User manual HP PROLIANT DL140 G3 SERVER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HP PROLIANT DL140 G3 SERVER. We hope that this HP PROLIANT DL140 G3 SERVER user guide will be useful to you.

Lastmanuals help download the user guide HP PROLIANT DL140 G3 SERVER.


Mode d'emploi HP PROLIANT DL140 G3 SERVER
Download

You may also download the following manuals related to this product:

   HP proliant dl140 g3 server annexe 1 (2132 ko)
   HP proliant dl140 g3 server annexe 2 (1774 ko)
   HP proliant dl140 g3 server annexe 3 (991 ko)
   HP proliant dl140 g3 server annexe 4 (8307 ko)
   HP proliant dl140 g3 server annexe 5 (1088 ko)
   HP PROLIANT DL140 G3 SERVER DATA CENTER COOLING STRATEGIES (730 ko)
   HP PROLIANT DL140 G3 SERVER DISK DRIVE TECHNOLOGY OVERVIEW (174 ko)
   HP PROLIANT DL140 G3 SERVER POWER BASICS FOR IT PROFESSIONALS (1596 ko)
   HP PROLIANT DL140 G3 SERVER PROLIANT HIGH AVAILABILITY: THE IT IMPERATIVE (288 ko)
   HP PROLIANT DL140 G3 SERVER USB FLOPPY DRIVE KEY INSTALLATION INSTRUCTIONS (533 ko)
   HP PROLIANT DL140 G3 SERVER FULLY-BUFFERED DIMM TECHNOLOGY IN PROLIANT SERVERS (457 ko)
   HP PROLIANT DL140 G3 SERVER ISS TECHNOLOGY UPDATE, VOLUME 7 NUMBER 1 - NEWSLETTER (497 ko)
   HP PROLIANT DL140 G3 SERVER SERVER MIGRATION PACK - UNIVERSAL EDITION SUPPORT MATRIX (946 ko)
   HP PROLIANT DL140 G3 SERVER SERVER MIGRATION PACK - UNIVERSAL EDITION 3.50 RELEASE NOTES (155 ko)
   HP PROLIANT DL140 G3 SERVER IMPLEMENTING MICROSOFT WINDOWS SERVER 2008 ON PROLIANT SERVERS (349 ko)
   HP PROLIANT DL140 G3 SERVER PROLIANT DL140 GENERATION 3 SERVER MAINTENANCE AND SERVICE GUIDE (4465 ko)
   HP PROLIANT DL140 G3 SERVER SYSTEM MEMORY TROUBLESHOOTING BEST PRACTICES FOR PROLIANT SERVERS (740 ko)
   HP PROLIANT DL140 G3 SERVER OPTIMIZING FACILITY OPERATION IN HIGH DENSITY DATA CENTER ENVIRONMENTS (1448 ko)
   HP PROLIANT DL140 G3 SERVER THE INTEL PROCESSOR ROADMAP FOR INDUSTRY-STANDARD SERVERS TECHNOLOGY BRIEF (627 ko)
   HP PROLIANT DL140 G3 SERVER INTRODUCING LOGICAL SERVERS: MAKING DATA CENTER INFRASTRUCTURES MORE ADAPTIVE (624 ko)
   HP PROLIANT DL140 G3 SERVER IMPORTANT INFORMATION SMART ARRAY P-SERIES BATTERY PACK INSTALLATION FOR THE S (302 ko)
   HP PROLIANT DL140 G3 SERVER CRITICAL FACTORS IN INTRA-RACK POWER DISTRIBUTION PLANNING FOR HIGH-DENSITY SYST (435 ko)
   HP PROLIANT DL140 G3 SERVER IMPLEMENTING MICROSOFT WINDOWS SERVER 2003 WITH SERVICE PACK 2 ON PROLIANT SERV (422 ko)
   HP PROLIANT DL140 G3 SERVER INSTALLING MICROSOFT WINDOWS COMPUTE CLUSTER SERVER 2003 ON PROLIANT SERVERS US (151 ko)
   HP PROLIANT DL140 G3 SERVER SERVER VIRTUALIZATION TECHNOLOGIES FOR X86-BASED BLADESYSTEM AND PROLIANT SERV (1067 ko)
   HP PROLIANT DL140 G3 SERVER BLADESYSTEM MANAGEMENT PACK VERSION 1.0 FOR MICROSOFT® SYSTEM CENTER ESSENTIALS (495 ko)

Manual abstract: user guide HP PROLIANT DL140 G3 SERVER

Detailed instructions for use are in the User's Guide.

[. . . ] 5 Managing arrays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Adding or deleting a hotspare . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Configuring a drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Rebuilding an array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] (Optional) Enter a label of no more than 15 characters to identify the array. If you are creating a RAID 0 array, select the stripe size that you want the array to use. Available stripe sizes are 16, 32, and 64 KB (the default setting). Select one of the options listed under the Create Using heading to determine the method that the controller is to use to build the array. Table 1 describes typical circumstances for which each method is appropriate. CAUTION: Do not interrupt the creation of a RAID 0 array using the Migrate method. If you do, there is no way to restart the array creation or to recover the data that was on the source drive. CAUTION: Do not use the Migrate or Build methods to create an array on Microsoft® Windows® dynamic disks (volumes). These methods cause data loss in this case. Table 1 Choosing a method for creating the array RAID level 0 0 Method No Init Migrate Method is appropriate for. . . Creating a RAID 0 array when you want to preserve data on an existing drive. If you select this option, you are asked to designate the source drive. The contents of the source drive are preserved and any data on the new drive is lost. Creating a RAID 1 array when you want to preserve data on an existing drive. If you select this option, you are asked to designate the source drive. The contents of the source drive are preserved and any data on the new drive is lost. Creating a RAID 1 array on new drives, or when you want to be sure that the new array contains no existing data. This is the fastest way to create a RAID 1 array. 1 Build 1 1 Clear Quick Init NOTE: · · · · If you pause a Build or Clear process on a RAID 1 array, you can restart the process by pressing the Ctrl+R keys. A RAID 1 array created using the Quick Init option might return some data miscompares if you later run a consistency check. This is normal and is not a cause for concern. You can use drives of different sizes in a RAID 1 array. However, during a Build operation, only the smaller drive can be selected as the source drive. When migrating from single volume to a RAID 0 array, migrating from a larger drive to a smaller drive is allowed. However, the destination drive must have at least half the capacity of the source drive. Click Done. 12. Managing arrays With the Manage Arrays option, you can: · · · View array properties Make an array bootable Delete an array Viewing array properties 1. [. . . ] There are two ways to perform a rebuild: · · Shut down the system, replace the failed drive, and begin the rebuild at the next system restart. Add a hotspare to the array if necessary, and select the array for a manual rebuild. Configuring an array 7 System shutdown rebuild 1. Replace the failed drive with a new one of equal or greater capacity. At the appropriate prompt during POST, press the Ctrl+A keys or the F8 key to access the RAID Configuration Utility. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HP PROLIANT DL140 G3 SERVER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HP PROLIANT DL140 G3 SERVER will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag