User manual HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH APPLICATION NOTES FOR THE STORAGEWORKS B-SERIES ISCSI DIRECTOR BLADE - FC4-16IP

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH. We hope that this HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH user guide will be useful to you.

Lastmanuals help download the user guide HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH.


Mode d'emploi HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH
Download

You may also download the following manuals related to this product:

   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH STORAGEWORKS FABRIC OS 5.3.1A RELEASE NOTES (AA-RWEYJ-TE, MAY 2008) (382 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH STORAGEWORKS FABRIC OS 6.0.0B RELEASE NOTES (5697-7345, APRIL 2008) (339 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH BROCADE ACCESS GATEWAY ADMIN GUIDE V6.1.0 (53-1000605-02, JUNE 2008) (820 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH STORAGEWORKS FABRIC OS 5.3.1 RELEASE NOTES (AA-RWEYI-TE, MARCH 2008) (456 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH STORAGEWORKS FABRIC OS 6.0.1A RELEASE NOTES (AA-RWFMA-TE, JUNE 2008) (352 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH STORAGEWORKS SAN DIRECTOR INSTALLATION GUIDE (A7393-90009, MAY 2007) (7822 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH BROCADE WEB TOOLS ADMINISTRATOR'S GUIDE (53-1000606-01, OCTOBER 2007) (3241 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH BROCADE ERROR MESSAGE REFERENCE GUIDE V6.1.0 (53-1000600-02, JUNE 2008) (4257 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH BROCADE FABRIC OS MIB REFERENCE GUIDE V6.1.0 (53-1000602-02, JUNE 2008) (4485 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH STORAGEWORKS FABRIC MANAGER 5.5 RELEASE NOTES (AA-RWFHB-TE, JUNE 2008) (239 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH STORAGEWORKS FABRIC OS 6.X ADMINISTRATOR GUIDE (5697-7344, MARCH 2008) (6262 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH BROCADE FABRIC MANAGER ADMINISTRATOR'S GUIDE (53-1000610-01, APRIL 2008) (7784 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH STORAGEWORKS FABRIC OS 6.1.X ADMINISTRATOR GUIDE (5697-7477, JUNE 2008) (5768 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH BROCADE WEB TOOLS ADMINISTRATOR'S GUIDE V6.1.0 (53-1000606-02, JUNE 2008) (3409 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH STORAGEWORKS FABRICMANAGER 5.4.0A RELEASE NOTES (AA-RWFHA-TE, MARCH 2008) (199 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH BROCADE ACCESS GATEWAY ADMINISTRATOR'S GUIDE (53-1000605-01, OCTOBER 2007) (649 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH BROCADE FABRIC OS COMMAND REFERENCE GUIDE V6.1.0 (53-1000599-02, JUNE 2008) (5914 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH BROCADE FABRIC WATCH ADMINISTRATOR'S GUIDE V6.1.0 (53-1000601-02, JUNE 2008) (1347 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH BROCADE EZSWITCHSETUP ADMINISTRATOR'S GUIDE V6.1.0 (53-1000607-02, JUNE 2008) (1571 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH BROCADE TROUBLESHOOTING AND DIAGNOSTICS GUIDE V6.1.0 (53-1000853-01, JUNE 2008) (1317 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH BROCADE FABRIC MANAGER ADMINISTRATOR'S GUIDE V6.1.0 (53-10000610-02, JUNE 2008) (8499 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH BROCADE FABRIC OS MESSAGE REFERENCE SUPPORTING FABRIC OS V6.0.0 (53-1000600-01, (4691 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH BROCADE FABRIC OS MIB REFERENCE SUPPORTING FABRIC OS V3.1.X, V3.2.X, V4.1.X, V4. (3533 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH BROCADE OS COMMAND REFERENCE MANUAL SUPPORTING FABRIC OS V6.0.0 (53-1000599-01, (5806 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH THE 4/48 SAN DIRECTOR BLADE TECHNICAL DIFFERENCES WITH THE 4/16 AND 4/32 SAN DIR (24 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH BROCADE ISCSI GATEWAY SERVICE ADMINISTRATOR'S GUIDE - SUPPORTING FABRIC OS V5.3. (868 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH STORAGEWORKS 4GB SAN DIRECTOR PORT BLADE INSTALLATION INSTRUCTIONS (A7990-90003 (1077 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH STORAGEWORKS B-SERIES MULTI-PROTOCOL ROUTER BLADE INSTALLATION GUIDE (A7990-900 (1215 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH STORAGEWORKS B-SERIES SAN DIRECTOR INTELLIGENT BLADE INSTALLATION INSTRUCTIONS (439 ko)
   HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH STORAGEWORKS SAN DIRECTOR CABLE MANAGEMENT COMB INSTALLATION INSTRUCTIONS (AG56 (432 ko)

