Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HOTPOINT-ARISTON GLTI. We hope that this HOTPOINT-ARISTON GLTI user guide will be useful to you.
Lastmanuals help download the user guide HOTPOINT-ARISTON GLTI.
Detailed instructions for use are in the User's Guide.
[. . . ] mini-tank electric water heaters chauffe-eau électriques à miniréservoir calentadores de agua eléctricos de minitanque
Meets ASHRAE 90. 1 standard
INSTALLATION MANUAL FOR DIRECTIVES D'INSTALLATION POUR INSTRUCCIONES DE SEGURIDAD IMPORTANTES
GL2. 5Ti GL4Ti GL8Ti
CONTROLLED ENERGY CORPORATION 340 Mad River Park Waitsfield, Vermont 05673 800-798-8161 · www. Protankless. com
IMPORTANT SAFETY INSTRUCTIONS
WARNING
When using electrical appliances, safety precautions to reduce the risk of fire, electric shock or injury to persons should be followed, including: 1. READ ALL INSTRUCTIONS BEFORE USING THIS WATER HEATER. Connect only to properly grounded outlet. See "GROUNDING INSTRUCTIONS" found on "INSTALLATION INSTRUCTIONS". [. . . ] During the heating cycle of the water heater, the water expands causing pressure inside the water heater to increase. The temperature and pressure relief valve may discharge hot water under these conditions which results in a loss of energy and a build-up of lime on the relief valve seat. To prevent this from happening, there are two recommendations: 1. Install a diaphragm-type expansion tank that is suitable for potable water on the cold water supply line. The expansion tank must have a minimum capacity of 1. 5 U. S. gallons for every 50 gallons of stored water. Install a 125 PSI pressure relief valve in the cold water supply line. Make sure the discharge of this valve is directed to an open drain and protected from freezing. Contact the local water supplier or plumbing inspector for information on how to control this situation. Do not plug the temperature and pressure relief valve.
Closed system thermal expansion (for all models)
Instructions for use
Starting and testing
Before connecting the power, fill the tank and system with water and check for leaks. To be certain that all air is out of the water system, open the hot water faucets on your fixtures until constant water flows from them, otherwise damage to the element may occur. To start the heating cycle: A) first make sure tank is full. Otherwise the heating element may be damaged. B) the red light will come on and remain on until that temperature has been reached, at which point the light will go off, but will automatically come back on when the water temperature drops below the setting chosen. After installation check the water temperature. If adjustment is necessary, remove front cover to adjust thermostat (D Fig. 4 -clockwise to increase the temperature and counter clockwise to decrease it). 3/1) with a small flat-head screwdriver. Remove the Phillips screw revealed beneath the round cover plate.
Temperature Setting
6
3.
The cover (C Fig. 3/1) can now be removed by pulling out its left-hand edge. When reassembling, work in the opposite way being careful to insert the tongue of the cover into the slot.
FIG. 4
B
D
Maintenance instructions
Note: Do not attempt to repair this water heater yourself. [. . . ] Check water fittings and T & P fitting on top of tank. Remove front cover and inspect heating element gasket. 9
Light not on
Brown water Odor in water Water is too hot Water not hot enough Leaking
DESCRIPTION REF.
GL 2. 5Ti GL 4Ti GL 8Ti
A B C
PART 1 2 2 3 4 5 5 6 7 8 9 10 11 11 12 13 14 15
CODE 100XL 570241 574305 994147 994140 994103 994104
DESCRIPTION VALVE (T&P 3/4") ANODE (MAGNESIUM) ANODE (MAGNESIUM) GASKET WITH 4 BOLTS LOCK NUT M6 HEATING ELEMENT (1500/120) HEATING ELEMENT (1500/120) PLASTIC COVER RETAINING SCREW NAME BADGE (PLASTIC) COVER SWITCH COVER THERMOSTAT WIRING 994062 THERMOSTAT 994102 THERMOSTAT CABLE CLAMP SUPPLY CABLE 570341 HEATER WALL HANGING BRACKET gl6plug 3/4" BRASS PLUG (GL6 ONLY)
REF. ABC C AB ABC ABC AB C
ARISTON INTERIOR COMPONENTS DIAGRAM GL 2. 5Ti, 4Ti, 8Ti
AB C AB ABC C
10
ARISTON GLTi · LIMITED 8 YEARS WARRANTY
COVERAGE ARISTON, THROUGH ITS U. S. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HOTPOINT-ARISTON GLTI
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HOTPOINT-ARISTON GLTI will begin.