If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HP hsg array controller. We hope that this HP hsg array controller user guide will be useful to you.
Lastmanuals help download the user guide HP hsg array controller.
You may also download the following manuals related to this product:
HP hsg array controller annexe 2 (2648 ko)
HP hsg array controller annexe 3 (2181 ko)
HP HSG ARRAY CONTROLLER SMART ARRAY CONTROLLER TECHNOLOGY (745 ko)
Manual abstract: user guide HP hsg array controllerannexe 1
Detailed instructions for use are in the User's Guide.
[. . . ] Compaq StorageWorks UltraSCSI RAID Enclosure (DSBA370 Series) User's Guide
Part Number: EKBA370UG. C02/387403001 September 1998 The DSBA370 series UltraSCSI RAID rack-mountable enclosure is the basic building block of UltraSCSI RAID subsystems. This guide and its related publications comprise the basic documentation set for these subsystems.
Compaq Computer Corporation Houston, Texas
September 1998
While Compaq Computer Corporation believes the information included in this publication is correct as of the date of publication, it is subject to change without notice. Compaq makes no representations that the interconnection of its products in the manner described in this document will not infringe on existing or future patent rights, nor do the descriptions contained in this document imply the granting of licenses to make, use, or sell equipment or software in accordance with the description. [. . . ] 3 -- Used for a second expansion enclosure. Caution To preclude SCSI bus addressing conflicts, Compaq array controllers do not support enclosure address settings of 1, 4, 5, 6, or 7.
Figure 46 Expansion Enclosure Address 2: Shelf and SCSI Bus IDs
1
Figure CALLOUT
5 6
1
2
3
4
1.
SCSI bus
11
2
CXO-4842A-MC
10 9 8
CXO5776B
UltraSCSI RAID Enclosure 49
Power Verification and Addressing
Figure 47 Expansion Enclosure Address 3: Shelf and SCSI Bus IDs
1
Figure CALLOUT
5 6
1
2
3
4
1.
SCSI bus
15
3
CXO-4843A-MC
14 13 12
CXO5777B
Implementing the Standby Power Mode
A major function of the PVA is implementing the standby power mode. This mode removes dc power from all enclosure components, except for the EMU alarm control switch. In standby power mode, the EMU alarm control switch now functions as a dc power switch when pressed. Complete the procedure in Table 44 to place the subsystem into standby power mode. Complete the procedure in Table 45 to restore dc power to each enclosure. Caution Some array controllers bypass the standby power mode functionality from the PVA standby power switch. Refer to the array controller documentation for availability of this feature.
410 UltraSCSI RAID Enclosure
Power Verification and Addressing
Table 44
1. 2.
Turning Off the DC Power Distribution
Clear the cache module and shut down the array controller per the array controller documentation. If there are no expansion enclosures, go to step 3. If there are expansion enclosures, press and hold the PVA standby power switch (CALLOUT 1) on an expansion enclosure until the master EMU initiates a power shut down on all enclosures.
1
CXO6303A
3.
Press and hold the PVA standby power switch (CALLOUT 1 in step 2) on the master enclosure until the EMU initiates a power shut down on the master enclosure.
Note
The EMU alarm control switch (CALLOUT 1 shown below) on each enclosure now functions as the dc power switch.
1 2 3 4
CXO6302A
UltraSCSI RAID Enclosure 411
Power Verification and Addressing
Table 45
1. 2.
Turning On the DC Power Distribution
If there are no expansion enclosures, go to step 3. If there are expansion enclosures, momentarily press the EMU alarm control switch (CALLOUT 1) on each expansion enclosure.
1 2 3 4
CXO6302A
3. 4.
Momentarily press the EMU alarm control switch (CALLOUT 1) on the master enclosure. Verify that the array controller restores the subsystem to an operational state.
Replacing a PVA
Complete the procedures in Table 46 to remove a PVA. Complete the procedures in Table 47 to install a PVA. Table 46
1.
Removing a PVA
Clear the cache module and shut down the controller per array controller documentation.
412 UltraSCSI RAID Enclosure
Power Verification and Addressing
Table 46
2.
Removing a PVA (Continued)
If there are no expansion enclosures, go to step 3. If there are expansion enclosures, press and hold the PVA standby power switch (CALLOUT 1) on an expansion enclosure until the master EMU initiates a power shut down on all enclosures.
1
CXO6303A
3.
Press and hold the PVA standby power switch (CALLOUT 1) on the master enclosure until the master EMU initiates a power shut down on the master enclosure. Turn OFF all the ac input boxes by pressing O on each ac power switch (CALLOUT 1) on any expansion enclosure and then the master enclosure.
4.
1
1
0
2
CXO5488B
UltraSCSI RAID Enclosure 413
Power Verification and Addressing
Table 46
5.
Removing a PVA (Continued)
Note the enclosure address setting (0, 2, or 3) on the PVA SCSI ID switch (CALLOUT 3).
1 2 3
CXO5821A
6.
Pull both extractor latches outward and remove the PVA.
Table 47
1.
Installing a PVA
Verify that the PVA being installed is a model DSBA35XEC.
CXO-5737A
2.
Align the PVA (CALLOUT 2) with the top, right-hand slot and insert it.
2
CXO5754B
414 UltraSCSI RAID Enclosure
Power Verification and Addressing
Table 47
3.
Installing a PVA (Continued)
Pull the PVA extractor latches outward. Push the PVA into the slot until the extractor latches engage the enclosure, then push the extractor latches inward to seat and secure the PVA. Ensure that the PVA SCSI ID switch is set to the valid number for the enclosure: · · · Master enclosure -- 0 First expansion enclosure -- 2 Second expansion enclosure -- 3
4.
5.
If there are no expansion enclosures, go to step 6. If there are expansion enclosures, turn ON all the ac input boxes for each expansion enclosure by pressing I on each ac power switch (CALLOUT 1).
1
1
0
6.
Turn ON all the ac input boxes for the master enclosure by pressing I on each ac power switch (CALLOUT 1).
2
CXO5488B
7.
After the array controller is operational, verify that the subsystem is functioning properly.
UltraSCSI RAID Enclosure 415
5
Single-Ended I/O Module
The single-ended I/O module (see Figure 51) performs two functions: · · Provides termination for both the internal and external SCSI buses Establishes SCSI bus communications between enclosures
Figure 51 Single-Ended I/O Module
CXO5816A
Caution I/O modules provide termination for both the internal and external SCSI buses. [. . . ] terminators The interconnect components that form the ends of the transmission lines in bus segments. A SCSI domain must have at least one segment and therefore at least two terminators. The terminators ensure that inactive SCSI bus signals are in a known state. There are two basic types of terminators--active and passive: · · Single-ended bus segments use active, linear terminators Differential bus segments use passive (linear totem pole) terminators except for special cases where the electrical transmission lines are very short and only one termination or pull-up is required.
terminator connector Any connector physically part of a terminator. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HP hsg array controller
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.