Manual abstract: user guide HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCHAPPLICATION NOTES FOR THE STORAGEWORKS B-SERIES ISCSI DIRECTOR BLADE - FC4-16IP

Detailed instructions for use are in the User's Guide.

[. . . ] Government under vendor's standard commercial license. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. [. . . ] Normally the storage is presented to the server. In this case, however, you must first get the FC storage to the FC4­16IP; the FC storage as virtual target is then allowed access to iSCSI initiators. When the FC4­16IP is configured, each iSCSI port has one FC virtual initiator exposed. FC virtual initiators are in fact the iSCSI virtual initiators. Since HP Fibre Channel storage arrays use access control (selective presentations), iSCSI virtual initiators are treated as FC hosts in every FC storage and are allowed access by selectively presenting the LUNs to those virtual initiators. Depending on the storage array, LUNs must now be created and presented to the iSCSI virtual initiators. This document describes how to serve storage from each supported storage array (MSA, EVA, and XP) to the FC4­16IP. Application Notes for the HP StorageWorks B-series iSCSI Director Blade (FC4­16IP) 5 This document assumes the reader to be experienced in the initial setup of storage arrays and in the creation of storage volumes or LUNs. If you lack this experience, you should review the configuration, user, and reference documentation for your storage array. NOTE: The iscsiCfg --easycreate tgt --s command in FC4­16IP lists all configured iSCSI virtual initiators. These virtual initiators are considered FC hosts in HP Fibre Channel storage. Presenting MSA 1500 LUNs to the FC4­16IP MSA storage volumes must be configured before LUNs can be detected and recognized by the FC4­16IP. The MSA can be configured either through its serial port or through the Array Configuration Utility. Whatever method is used, you must also use the MSA selective storage presentation (SSP) commands to restrict access to volumes that are to be served to the FC4­16IP. The following basic configuration tasks are listed in sequence (they are specified in detail in the HP Array Configuration Utility User Guide and the Configuring Arrays on HP Smart Array Controllers -- Reference Guide): · Creating the arrays (LUNs). · Entering controller settings, such as setting the read/write cache ratio, setting the rebuild/expand priority, and setting the redundancy level. · Identifying the operating system type (also called host mode, access mode, profile, and connection profile); select the iSCSI virtual initiator operating system type as Linux. · Verifying that the FC4­16IP iSCSI virtual initiator with access to the MSA is visible to the MSA. · Entering selective storage presentation options (also called access control lists) to protect the storage from unauthorized access. Settings indicate which LUNs the iSCSI virtual initiator can access. Presenting EVA 3000/5000 and EVA 4000/6000/8000 LUNs to the FC4­16IP Virtual disks are set up and presented to the host server to test connectivity and to begin using the disks. [. . . ] Set the Fibre Channel HOST MODE: 00 (to reflect Linux) and a separate host group. Select the Fabric and Connection mode parameter settings. Use secure manager to present to the FC4­16IP iSCSI virtual initiator. iSCSI target gateway scalability guidelines Table 1 provides the scalability guidelines. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HP STORAGEWORKS 4/256 SAN DIRECTOR SWITCH will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag