User manual HONEYWELL WIREFREE 2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL WIREFREE 2. We hope that this HONEYWELL WIREFREE 2 user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL WIREFREE 2.


Mode d'emploi HONEYWELL WIREFREE 2
Download
Manual abstract: user guide HONEYWELL WIREFREE 2

Detailed instructions for use are in the User's Guide.

[. . . ] The HR80s control the temperature in each room individually and they send the current heat demand to the HC60NG boiler controller. CM67Z controller can also be used to control a zone valve (only in zone 1) The concept of individual room control at each radiator allows the system to be applied in any installation, no re-plumbing required. The CM67Z uses reliable RF communication technology in the 868MHz band. [. . . ] The measured values is used by all HR80 is zone1. When built-in sensor is disabled will also display the measured temperature. The selected value is transferred via RF communication to HC60NG and is used as the key boiler control parameter To ensure synchronous operation of the boiler and zone valves (controlled by HC60NG) in the system one of the CM67Z has to be configured as the system timing master sending the sync signal co-ordinating on/off cycling of all HC60NGs. The CM67 allows you to set the fail-safe mode of operation of the heating system if radio communication is lost. By default HC60 boiler controller relay will be switched OFF in case of communication loss. Alternatively you may choose to cycle the boiler at 2 min ON and 8min OFF. Useful when the building is not occupied for long periods of time and there is a high risk of frost damage. Allows sending a special message to control HC60NG operating as zone valve controller. In this way flow in the whole zone can be controlled with just one valve. This type of control can only be used for zone 1 According to factory default operation HR80 controller will close the valve when open window is detected. This parameter allows configuring the HR80 to perform or ignore this function. Z 0* - disabled 1 ­ enabled 6 cph (10 min)* (other values: 3, 9) 0* ­ normal operation 1 ­ system timing master 0* ­ relay OFF 1 ­ relay cycles Zone valve control enable 17:CE Open window detection function 18:Ho 0* - disabled 1 ­ enabled 3* - enabled 0 - disabled in zone 1 &2 1 - enabled in zone 1 2 ­ enabled in zone 2 HR80 local override 19:HL According to factory default local override of HR80 setpoint is enabled. This parameter allows disabling this function if required. 3* - enabled 0 - disabled in zone 1 &2 1 - enabled in zone 1 2 ­ enabled in zone 2 * - factory default values 3 EN0R 8534R0 03/03 CM67Z ZONE CONTROLLER APPLICATIONS OVERVIEW The CM67 was designed to provide control of residential zoning system in variety of installation. It can be used for system with vertical heat distribution as well as for the ones with manifolds. Re-plumbing f the installation is not required. [. . . ] Boiler Controller (HC60NG) - receives the signals from all HR80s in the system, calculates boiler on time to satisfy the heat demand in the whole house DIMENSIONS Room unit T6667Z ORDERING SPECIFICATION Description CM67 Zone Controller Boiler Controller (HC60NG) RF Radiator Controller Z Model Y6667Z1007 Logo Honeywell Literature EN Spec Sheet ENOR8534 R6660D1009 HR80 Honeywell Honeywell EN, GE EN. GE, FR, NL, IT, SP ENOR8535 ENOH0445 GE51R0303 3 EN0R 8534R0 03/03 CM67RF NG CHRONOTHERM INSTALLATION The CM67Z is a radio frequency device and for the best performance should be installed in an open space. Leave at least 30cm distance from any metal objects including wall boxes and at least 1 metre from any other electrical equipment e. g. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL WIREFREE 2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL WIREFREE 2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag