User manual HP STORAGEWORKS XP ARRAY MANAGER SOFTWARE
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HP STORAGEWORKS XP ARRAY MANAGER SOFTWARE. We hope that this HP STORAGEWORKS XP ARRAY MANAGER SOFTWARE user guide will be useful to you.
Lastmanuals help download the user guide HP STORAGEWORKS XP ARRAY MANAGER SOFTWARE.
You may also download the following manuals related to this product:
HP storageworks xp array manager software annexe 1 (1571 ko)
HP storageworks xp array manager software annexe 4 (369 ko)
HP storageworks xp array manager software annexe 5 (361 ko)
HP storageworks xp array manager software annexe 8 (478 ko)
HP storageworks xp array manager software annexe 10 (1225 ko)
HP storageworks xp array manager software annexe 11 (511 ko)
HP storageworks xp array manager software annexe 12 (2050 ko)
HP STORAGEWORKS XP ARRAY MANAGER SOFTWARE STORAGEWORKS XP COMMAND VIEW ADVANCED EDITION SOFTWARE 6.0 SERVER INSTALLATION (2255 ko)
Manual abstract: user guide HP STORAGEWORKS XP ARRAY MANAGER SOFTWARE
Detailed instructions for use are in the User's Guide.
[. . . ] Hitachi Cache Manager User's Guide
Hitachi Universal Storage Platform V Hitachi TagmaStore® Universal Storage Platform Hitachi TagmaStore® Network Storage Controller Hitachi Lightning 9900TM V Series Hitachi Lightning 9900TM
FAS T FIND LINK S
Document Organization Product Version Getting Help Contents
HIT1642-96001
ii Hitachi Cache Manager User's Guide
Contents
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi Product Version. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi Document Revision Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] See the glossary for status definitions. Figure 4-9 illustrates STATUS command parameters.
· ·
You can specify target data by DDNAME, (using volume, unit and disp number), VOLUME (volume serial number) or DEVICE (device number). You can specify a target data range as either DKU (a volume defined by DDNAME or volume) or DKC (all volumes in the same storage system ID). (DKU is the default value. ) EXTENT specifies that cache extent information will be printed. NOEXTENT specifies that cache extent information will not be printed. (NOEXTENT is default value. ) DSEXTENT specifies that extent information of dataset statistics will be printed. If this is combined with a DKC command, you must also define RAIDPARM.
(dd name) (volume serial number) (device number) | DKC ] | NOEXTENT | DSEXTENT ]
· · ·
DDNAME VOLUME DEVICE [ DKU [ EXTENT
Figure 4-9
STATUS Command Parameters
Figure 4-10 is an example of a cache memory STATUS report.
** CACHE MANAGER UTILITY 10:01:05 PAGE 0001 STATUS VOL (RAID31) DKC (P-9Y2R-J91Y1 01-02-07) ** LISTING INFORMATION 2000-03-23, CACHE SUBSYSTEM STATUS REPORT SSID---- X'0080' NVS ENABLED DEVICE ADDRESS---- X'01' PINNED DATA NONE 2097152 2097152 4194304 1024
DISK CONTROLLER INFORMATION CU-TYPE---- 3990-3 CACHE STATUS ENABLED
FLASH ACCESS CONFIGURATION REMAINING AREA USED AREA FLASH ACCESS AVAILABLE USED AREA COUNT
Figure 4-10
Cache Memory STATUS Report
Performing Cache Manager Operations Hitachi Cache Manager User's Guide
4-9
Figure 4-11 is an example of a cache extent STATUS report.
