User manual HOTPOINT CISTD 640 ES

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HOTPOINT CISTD 640 ES. We hope that this HOTPOINT CISTD 640 ES user guide will be useful to you.

Lastmanuals help download the user guide HOTPOINT CISTD 640 ES.


Mode d'emploi HOTPOINT CISTD 640 ES
Download
Manual abstract: user guide HOTPOINT CISTD 640 ES

Detailed instructions for use are in the User's Guide.

[. . . ] Congratualtions on choosing an Ariston appliance, which you will find is dependable and easy to use. We recommend that you read this manual for best performance and to extend the life of your appliance. Thank you. Close-up View A F B C D A. Gas Burners Support Grid for Cookware Control Knobs for Gas Burners Ignitor for Gas Burners (only on certain models) Safety Device (only on certain models) - Activates if the flame accidentally goes out (spills, drafts, etc. ), interrupting the delivery of gas to the burner. How To Use Your Appliance The position of the corresponding gas burner is indicated on each control knob. [. . . ] d) Liquidified petroleum gases are heavier than air and, as a result, settle downwards. Rooms in which LPG tanks are installed must be fitted with ventilation openings to the outside in order to allow the gas to escape in the event of a leak. Therefore, LPG tanks, whether empty or partially full, must not be installed or stored in rooms or spaces below ground level (cellars, ect. ). It is also a good idea to keep only the tank currently being used in the room, making sure that it is not near sources of heat (ovens, fireplaces, stoves, etc. ) that could raise the internal temperature of the tank above 50C. Installation of Built-in Cooktops The appliance can be installed next to furniture units which are no taller than the top of the cooker hob. The wall in direct contact with the back panel of the cooker must be made of non-flammable material. During operation the back panel of the cooker could reach a temperature of 50C above room temperature. For proper installation of the cooker, the following precautions must be taken: a) If the cabinet(s) located next to the cooktop are higher than the cooktop itself, the cabinet(s) must be installed at least 600 mm from the edge cooktop; b) Hoods must be installed in accordance with the instructions contained in the installation manual for the hoods themselves, and no less than 650 mm from the 5 In a chimney stack or branched flue. (exclusively for cooking appliances) Directly to the Outside b) The room must also allow for the influx of the air needed for proper combustion. The flow of air for combustion purposes must not be less than 2 m/h per kW of installed capacity. The supply of said air can be effected by means of direct influx from the outside through a duct with a inner cross section of at least 100 cm which must not be able to be accidentally blocked. Those appliances which are not fitted with a safety device to prevent the flame from accidentally going out must have a ventilation opening twice the size otherwise required, i. e. If not, follow the instructions indicated in the section entitled, ?Adapting the Cooktop for Different Types of Gas?. If the cooktop is to be connected to tanks containing liquid gas, use pressure regulators that comply with current safety standards. Important: To insure that the appliance operates safety, the gas is regulated correctly and your appliance lasts over time, make sure that gas pressure levels comply with the indications given in Table 1, ?Nozzle and Burner Specifications?. Gas Connection to Non-flexible Pipe (copper or steel) Connection to the gas source must be done in such a way as to not create any stress points at any part of the appliance. The appliance is fitted with an adjustable, "L" shaped connector and a gasket for the attachment to the gas supply. Should this connector have to be turned, the gasket must be replaced (supplied with the appliance). The gas feed connector to the appliance is a threaded, male 1/2" connector for round gas pipe. Gas Connection to Flexible Steel Pipe The gas feed connector to the appliance is a threaded, male 1/2" connector for round gas pipe. Only use pipes, tubes and gaskets that comply with current safety codes. The maximum length of the flexible pipes must not exceed 2000 mm. [. . . ] , , Merloni Elettrodomestici, : - . . - : 3. ; (, ); ; , / ; ; . , . , : - ; - (, , . . ); - ; - ( ). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HOTPOINT CISTD 640 ES

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HOTPOINT CISTD 640 ES will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag