User manual HOTPOINT PH 741 RQO GH AUS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HOTPOINT PH 741 RQO GH AUS. We hope that this HOTPOINT PH 741 RQO GH AUS user guide will be useful to you.

Lastmanuals help download the user guide HOTPOINT PH 741 RQO GH AUS.


Mode d'emploi HOTPOINT PH 741 RQO GH AUS
Download
Manual abstract: user guide HOTPOINT PH 741 RQO GH AUS

Detailed instructions for use are in the User's Guide.

[. . . ] Operating Instructions HOB Contents GB English, 1 GB Installation, 2-5 Positioning Electrical connection Gas connection Data plate Burner and nozzle specifications Description of the appliance, 6 Overall view Start-up and use, 7-8 Practical advice on using the burners Practical advice on using the the Ceramic Glass Module Precautions and tips, 9 PH 750 RT GH AUS PH 741 RQO GH AUS PH 723 RQO GH AUS General safety Disposal Maintenance and care, 10 Switching the appliance off Cleaning the appliance Gas tap maintenance Troubleshooting, 11 Installation GB !Before operating your new appliance please read this instruction booklet carefully. It contains important information for safe use, installation and care of the appliance. Please keep these operating instructions for future reference. [. . . ] Replace the nozzle with models suited to the new type of gas (see table 1). replace all the components by repeating the steps in reverse order. • Adjusting the burners’ primary air : Does not require adjusting. Remove the knob and adjust the adjustment screw, which is positioned in or next to the tap pin, until the flame is small but steady. 3. Having adjusted the flame to the required low setting, while the burner is alight, quickly change the position of the knob from minimum to maximum and vice versa several times, checking that the flame does not go out. Some appliances have a safety device (thermocouple) fitted. If the device fails to work when the burners are set to the low flame setting, increase this low flame setting using the adjusting screw. Once the adjustment has been made, replace the seals on the by-passes using sealing wax or a similar substance. If the appliance is connected to liquid gas, the regulation screw must be fastened as tightly as possible. Once this procedure is finished, replace the old rating sticker with one indicating the new type of gas used. Stickers are available from any of our Service Centres. Should the gas pressure used be different (or vary slightly) from the recommended pressure, a suitable pressure regulator must be fitted to the inlet pipe (in order to comply with current national regulations). DATA PLATE Electrical connections see data plate This appliance conforms to the following European Economic Community directives: -73/23/EEC dated 19/02/73 (Low Voltage) and subsequent amendments - 89/336/EEC dated 03/05/89 (Electromagnetic Compatibility) and subsequent amendments - 93/68/EEC dated 22/07/93 and subsequent amendments. - 90/336/EEC dated 29/06/90 (Gas) and subsequent amendments. - 2002/96/EC 4 Burner and nozzle specifications Table 1 Burner Diameter (mm) Propane Nominal Thermal Power (MJ/h)* Semi Rapid (S) Auxiliary (A) Triple Crown (TC) Double flame (DCDR internal) Double flame (DCDR external) 2 nozzle Supply pressures 75 55 130 30 5, 5 3, 5 13, 5 3, 5 Nozzle 1/100 (mm) 64 50 100 50 Natural Gas Nominal Thermal Power (MJ/h)* 6, 0 3, 3 15, 0 3, 3 Nozzle 1/100 (mm) 110 80 175 80 GB 130 Nominal (kPa) Minimum (kPa) Maximum (kPa) 15, 0 2, 75 2, 00 3, 50 75 15, 5 1, 00 0, 75 1, 20 125 * At 15°C and 101, 3 kPa dry gas Propane = 95, 8 MJ/m³ Natural gas = 37, 8 MJ/m³ Total Thermal Power (MJ/h) Propane PH 750 RT GH AUS PH 741 RQO GH AUS PH 723 RQO GH AUS 41, 0 27, 5 18, 5 Natural Gas 43, 1 28, 1 18, 8 S DC A PH 750 RT GH AUS S TC DC A PH 741 RQO GH AUS DC PH 723 RQO GH AUS !In the case of the smaller pots and pans we recommend the use of only the internal burner. There is a separate control knob for each of the “separate double flame” burners. The knob marked by the symbol operates the external burner; The knob marked by the symbol operates the internal burner. To turn on one of the rings, press the relative knob in all the way and turn it anti-clockwise to the high setting . The burner is fitted with an electronic igniter that automatically starts when the knob is pressed in. Since the burner is equipped with a safety device, after lighting the burner keep the knob pressed in for about 2-3 seconds to allow the device which keeps the flame lit automatically to heat up. The selected burner can be regulated using the corresponding knob, as follows: • Off Maximum Minimum To switch off the burner, turn the knob in a clockwise direction until it stops (when reaches the “•” position). Ceramic Glass Module* This cooktop is fitted with dual-ring radiant heating elements located beneath the glass. It is possible to turn on only the circular part of the elemement (identified by the letter "A") or the cooking surface can be enlarged by turning on both "A" and "B". [. . . ] First, remove all food buildup or grease with a cleaning scraper, e. g. Clean the cooking surface when it is still warm with a suitable cleaning product (such as the one in the Solutions product line available from any AfterSales Service Centre) and paper towels. Aluminum foil, plastic items, objects made of synthetic material, sugar or foods with a high sugar content that have melted onto the surface must be removed immediatley with a scraper while the cooking surface is still hot. Special cleaning products for ceramic glass surfaces form a transparent protective layer which fights diry buildup. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HOTPOINT PH 741 RQO GH AUS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HOTPOINT PH 741 RQO GH AUS will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag