User manual HP STORAGEWORKS ARRAY CONTROLLER HSG V8.7 SOFTWARE STORAGEWORKS HSG80 ARRAY CONTROLLER V8.7 COMMAND LINE INTERFACE REFERENCE GUIDE
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HP STORAGEWORKS ARRAY CONTROLLER HSG V8.7 SOFTWARE. We hope that this HP STORAGEWORKS ARRAY CONTROLLER HSG V8.7 SOFTWARE user guide will be useful to you.
Lastmanuals help download the user guide HP STORAGEWORKS ARRAY CONTROLLER HSG V8.7 SOFTWARE.
You may also download the following manuals related to this product:
HP storageworks array controller hsg v8.7 software annexe 1 (4024 ko)
HP storageworks array controller hsg v8.7 software annexe 2 (2648 ko)
HP STORAGEWORKS ARRAY CONTROLLER HSG V8.7 SOFTWARE STORAGEWORKS HSG80 ENTERPRISE/MODULAR STORAGE RAID ARRAY FIBRE CHANNEL SOLUTION (778 ko)
HP STORAGEWORKS ARRAY CONTROLLER HSG V8.7 SOFTWARE STORAGEWORKS HSG80 ENTERPRISE/MODULAR STORAGE RAID ARRAY FIBRE CHANNEL SOLUTION (602 ko)
HP STORAGEWORKS ARRAY CONTROLLER HSG V8.7 SOFTWARE STORAGEWORKS USING SYSTEMS INSIGHT MANAGER WITH STORAGEWORKS MANAGEMENT SOFTW (330 ko)
HP STORAGEWORKS ARRAY CONTROLLER HSG V8.7 SOFTWARE STORAGEWORKS HSG80 ACS SOLUTION SOFTWARE V8.7 FOR WINDOWS 2000 DATACENTER INSTA (4503 ko)
HP STORAGEWORKS ARRAY CONTROLLER HSG V8.7 SOFTWARE HSG80 ACS SOLUTION SOFTWARE VERSION 8.7 FOR COMPAQ OPENVMS INSTALLATION AND CONF (4224 ko)
HP STORAGEWORKS ARRAY CONTROLLER HSG V8.7 SOFTWARE STORAGEWORKS HSG80 ARRAY CONTROLLER V8.7 TROUBLESHOOTING REFERENCE GUIDE (EK-G8 (2365 ko)
Manual abstract: user guide HP STORAGEWORKS ARRAY CONTROLLER HSG V8.7 SOFTWARE STORAGEWORKS HSG80 ARRAY CONTROLLER V8.7 COMMAND LINE INTERFACE REFERENCE GUIDE
Detailed instructions for use are in the User's Guide.
[. . . ] hp StorageWorks
HSG80 Array Controller V8. 7 Command Line Interface Reference Guide
Part Number: EKG80CLRA. B01
Second Edition (August 2002) Product Version: 8. 7
This guide provides detailed descriptions of all CLI commands and step-by-step instructions on how to use each command.
© Hewlett-Packard Company, 2002. Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. [. . . ] However, a reduced RAIDset does not make the concatset inoperative. The maximum total disks in a concatset is 24. Storagesets must have been initialized before being added to the concatset. The CLONE utility cannot be used on a concatset. Concatsets cannot be used in remote copy sets.
· · · · · · · Syntax
SET concatset-name Parameters concatset-name The name of the concatset to be expanded. Switches ADD=storage-set-name
2102
HSG80 Array Controller V8. 7 Command Line Interface Reference Guide
SET concatset-name
Concatenates the storageset specified by storage-set-name to the concatset. Examples To expand the capacity of unit D0 which consists of stripeset Stripe1, by adding another stripeset (Stripe2), enter:
ADD CONCATSETS C1 STRIPE1 SET C1 ADD=STRIPE2
See Also ADD CONCATSETS DELETE concatsets SHOW CONCATSETS
HSG80 Array Controller V8. 7 Command Line Interface Reference Guide
2103
CLI Command Descriptions
SET connection-name
Changes the operating characteristics of a host connection. Each path between a Fibre Channel adapter in a host computer and an active host port on a controller is a connection. This command adds the specified host connection to the table of known connections. This table is maintained in the controller's memory. The maximum table length is 96 connections; if the table contains 96 entries, new connections cannot be added unless some old ones are deleted. The SET connection-name command changes the operating parameters of the specified host connection. A host connection is a specific instance of one host connected to one port of one controller through one host adapter. Syntax SET connection-name Parameters connection-name This is the name of the host connection. When a new host-adapter-port-controller connection is made, the new connection is given a default connection name. The default connection name is !NEWCONnn, where nn is a decimal number. The connection name can be changed through the RENAME command. Switches The following switches are available for the SET connection-name command: · · · OPERATING_SYSTEM RESERVATION_STYLE UNIT_OFFSET
These switches are described in the following paragraphs:
2104
HSG80 Array Controller V8. 7 Command Line Interface Reference Guide
SET connection-name
OPERATING_SYSTEM=OS_name Specifies the operating system of the host. The OPERATING_SYSTEM switch tailors the controller's behavior for use with a particular operating system. See your operating system specific Solution Kit to determine which value should be used. The following values are supported: WINNT, TRU64_UNIX, VMS, HP, HP_VSA, IBM, NETWARE, SGI, SNI, SUN, AIX_CAMBEX. RESERVATION_STYLE=CONNECTION_BASED (default) RESERVATION_STYLE=HBA_PORT_ID_BASED Selection of a RESERVATION_STYLE should be based upon the capabilities of the host operating system. [. . . ] A utility that allows viewing of specific informational displays using CLI commands.
wide Ultra SCSI
Fast-20 on a Wide SCSI bus.
HSG80 Array Controller V8. 7 Command Line Interface Reference Guide
Glossary27
Glossary
worldwide name
A unique 64-bit number assigned to a subsystem by the Institute of Electrical and Electronics Engineers (IEEE) and set by DIGITAL manufacturing prior to shipping. Also called node ID within the CLI.
write hole
The period of time in a RAID level 1 or RAID level 5 write operation when an opportunity emerges for undetectable RAIDset data corruption. Write holes occur under conditions such as power outages, where the writing of multiple members can be abruptly interrupted. A battery backed-up cache design eliminates the write hole because data is preserved in cache and unsuccessful write operations can be retried.
write-back caching
A cache management method used to decrease the subsystem's response time to write requests by allowing the controller to declare the write operation "complete" as soon as the data reaches its cache memory. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HP STORAGEWORKS ARRAY CONTROLLER HSG V8.7 SOFTWARE Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HP STORAGEWORKS ARRAY CONTROLLER HSG V8.7 SOFTWARE will begin.