User manual HP STORAGEWORKS XP PERFORMANCE ADVISOR SOFTWARE STORAGEWORKS PERFORMANCE ADVISOR XP SOFTWARE RELEASE NOTES (T1789-96034, FEBRUA

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HP STORAGEWORKS XP PERFORMANCE ADVISOR SOFTWARE. We hope that this HP STORAGEWORKS XP PERFORMANCE ADVISOR SOFTWARE user guide will be useful to you.

Lastmanuals help download the user guide HP STORAGEWORKS XP PERFORMANCE ADVISOR SOFTWARE.


Mode d'emploi HP STORAGEWORKS XP PERFORMANCE ADVISOR SOFTWARE
Download

You may also download the following manuals related to this product:

   HP storageworks xp performance advisor software annexe 2 (8451 ko)
   HP storageworks xp performance advisor software annexe 3 (652 ko)
   HP storageworks xp performance advisor software annexe 4 (6115 ko)
   HP STORAGEWORKS XP PERFORMANCE ADVISOR SOFTWARE STORAGEWORKS PERFORMANCE ADVISOR XP SOFTWARE 3.3 INSTALLATION GUIDE (T1789-9602 (452 ko)
   HP STORAGEWORKS XP PERFORMANCE ADVISOR SOFTWARE STORAGEWORKS PERFORMANCE ADVISOR XP SOFTWARE INSTALLATION GUIDE (T1789-96032, J (590 ko)
   HP STORAGEWORKS XP PERFORMANCE ADVISOR SOFTWARE STORAGEWORKS PERFORMANCE ADVISOR XP SOFTWARE TROUBLESHOOTING GUIDE (T1789-96033 (287 ko)

Manual abstract: user guide HP STORAGEWORKS XP PERFORMANCE ADVISOR SOFTWARE STORAGEWORKS PERFORMANCE ADVISOR XP SOFTWARE RELEASE NOTES (T1789-96034, FEBRUA

Detailed instructions for use are in the User's Guide.