** CACHE MANAGER UTILITY 10:01:05 PAGE 0001 STATUS VOL(RAID31) DKU (P-9Y2R-J91Y1 01-02-07) ** LISTING INFORMATION 2000-03-23,
CACHE EXTENT STATUS REPORT
VOLSER--RAID31 DEVICE NUMBER---- X'2001' DEVICE TYPE----3390-3 SSID----X'0094' DEVICE ADDRESS---- X'01' CACHE ACCESS--ENABLED DRIVE STATUS--ENABLED DFW STATUS----- ENABLED USED AREA COUNT-- 5 ----FROM-------TO-------SIZE-------DCR---- --EXTENT--- -DATASET NAME--CC HH CC HH CYLS HEADS TYPE RELATION 00000-0001 00010-0001 10 1 BIND ALL USER1. AAAA. BBBB. CCCC 00050-0000 00100-0014 51 0 PRIO PART USER1. AAAA. BBBB. DDDD 00128-0000 00160-0008 32 9 BIND PART USER1. AAAA. BBBB. DDDD 01000-0000 01009-0014 10 0 PRIO ALL USER1. AAAA. BBBB. EEEE 01010-0000 01010-0014 1 0 PRIO ALL *** VTOC **** 01011-0000 01011-0014 1 0 PRIO ALL SYS1. VTOCIX. RAID31 01012-0000 01012-0014 1 0 PRIO ALL SYS1. VVDS. VRAID31 01013-0000 01013-0014 1 0 BIND ALL ***FREE SPACE ***
Figure 4-11
Cache Extent STATUS Report
Figure 4-12 is an example of a CLPR for Cache Residency Manager STATUS report.
** CACHE MANAGER UTILITY 02-16, 10:01:05 PAGE 0001 STATUS VOL(RAID31) CLPR (P-9Y2R-J91Y1 01-06-03) ** LISTING INFORMATION CACHE SUBSYSTEM STATUS REPORT SSID---- X'0080' CACHE ENABLED DEVICE ADDRESS---- X'01' NVS ENABLED 2005-
DISK CONTROLLER INFORMATION CU-TYPE---- 3990-3 PINNED DATA STATUS NONE
CLPR NO. 32 CURRENT CLPR CONFIGRATION REMAINING AREA USED AREA FLASH ACCESS AVAILABLE MAXIMUM AREA COUNT USED AREA COUNT DEVICE USED AREA COUNT
2000000 2000000 4000000 2048 1024 512
Figure 4-12
CLPR Extent STATUS Report
4-10
Performing Cache Manager Operations Hitachi Cache Manager User's Guide
Figure 4-13 is an illustration of a JCL for volume STATUS.
(1) (2) (3) (4) (5) (6) (7)
(8) (9) (1) (2) (3) (4) (5) (6)
//CSUT13 JOB MSGLEVEL=(1, 1) //CACHE EXEC PGM=HRUDCRX, REGION=1024K //SYSPRINT DD SYSOUT=A //RAIDPARM DD DSN=input dataset name, VOL=SER=volume serial number, // UNIT=SYSDA, DISP=SHR //SYSIN DD * STATUS VOLUME(CSVOL2) DKU STATUS VOLUME(CSVOL3) DKC EXTENT /* //
Start of job. Define a dataset to store the device number. Define a dataset to store the control statements. Edit the cache status, nonvolatile memory status and capacity information and store them in the dataset. VOLUME defines a volume serial number in the cache storage system. DKU is a required parameter to specify the entire volume of `CSVOL2'. (7) Edit the cache status and extent information and store them in the dataset. VOLUME defines a volume serial number in the cache storage system. DKC specifies all volumes with the same storage system ID (SSID). This is necessary to define the RAIDPARM DD statement. EXTENT defines the cache extent as all volumes that belong to same storage system ID (SSID). (9) End of job.
Figure 4-13
Volume STATUS Command
Performing Cache Manager Operations Hitachi Cache Manager User's Guide
4-11
Figure 4-14 illustrates a sample JCL for a dataset STATUS command. Cache Manager stores, edits and prints the extent information (dataset statistics) for all volumes, including a specified volume with the same storage system ID (SSID).
(1) (2) (3) (4) (5) (6) (7)
(8) (9) (1) (2) (3) (4) (5) (6)
//CSUT23 JOB MSGLEVEL=(1, 1) //CACHE EXEC PGM=HRUDCRX, REGION=1024K //SYSPRINT DD SYSOUT=A //RAIDPARM DD DSN=input dataset name, VOL=SER=volume serial number, // UNIT=SYSDA, DISP=SHR //SYSIN DD * STATUS VOLUME(CSVOL2) DKU DSEXTENT STATUS VOLUME(CSVOL3) DKC DSEXTENT /* //
Start of job. Define a dataset to store the device number. Define a dataset to store the control statements. [. . . ] Areas used for Cache Residency or Cache Manager. Other names for this product are: FlashAccess, Dynamic Cache Residency (DCR). Cache error occurred, so cache function has been stopped. cache status is being changed to "enabled". [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HP STORAGEWORKS XP ARRAY MANAGER SOFTWARE
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.