Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HP SURESTORE SCSI-FC BRIDGES. We hope that this HP SURESTORE SCSI-FC BRIDGES user guide will be useful to you.
Lastmanuals help download the user guide HP SURESTORE SCSI-FC BRIDGES.
You may also download the following manuals related to this product:
HP surestore scsi-fc bridges annexe 1 (1307 ko)
HP SURESTORE SCSI-FC BRIDGES FIBRE CHANNEL PRIMER (837 ko)
HP SURESTORE SCSI-FC BRIDGES CONTROL PANEL QUICK REFERENCE (75 ko)
HP SURESTORE SCSI-FC BRIDGES SAN SOLUTION INSTALLATION GUIDE (398 ko)
HP SURESTORE SCSI-FC BRIDGES NETWORK STORAGE ROUTER IMPLEMENTATION ISSUES - APPLICATION NOTES (477 ko)
HP SURESTORE SCSI-FC BRIDGES SURESTORE BRIDGE FC 2/1 LV AND FC 4/1 HV INSTALLATION AND OPERATIONS GUIDE (2540 ko)
Manual abstract: user guide HP SURESTORE SCSI-FC BRIDGES
Detailed instructions for use are in the User's Guide.
[. . . ] Service and User Manual
Hewlett-Packard SureStore E SCSI Bridge FC 4/2
+HZOHWW3DFNDUG 6XUH6WRUH ( 6&6, %ULGJH )&
KS+
(GLWLRQ ( 2UGHU 1R $ 3ULQWHG LQ 86$
Notice
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
Format Conventions
'HQRWHV
Note
FRPPDQG
6LJQLILFDQW FRQFHSWV RU RSHUDWLQJ LQVWUXFWLRQV 7H[W WR EH W\SHG YHUEDWLP DOO FRPPDQGV SDWK QDPHV ILOH QDPHV DQG GLUHFWRU\ QDPHV 7H[W GLVSOD\HG RQ WKH VFUHHQ . H\V WR EH SUHVVHG IRU H[DPSOH WKH 5HWXUQ!The FC adapter encapsulates the command in the FC protocol and sends the packet to the SSB. (2) The FC adapter in the SSB receives the packet, strips the header, interprets the FC information, and places the packet in memory. (3) The processor interprets the SCSI information and programs the appropriate SCSI and FC adapter to process the transaction. [. . . ] WR WDNH WKH 6&6, DGDSWHU DQG DOO GHYLFHV FRQQHFWHG WR WKH DGDSWHU RIIOLQH $ PHVVDJH SURPSWV IRU FRQILUPDWLRQ IRU H[DPSOH
Take SCSI bus 2 offline now?[No]
3UHVV t WR VFUROO WR <HV DQG SUHVV ENTER!LI \RX GR QRW ZDQW WR WDNH WKH DGDSWHU RIIOLQH
86
8VLQJ WKH 6&6, $GPLQ 0HQX
7KH 66% WDNHV WKH 6&6, DGDSWHU RIIOLQH $ PHVVDJH LQGLFDWHV WKH 6&6, EXV LV RIIOLQH DV IROORZV
SCSI 2 is OFFLINE
7KH 6&6, EXV VWD\V RIIOLQH XQWLO \RX SODFH LW EDFN RQOLQH 7R YHULI\ WKDW WKH 6&6, EXV LV RIIOLQH GLVSOD\ WKH 6ORW 6WDWXV 6FUHHQ DQG ORRN IRU WKH V\PERO QH[W WR WKH 6&6, DGDSWHU QXPEHU 7KH V\PERO PHDQV WKDW WKH EXV GLG QRW JR RIIOLQH , Q WKDW FDVH UHIHU WR FKDSWHU 7URXEOHVKRRWLQJ RU FRQWDFW DQ +3 6HUYLFH 5HSUHVHQWDWLYH
FC A+ B+ SCSI 0+ 1+ 2-
Ver: xxxx OK
7R 5HWXUQ WKH 6&6, $GDSWHU 2QOLQH
7KLV LQVWUXFWLRQ DVVXPHV WKH DGDSWHU LV RIIOLQH DQG \RX DUH YLHZLQJ WKH PHVVDJH 6&6, ; LV 2))/, 1( , I D GLIIHUHQW VFUHHQ LV GLVSOD\HG UHWXUQ WR WKH 6&6, $GPLQ 0HQX 7DNH 2IIOLQH RSWLRQ 3UHVV CANCEL!7KH IROORZLQJ RSWLRQ DSSHDUV 6&6, $GPLQ 0HQX >*R RQOLQH@ 3UHVV ENTER!WR SXW WKH VHOHFWHG 6&6, DGDSWHU DQG FRQQHFWHG GHYLFHV EDFN RQOLQH $ FRQILUPDWLRQ PHVVDJH DSSHDUV *R RQOLQH ZLWK 6&6, EXV QRZ" >1R@ 3UHVV t WR VFUROO WR <HV DQG SUHVV ENTER!LI \RX GR QRW ZDQW WR SXW WKH DGDSWHU RQOLQH
