Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HP COMPAQ PROLIANT 1500 SERVER. We hope that this HP COMPAQ PROLIANT 1500 SERVER user guide will be useful to you.
Lastmanuals help download the user guide HP COMPAQ PROLIANT 1500 SERVER.
You may also download the following manuals related to this product:
HP compaq proliant 1500 server annexe 1 (230 ko)
HP COMPAQ PROLIANT 1500 SERVER COMPAQ SURVEY UTILITY (802 ko)
HP COMPAQ PROLIANT 1500 SERVER NETWARE 5: AT YOUR COMMAND (73 ko)
HP COMPAQ PROLIANT 1500 SERVER DISK DRIVE TECHNOLOGY OVERVIEW (174 ko)
HP COMPAQ PROLIANT 1500 SERVER DEPLOYING PCI HOT PLUG ON COMPAQ (150 ko)
HP COMPAQ PROLIANT 1500 SERVER COMPAQ TIPS AND TRICKS FOR NETWARE 5 (135 ko)
HP COMPAQ PROLIANT 1500 SERVER PROLIANT SERVER TROUBLESHOOTING GUIDE (2147 ko)
HP COMPAQ PROLIANT 1500 SERVER INTRANETWARE SYMMETRIC MULTIPROCESSING (82 ko)
HP COMPAQ PROLIANT 1500 SERVER SAP R/3 ON THE COMPAQ PROLIANT PLATFORM (162 ko)
HP COMPAQ PROLIANT 1500 SERVER COMPAQ LEADERSHIP IN SERVER INNOVATIONS (104 ko)
HP COMPAQ PROLIANT 1500 SERVER I/O PERFORMANCE TUNING OF COMPAQ SERVERS (246 ko)
HP COMPAQ PROLIANT 1500 SERVER LAN DRIVER STATISTICS FOR NOVELL DRIVERS (94 ko)
HP COMPAQ PROLIANT 1500 SERVER SMART-2DH ARRAY CONTROLLER REFERENCE GUIDE (3296 ko)
HP COMPAQ PROLIANT 1500 SERVER BACKUP OF WINDOWS NT SAP R/3 SYSTEMS WITH ARCSERVE (387 ko)
HP COMPAQ PROLIANT 1500 SERVER ARCHITECTING AND DEPLOYING HIGH-AVAILABILITY SOLUTIONS (76 ko)
HP COMPAQ PROLIANT 1500 SERVER COMPAQ BACKUP AND RECOVERY FOR MICROSOFT SQL SERVER 6.X (578 ko)
HP COMPAQ PROLIANT 1500 SERVER PCI BUS NUMBERING IN A MICROSOFT WINDOWS NT ENVIRONMENT (560 ko)
HP COMPAQ PROLIANT 1500 SERVER DDS-3 ENHANCING DAT RELIABILITY, CAPACITY, AND PERFORMANCE (161 ko)
HP COMPAQ PROLIANT 1500 SERVER MIGRATING TO MICROSOFT WINDOWS NT SERVER 4.0 ON COMPAQ SERVERS (138 ko)
HP COMPAQ PROLIANT 1500 SERVER EURO CURRENCY SYMBOL ON COMPAQ TOWER AND RACK SERVER KEYBOARDS (37 ko)
HP COMPAQ PROLIANT 1500 SERVER SERVERNET - A HIGH BANDWITH, LOW LATENCY CLUSTER INTERCONNECTION (30 ko)
HP COMPAQ PROLIANT 1500 SERVER PERFORMANCE OF MICROSOFT EXCHANGE SERVER 4.0 ON COMPAQ PROLIANT SERVERS (122 ko)
HP COMPAQ PROLIANT 1500 SERVER COMPAQ RECOVERY SERVER SOLUTIONS FOR SAP R/3 ON VARIOUS DATABASE PLATFORMS (369 ko)
HP COMPAQ PROLIANT 1500 SERVER CONFIGURATION AND TUNING OF SYBASE SYSTEM 11 FOR NETWARE ON COMPAQ SERVERS (142 ko)
HP COMPAQ PROLIANT 1500 SERVER ORDER AND CONFIGURATION GUIDE FOR COMPAQ PROLIANT CLUSTER SERIES S MODEL 100 (265 ko)
HP COMPAQ PROLIANT 1500 SERVER PCI HOT PLUG EXPAND FEATURE ON COMPAQ SERVERS IN NOVELL NETWARE ENVIRONMENTS (135 ko)
HP COMPAQ PROLIANT 1500 SERVER PCI HOT PLUG EXPAND AND FIBRE CHANNEL MIGRATION IN NOVELL NETWARE ENVIRONMENTS (779 ko)
HP COMPAQ PROLIANT 1500 SERVER VIRTUAL INTERFACE (VI) ARCHITECTURE - THE NEW OPEN STANDARD FOR DISTRIBUTED MESS (30 ko)
HP COMPAQ PROLIANT 1500 SERVER INSTALLATION AND CONFIGURATION GUIDE FOR LINUX AND APACHE WEB SERVER ON COMPAQ P (203 ko)
HP COMPAQ PROLIANT 1500 SERVER CONFIGURATION AND TUNING OF SYBASE SQL SERVER 11 FOR SCO UNIXWARE 2.1 ON COMPAQ (150 ko)
Manual abstract: user guide HP COMPAQ PROLIANT 1500 SERVER
Detailed instructions for use are in the User's Guide.