[. . . ] HP StorageWorks Performance Advisor XP release notes Part number: T1789-96034 First edition: February 2008 Legal and notice information © Copyright 1999, 2008 Hewlett-Packard Development Company, L. P. Description The HP StorageWorks Performance Advisor XP (PA XP) software is a web-based application that enables you to collect and monitor real-time performance data from the HP StorageWorks family of XP disk array products. The simple browser-based interface of PA XP enables you to customize performance data collection and set performance alarms. PA XP provides real-time and historical data on the following: · LDEV I/O · Front-end and back-end utilization · Internal bus utilization · Cache usage This release notes discusses the new features and enhancements introduced in PA XP 3. 4, and the known limitations in this release. Devices supported The PA XP software supports all HP XP disk arrays. Firmware requirements Following are the minimum firmware levels that the managed disk arrays must meet: XP24000/XP20000 SVS200 XP10000/XP12000 XP1024/XP128 XP512/XP48 XP256 Firmware version 60. 01. 31. 00/00 or later Firmware version 50. 07. 69. 00/00 or later Firmware version 50. 09. 34. 00/00 or later Firmware version 21. 14. 30. 00/00 or later Firmware version 01. 19. 99. 00/02 or later Firmware version 52. 49. 40. 00/00 or later Operating systems Following are the supported operating system versions for the management station and the host agents: · Windows Server 2003 Standard, Enterprise Edition R2 (IA-32 only) (Service Pack 1, Service Pack 2) · Windows XP Professional (Service Pack 2) · Windows Vista (IA-32 only) · Windows Server 2003 Standard, Enterprise Edition (IA-32 only) (Service Pack 1, Service Pack 2) · Windows 2003 Enterprise Edition (IA-32 and IA-64) (Service Pack 1, Service Pack 2) · Windows 2003 Data Center Edition (IA-64) · Windows Server 2003 Enterprise Edition R2 (IA-32) (Service Pack 1, Service Pack 2) For Management Station Microsoft Windows For Host Agents Microsoft Windows HP StorageWorks Performance Advisor XP release notes 3 HP-UX · HP-UX 1 1 with the following PA-RISC patches: 1. 1 · PHCO_24777 · PHKL_24253, 24254, 24256, 24551, 24751 · PHNE_24035 · HP-UX 1 1. 23 (IA-64) · HP-UX 1 1. 23 (PA-RISC) · HP-UX 1 1. 31 (PA-RISC) · HP-UX 1 1. 31 (IA-64) Sun Solaris 8, 9, 10 (SPARC) SUSE Linux Enterprise Server 8 (kernel: 2. 4. 21) (IA-32) IBM AIX 5. 2, 5. 3 Red Hat Enterprise Linux 4. 0 (IA-32) and (IA-64), Kernel version 2. 6. 9 Sun Solaris SUSE Linux IBM AIX Red Hat Enterprise Linux Languages The PA XP software is available in English language only. New features This section discusses the new features introduced in PA XP 3. 4. Support for XP24000 array · The number of LDEVs per Logical DKC is 65536. [. . . ] · Maximum database size is 64 GB. · Incremental interval of database size is 2 GB (automatically increased). · Incremental interval of database size is 1 GB (manually increased). · Cache size is 10% of the database size. · Minimum cache size is 400 MB and the maximum cache size is 2 GB. Others · XP24000 cache partitions are supported in addition to XP10000, XP12000, and XP20000 cache partitions. 6 · Reports can be displayed in the RTF file format. Installing and uninstalling PA XP 3. 4 For information on prerequisites, and installation and uninstallation procedures for PA XP 3. 4, see the HP StorageWorks Performance Advisor XP Software installation guide. Upgrading to PA XP 3. 4 For information on prerequisites and procedures for upgrading earlier versions of PA XP, see the HP StorageWorks Performance Advisor XP Software installation guide. NOTE: To upgrade from 2. 2B without losing the current data, you must first upgrade the management station to PA XP 3. 3 or later, and then upgrade to PA XP 3. 4. Patch related information Following are the patches included in PA XP 3. 4 release: Patch PA XP 3. 3-1 Description This patch provides a fix for the following defect: the usergrp command fails even if the specified CU:LDEV exists. This patch provides a fix for the following defect: PA XP logs the error, "SOLID Table Error 13039: Illegal assignment from type DOUBLE PRECISION to type SMALLINT" in the Event log file. As a result, data collection fails for both Inband and Outband data collection processes. This patch provides a fix for the following defect: The hour of the Day report is configured to display the collected data points across time intervals in a 24-hour format. On occasions where the data points are not collected for 24 hours, the report also displays interim time intervals to maintain continuity of time stamps on the X-axis and complete the 24-hour format. PA XP 3. 3. 1-1 PA XP 3. 3. 1-2 Points to note This section describes important information related to PA XP 3. 4: · · · · · · · · PA XP and CV XP co-existence is not supported. Starting with PA XP 3. 4, remote deployment of the host agent is not supported. Integration of Tiered Storage Manager (TSM) with PA XP. · If the Perf_DBUpgrade. bat file is executed during the upgrade process, the following message might be displayed: java. sql. SQLException: [Solid JDBC 04. 20. 0022] SOLID Table Error 13011: Table Error 13011: Table <XXXX>_OLD does not exist You can ignore this message because the data points are converted successfully. · Installation procedure on Windows Vista platform: User Account Control (UAC) is a new security component available in Windows Vista. UAC enables you to perform common tasks as administrators and non-administrators (standard users) without switching the roles, logging off from the system, or using the Run As option. nl nl UAC controls the program(s) installation and uninstallation, and prevents programs from being added to the registry. Complete the steps for installing PA XP 3. 4 on a Windows Vista management station: Go to Start > Run and type msconfig in the textbox. The System Configuration window displays. On the System Configuration window, click the Tools tab. Select the Disable UAC row and click Launch. Reboot the system for the changes to get activated. After the installation is completed, go to Start > Run and type msconfig in the textbox again. [. . . ] · A 32-bit application cannot access the System32 folder on a system that is running a 64-bit version of Windows Server 2003. However, because of this defect in Windows Server 2003 SP2, some scenarios may fail if the application attempts to access the library file in the System32 path. For example, the RAID type is not displayed on a IA 64 bit Windows 2003 SP2 system. Workaround: Microsoft recommends that you install the next Windows Server 2003 service pack that provides the hotfix for this problem. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HP STORAGEWORKS XP PERFORMANCE ADVISOR SOFTWARE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HP STORAGEWORKS XP PERFORMANCE ADVISOR SOFTWARE will begin.

Search for a user manual

 