Using the Control Panel
8VLQJ WKH 6&6, $GPLQ 0HQX
87
3UHVV MENU!WR UHWXUQ WR WKH 0DLQ 0HQX 9HULI\ WKDW WKH 6&6, EXV LV RQOLQH E\ LQVSHFWLQJ WKH 6ORW 6WDWXV 6FUHHQ 7KH V\PERO QH[W WR WKH DGDSWHU QXPEHU PHDQV WKDW WKH DGDSWHU LV RQOLQH , I WKH V\PERO GLVSOD\V WKH EXV GLG QRW JR RQOLQH 5HIHU WR FKDSWHU 7URXEOHVKRRWLQJ RU FRQWDFW DQ +3 VHUYLFH UHSUHVHQWDWLYH
88
8VLQJ WKH 6&6, $GPLQ 0HQX
Viewing the Error Log
:KHQHYHU WKH 66% VHQVHV DQ HUURU FRQGLWLRQ LW ORJV WKH HUURU (UURUV DUH WUDFNHG E\ WKH (UURU /RJ DQG FDQ EH UHWULHYHG XVLQJ WKH 6XSSRUW 7RROV 0DQDJHU 670 VRIWZDUH SURJUDP )RU PRUH LQIRUPDWLRQ RQ 670 VHH 8VLQJ 6XSSRUW 7RROV 0DQDJHU 670 RQ SDJH 7KH IROORZLQJ LQIRUPDWLRQ GHVFULEHV KRZ WR GLVSOD\ DQG LQWHUSUHW (UURU /RJ LQIRUPDWLRQ 3UHVV MENU!WR GLVSOD\ WKH 0DLQ 0HQX RU SUHVV CANCEL!IURP DQ\ RWKHU VXEPHQX XQWLO WKH 0DLQ 0HQX DSSHDUV IRU H[DPSOH
Main Menu [SSB Status SSB]
)URP WKH WRS 66% VXEPHQX SUHVV s WZLFH WR GLVSOD\ WKH (UURU /RJ VXEPHQX
Main Menu [Error Log]
3UHVV ENTER!WR YLHZ WKH ILUVW (UURU /RJ
Error Log
PC: 0105
[No. 01: 010 PC ago]
Press <ENTER> to see the Error Message Detail screen.
Log Number
Power Cycles Ago
Current Power Cycle
)LJXUH
([DPSOH (UURU /RJ Using the Control Panel
9LHZLQJ WKH (UURU /RJ
89
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
Location of the error Manufacturing use only
SCSI 0
Err:XXXXX0XX
0012:09:59 ago
Timestamp
Character in 6th position (in this case, 0) is the Error Code.
)LJXUH
([DPSOH (UURU 0HVVDJH 'HWDLO 6FUHHQ
90
9LHZLQJ WKH (UURU /RJ
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
Using the Control Panel
9LHZLQJ WKH (UURU /RJ
91
Error Code Descriptions
7DEOH (UURU /RFDWLRQV DQG (UURU &RGH 'HVFULSWLRQV Error Code XXXXXFXX XXXXXAXX XXXXXBXX XXXXX8XX XXXXX6XX XXXXX7XX XXXXX0XX XXXXX1XX XXXXX2XX XXXXX3XX XXXXX5XX XXXXX9XX XXXXXCXX XXXXXDXX XXXXXEXX Description/Action Fan failed. See Replacing the Fans HP Qualified Personnel Only on page 147 (chapter 6). See Adding, Removing, or Replacing a SCSI Adapter on page 142. See Adding, Removing, or Replacing a SCSI Adapter on page 142. See Replacing the LCD HP Qualified Personnel Only on page 150. See Replacing the Motherboard HP Qualified Personnel Only on page 154. See Replacing a Memory Card HP Qualified Personnel Only on page 145. See Adding, Removing, or Replacing a SCSI Adapter on page 142. See Adding, Removing, or Replacing a SCSI Adapter on page 142. See Adding, Removing, or Replacing a SCSI Adapter on page 142. See Adding, Removing, or Replacing a SCSI Adapter on page 142. Contact the HP Support Center.