[. . . ] ONLINE STORAGE
CONTROLLER RECOVERY OPTION
USER GUIDE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Online Storage Controller Recovery Option
User Guide
First Edition (September 1997) Part Number 295586-001 Compaq Computer Corporation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Notice
The information in this publication is subject to change without notice. COMPAQ COMPUTER CORPORATION SHALL NOT BE LIABLE FOR TECHNICAL OR EDITORIAL ERRORS OR OMISSIONS CONTAINED HEREIN, NOR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE FURNISHING, PERFORMANCE, OR USE OF THIS MATERIAL. THIS INFORMATION IS PROVIDED "AS IS" AND COMPAQ COMPUTER CORPORATION DISCLAIMS ANY WARRANTIES, EXPRESS, IMPLIED OR STATUTORY AND EXPRESSLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE, GOOD TITLE AND AGAINST INFRINGEMENT. This publication contains information protected by copyright. [. . . ] The PCI Hot Plug utility allows you to control the PCI Hot Plug slots on the local system or on a remote system. Although not required for OSCRO, it is useful in the OSCRO environment to prevent downtime.
Continued
No
Compaq System Management Driver
Yes
Compaq Remote Monitor Service
Yes
Compaq PCI Hot Plug
No
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-13
Compaq SSD for Windows NT Components Continued
SSD Component Required for OSCRO Yes Description
Compaq Online Storage Controller Recovery Utility Compaq Fast SCSI-2 Controller Compaq SMART-2 Array Controller Compaq ProLiant Storage System Compaq Netelligent/NetFlex-3 Network Controller(s) Power Down Manager
The Online Storage Controller Recovery Utility manages OSCRO on the local system and on remote systems. Device drivers for Compaq SCSI-2 controllers.
No
Yes
Updated device drivers for Compaq SMART-2 Array Controllers are required to implement OSCRO on the local server. Provides support for Compaq ProLiant Storage Systems only when attached to Compaq SCSI-2 controllers. Device drivers for Compaq network controllers.
No
No
No
Controls the intelligent power down switch in newer ProLiant servers.
Using the Express option directs Setup to detect the devices and software options installed on your system that could be updated with the newer versions on the Compaq SSD for Windows NT. After clicking the Express button, a screen is displayed that shows the options Setup will install. From this screen you can select or deselect any of the options shown.
Installation
Although some of the OSCRO installation steps may already have been completed on your system, all of the steps required for OSCRO implementation are detailed in this section. The basic steps are:
s s
Installing and configuring the hardware Configuring the SMART-2 Array Controllers
Online Storage Controller Recovery Option User Guide
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-14 Planning and Installing the Online Storage Controller
s s
Installing the OSCRO software Making one or more controller pairs
If the controllers you will be using for OSCRO are already installed and configured, go to the next section, "Labeling the Cables. "
Installing the Controllers
The SMART-2 Array Controllers must be installed and configured using the Array Configuration Utility. For additional information, refer to the SMART-2 Array Controller Installation Guide that came with the controllers you will be using for OSCRO. To install SMART-2 Array Controllers: 1. Back up the entire data environment of the server. Shut down Windows NT, and power down the server. Insert the SMART-2 controller(s) necessary for your OSCRO configuration into available PCI slot(s). Boot the system into the System Configuration Utility (version 2. 34A or above) using the System Configuration diskette built from the SmartStart and Support Software CD included in the kit. If you do not have the diskettes required for this step, see Appendix C, "Building Diskettes from the SmartStart and Support Software CD, " for instructions on how to create them. Disable the F1 Boot Prompt using the Advanced Mode of the System Configuration Utility by performing these steps:
t
4. 5.
6.
After passing through the initial screen(s), the Main Menu is displayed. A notice pops up stating that Advanced Mode is enabled. On the Main Menu, select System Configuration.
t
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-15
t t
On the System Configuration Menu, select Configure Hardware. When the automatic configuration is completed, you are given the option to Save changes and exit, or Review and modify hardware settings. Select Review and modify hardware settings. On the Steps in Configuring Your Computer menu, select Step 3: View or edit details. [. . . ] Place the first diskette into the drive. The next screen (see Figure C-2) advises you how to label the diskette. Click the OK button when you are ready to write the first diskette.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C-3
Figure C-2.
Diskette Builder Verification Screen
8. 9.
If the diskette is not blank, you are warned that the operation will destroy all data on the diskette. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HP COMPAQ PROLIANT 1500 SERVER
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HP COMPAQ PROLIANT 1500 SERVER will begin.