User manual HP STORAGEWORKS 7100 VIRTUAL ARRAY APPENDIX A. DISK ARRAY CONTROLLER LOG
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HP STORAGEWORKS 7100 VIRTUAL ARRAY. We hope that this HP STORAGEWORKS 7100 VIRTUAL ARRAY user guide will be useful to you.
Lastmanuals help download the user guide HP STORAGEWORKS 7100 VIRTUAL ARRAY.
You may also download the following manuals related to this product:
HP STORAGEWORKS 7100 VIRTUAL ARRAY LINUX CONFIGURATION VA 7100/7400 (73 ko)
HP STORAGEWORKS 7100 VIRTUAL ARRAY DISK DRIVE AND POWER SUPPLY LED BEHAVIOR (104 ko)
HP STORAGEWORKS 7100 VIRTUAL ARRAY DISK SYSTEM/CONFIGURATION SPECIFIC INSTRUCTIONS (186 ko)
HP STORAGEWORKS 7100 VIRTUAL ARRAY DISK HARDWARE COMPONENT REPLACEMENT INSTRUCTIONS (1107 ko)
HP STORAGEWORKS 7100 VIRTUAL ARRAY POWER SUPPLY SYSTEM/CONFIGURATION SPECIFIC INSTRUCTIONS (318 ko)
HP STORAGEWORKS 7100 VIRTUAL ARRAY POWER SUPPLY HARDWARE COMPONENT REPLACEMENT INSTRUCTIONS (1236 ko)
HP STORAGEWORKS 7100 VIRTUAL ARRAY STORAGEWORKS VIRTUAL ARRAY FAMILY RACK INSTALLATION GUIDE (THIS MANUAL ALSO COV (2303 ko)
HP STORAGEWORKS 7100 VIRTUAL ARRAY STORAGEWORKS VIRTUAL ARRAYS VA 7000 FAMILY INSTALLATION FLOWCHART (THIS MANUAL (50 ko)
Manual abstract: user guide HP STORAGEWORKS 7100 VIRTUAL ARRAYAPPENDIX A. DISK ARRAY CONTROLLER LOG
Detailed instructions for use are in the User's Guide.
[. . . ] Disk Array Controller Log
The array controller continually monitors all components of the disk array, and logs any information that may be of helpful in evaluating the performance and operation of the array. All aspects of array operation are logged, including: · changes to the operating status of the array · changes to the configuration of the array · performance data · port error statistics Table 1 lists all event codes that can appear in the controller log event pages. The table also includes events that are not logged, but can still generate SCSI sense data. Appropriate corrective action is included for all events that require it. [. . . ] This message is logged when NV-SDRAM is found to be invalid at boot and must be initialized. This should not cause concern if memory was purposely invalidated or a new board or new memory has just been installed. This error code indicates that a battery has failed the long discharge test. This test occurs following power on and every 30 days thereafter. The test takes about 36 hours to complete. This error code indicates that a fan has failed. This error code indicates that a power supply has failed. This error code indicates that the Background N N N N N N N N N N N N N Logged?Event Number (dec/hex) Event Name Predictive Maintenance Implication Suspected Components Description
314/0x13a
Drive Missing At Power On
Y
Ignore unless no Operator activity
Disk Drive, Controller, Back End FC Link
315/0x13b
RAM Image Upload Failed
Y
Single Occurrance
316/0x13c
Old Cache Configuration Used
Y
Ignore - See errors associated with shut down
Disk Drives, Controller, Back End FC Link None
317/0x13d
Incompatible RAM Image Content
Y
Ignore - Operator error
None
318/0x13e
Disk Interface Underrun Event
Y
319/0x13f
Disk Interface Overrun Event
Y
320/0x140
Disk Interface Timeout Event
Y
321/0x141
Controller ECC Miscorrection
Y
Single Occurrance not with other entries Single Occurrance not with other entries > 2 occurrances per hot plug insert or removal Single Occurrance Single Occurrance
Disk, controller, disk interface Disk, controller, disk interface Disk, controller, disk interface SIMM, Controller Controller
322/0x142
Controller Data Bus Microprocessor Access Error
Y
323/0x143
Incompatible Address Table In RAM Image
Y
Ignore - Operator error
None
324/0x144
Non-Volatile Memory Initialized
Y
Ignore unless no operator activity
SDRAM DIMM, Controller
325/0x145
Battery Failed Discharge Test
Y
Single Occurrance
Battery
326/0x146 327/0x147
Fan Failed Power Supply Failed
Y Y
Single Occurrance Single Occurrance Single
328/0x148
Power Down Due To Fan
Y
Fan, Controller, Backplane Power Supply, Controller, Backplane Fans,
Failure
Occurrance
Controller, Backplane
Mfg Fail?N N N N Manager (BGM) has discovered that there are not enough good fans to cool the system. The BGM is shuttingThe NVRAM is not posted to disk, so it is critical to repair the system quickly. This error code indicates that the BGM has started timing that a fan is missing from the enclosure. The total length of time a fan has been missing will be checked periodically and if it exceeds TIME_FAN_MISSING_ALLOWED_BGM (approx. 10 minutes) the BGM will shut off the power supply. This error code indicates that the BGM is shutting off the power supply because a fan has been missing from the enclosure for too long (approx. This error code indicates that the batteries have failed a discharge test or have dropped below an acceptable voltage level. Attempting to shrink write cache with valid writes still in cache. This error code indicates that a controller was discovered to be bad during the poweron process This can be caused by the controller having difficulty in establishing communication. Ignore if recovered by power cycle or reset. This error code indicates that a SIMM was discovered to be bad during the poweron process. A backend SCSI channel was held reset longer than the time allowed for a drive hotplug. Probably caused by a partially inserted drive module, a failing drive, a failing controller, or a bent pin on a connector. [. . . ] Check the extended event information for more information. A PDM, during instantiation, came up with different basic information. One possible cause is downloading unsupported mech FW that doesn't conform to the required capacity point for drive category. The midplane EEPROM mode parameters region contains a revision that is older than the revision expected by current firmware. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HP STORAGEWORKS 7100 VIRTUAL ARRAY
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HP STORAGEWORKS 7100 VIRTUAL ARRAY will begin.