Error Location Fan FC A FC B LCD M_BRD MEM SCSI 0 SCSI 1 SCSI 2 SCSI 3 UNKNWN
92
(UURU &RGH 'HVFULSWLRQV
Error (ERR) Mode
, I WKH 66% VHQVHV DQ LQWHUQDO HUURU GXULQJ LWV QRUPDO IXQFWLRQV LW ORJV WKH HUURU WR DQ LQWHUQDO HUURU ORJ , Q (UURU PRGH WKH 66% FDQQRW SURFHVV GDWD EXW FDQ FRPPXQLFDWH ZLWK WKH KRVW DQG WKH 66% GLDJQRVWLFV FDQ EH UXQ , I WKH 66% JRHV LQWR D )DWDO PRGH LW VKXWV GRZQ 6HH )DWDO (UURU 0RGH RQ SDJH IRU PRUH LQIRUPDWLRQ 7KH (UURU /RJ OLVWV WKH HUURU )RU PRUH LQIRUPDWLRQ RQ HUURU ORJV DQG HUURU FRGHV VHH 9LHZLQJ WKH (UURU /RJ RQ SDJH
FC: A+ SCSI: 0+ 1-
Ver: xxxx ERR
Indicates the SSB is in error mode and only partially functional. [. . . ] , I QRW UHUXQ GLDJQRVWLF WHVWV
146
5HSODFLQJ D 0HPRU\ &DUG +3 4XDOLILHG 3HUVRQQHO 2QO\
Replacing the Fans HP Qualified Personnel Only
Adding and Replacing Parts
Caution
Only the FC and SCSI adapters are customer-replaceable parts. Replacement of other parts by non-HP qualified personnel will void the SSB's warranty.
5HTXLUHG WRROV
6WDQGDUG IODW EODGH RU 3KLOOLSV VFUHZ GULYHU 5HSODFHPHQW IDQ (6' VWUDS The power cord is the main disconnect for this product. To protect against shock hazard, always unplug the power cord before removing the cover of the SSB.
WARNING
3RZHU RII WKH 66% DQG UHPRYH WKH SRZHU FRUG 5HPRYH WKH FRYHU DQG IURQW EH]HO
$WWDFK WKH (6' VWUDS WR WKH FKDVVLV RI WKH 66% 5HPRYH WKH IDQ DVVHPEO\ VFUHZV
5HSODFLQJ WKH )DQV +3 4XDOLILHG 3HUVRQQHO 2QO\
147
'LVFRQQHFW WKH IDQ FRQQHFWRUV IURP WKH PRWKHUERDUG E\ SUHVVLQJ WKH WDE RQ WKH FRQQHFWRUV VLGH
Press Here
1RWH
%HFDXVH RI WKH FORVH SUR[LPLW\ RI WKH IDQ WR WKH )& FDUGV \RX PD\ QHHG WR XVH ORQJ QRVH SOLHUV RU KHPDVWDWV WR UHPRYH WKH IDQ
*UDVS WKH WRS RI WKH ROG IDQ XQLW DQG SXOO LW XS DQG RXW 'R QRW GLVVHPEOH WKH XQLW , QVHUW WKH QHZ IDQ
&RQQHFW WKH IDQ FDEOHV DQG LQVHUW WKH QHZ IDQ 1RWH WKH RULHQWDWLRQ RI WKH WDEV ZKHQ LQVHUWLQJ WKH PDOH DQG IHPDOH FRQQHFWRUV 5HSODFH DQG WLJKWHQ WKH VFUHZV WR VHFXUH WKH IDQ DVVHPEO\
148
5HSODFLQJ WKH )DQV +3 4XDOLILHG 3HUVRQQHO 2QO\
5HSODFH WKH IURQW EH]HO DQG WKH FRYHU 5HFRQQHFW WKH SRZHU FRUG 6HFXUH WKH FRYHU VFUHZV 3RZHU RQ WKH 66% , W ZLOO VHOI WHVW DXWRPDWLFDOO\ 6HH ZKHWKHU WKH 6ORW 6WDWXV 6FUHHQ GLVSOD\V 2. , I QRW UHUXQ GLDJQRVWLF WHVWV
Adding and Replacing Parts
5HSODFLQJ WKH )DQV +3 4XDOLILHG 3HUVRQQHO 2QO\
149
Replacing the LCD HP Qualified Personnel Only
Caution
Only the FC and SCSI adapters are customer-replaceable parts. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HP SURESTORE SCSI-FC BRIDGES
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HP SURESTORE SCSI-FC BRIDGES will begin.