, F, H VAVII CONTROLLERS
Table 11. Default User Address DlcBumpTemp Description Amount (in degrees) to adjust the Cooling Setpoint upward, or the Heating Setpoint downward, when a high electrical demand condition exists. [. . . ] First entry must be 0. 00 differential pressure and 0 velocity. Maximum differential pressure entry must not be greater than 2. 00 Inw (0. 5 kPa). Maximum flow velocity entry must not be greater than 3500 FPM (1778 L/sec). All entries must be sequential and increasing in values. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL W7751H
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL W7751H will begin.