If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HUSKY HRDC-U500-061117. We hope that this HUSKY HRDC-U500-061117 user guide will be useful to you.
Lastmanuals help download the user guide HUSKY HRDC-U500-061117.
Manual abstract: user guide HUSKY HRDC-U500-061117
Detailed instructions for use are in the User's Guide.
[. . . ] Ultra 500 VG-LX Plate Sizing Number of Manifold Drops Height 2-4 6 - 16
J
S
K
N
40. 00 (1. 574") 59. 1 (2. 33") 65. 0 (2. 56") 60. 00 (2. 362") 79. 1 (3. 11") 85. 0 (3. 35")
Contact Husky for more information
Please confirm all dimensions and nozzle/gating suitability with Husky prior to machining.
2006. 08
45
Ultra 500 VG-LX
Gate Detail (Plunger)
Contact Husky with any gate insert backup concerns.
Nozzle Selection
23. 8 [0. 94] 14. 8 [0. 58] Int Pt
A
METRIC IMPERIAL
10. 010 + 0. 005
0. 01 A
0. 005 0. 0002
[. 3941 + 0. 0002]
0. 0004 A
0. 8
0. 80 [0. 03]
7. 4 [0. 29]
R 0. 8
R 0. 8 [0. 03] R 0. 5 [0. 02]
8. 6 [0. 34] Int Pt
0. 4
60
15 MAX
R 0. 8 [0. 03]
1. 00 (0. 039"), 1. 20 (0. 047"), 1. 50 (0. 059") and 1. 80 (0. 071") (plunger) gates are standard, other sizes require customized parts. G and GL are application specific, contact Husky prior to machining. Click here for plunger / taper comparison.
Gate Detail (Taper)
23. 8 [0. 94] 14. 8 [0. 58] Int Pt 10. 010 +0. 005
A
METRIC IMPERIAL
110
0. 01 A
60
0. 8
R 0. 8 15MAX [0. 03]
GL
S
0. 4
0. 005 0. 0002
[0. 3941 + 0. 0002]
0. 0004 A
40 +0 -15'
0. 8
0. 80 [0. 03]
4. 1 [0. 162]
0. 8
R 0. 5 [0. 02]
Please confirm all dimensions and nozzle/gating suitability with Husky prior to machining.
7. 4 [0. 29]
R 0. 8 [0. 03]
8. 6 [0. 34] Int Pt
0. 4
G
3. 3 [0. 129]
1. 00 (0. 039"), 1. 20 (0. 047"), 1. 50 (0. 059") and 1. 80 (0. 071") (plunger) gates are standard, other sizes require customized parts. G and GL are application specific, contact Husky prior to machining.
46
2006. 08
Nozzle Selection
Plate Sizing - Pocket Detail
>10. 0 [0. 39] 40. 0 [1. 58]
< -
Ultra 500 VG-SX
60. 00 [2. 362] 0. 4 [0. 02]
2. 60 [0. 102]
20. 0 [0. 787]
8. 73 [0. 344]
+ 23. 000 - 0. 005 + [0. 9055 - 0. 0002]
R 12. 7 [0. 5] R 12. 7 [0. 5]
R 0. 8 [0. 03]
. 8
S
[. 03]
R 17. 0 [0. 67]
18. 00 [0. 709]
56. 0 [2. 21] 25. 01 + 0. 02 [0. 985 + 0. 001] 21. 0 [0. 83] R 3. 0 [0. 12]
S
J S K
BL 69. 15 - 149. 15 [2. 722 - 5. 872]
> 7. 0 [0. 3]
R 0. 4 [0. 02]
10. 00 [0. 394]
L 17. 0 - 123. 9 [ . 67 - 4. 88]
R 0. 8 [0. 03] 23. 8 [. 937]
For more than 16 drops. [. . . ] is variable according to gate diameter.
Gate Diameter > 1. 2mm (0. 047")
110
80
0. 8
[0. 004 + 0. 001]
V
0. 10 + 0. 03
S
0. 4
G
V
is application specific, contact Husky prior to machining. is variable according to gate diameter.
Please confirm all dimensions and nozzle/gating suitability with Husky prior to machining.
0.
G
4
58
2006. 08
Nozzle Selection
Plate Sizing - Pocket Detail
Ultra 500 HT-T
40. 00 [1. 574]
R 12. 7 [0. 5]
25. 01 + 0. 02 [0. 985 + 0. 001] 21. 0 [0. 83] 4. 8 x 15. 0 DP [0. 19 x 0. 59] 5. 03 + 0. 03 x 12. 0 DP [0. 198 + 0. 001 x . 47]
S
R 12. 7 [0. 5]
J K
> 7. 0 [0. 3]
R 3. 0 [0. 12] R 0. 40 [0. 02]
N
R 17. 0 [0. 67]
18. 00 [0. 709]
SL
For more than 16 drops. L-Dimensions > 113. 9mm (4. 48") / BL-Dimensions > 139. 2mm (5. 48") require 2 nozzle heaters. For bore geometry.
BL 69. 15 - 149. 15 [2. 722 - 5. 872]
Nominal dimensions shown for layout purpose only
Actual dimensions dependent on operating temperatures.
Thermal Calculations
BL / K / L / N / SL - Refer to the plate calculator at http://www. husky. ca/hotrunners/content-316-219. html - OR Contact Husky for plate thickness and critical bore depths. Ultra 500 HT-T Plate Sizing Number of Manifold Drops Height 2-4 6 - 16
L 17. 0 - 123. 9 [0. 67 - 4. 88]
R 0. 8 [0. 03] 23. 8 [. 937]
J
K
N
40. 00 (1. 574") 55. 1 (2. 17") 60. 00 (2. 362") 75. 1 (2. 96")
Contact Husky for more information
Please confirm all dimensions and nozzle/gating suitability with Husky prior to machining.
2006. 08
59
Ultra 500 HT-T
Gate Detail
Contact Husky with any gate insert backup concerns.
Nozzle Selection
Gate Diameter < 1. 2mm (0. 047")
23. 8 [0. 94] 14. 8 [0. 58] Int Pt 10. 010 + 0. 005
0. 01 A A 0. 005 METRIC 0. 0002 IMPERIAL
110
[0. 3941 +0. 0002]
0. 4
0. 0004 A
80
0. 8
60
0. 8
[0. 0002 + 0. 001]
V
8. 2 [0. 32] Int Pt
7. 0 [0. 28]
0. 8 [0. 03]
R 0. 8 [0. 03] R 0. 5 [0. 02]
0. 8
0. 05 + 0. 03
R 0. 8 15 MAX [0. 03]
S
0. 4
0. 4
G
G
V
is application specific, contact Husky prior to machining. is variable according to gate diameter.
Gate Diameter > 1. 2mm (0. 047")
110
80
0. 8
[0. 004 + 0. 001]
V
0. 10 + 0. 03
S
0. 4
G
V
is application specific, contact Husky prior to machining. is variable according to gate diameter.
Please confirm all dimensions and nozzle/gating suitability with Husky prior to machining.
0.
G
4
60
2006. 08
Nozzle Selection
Plate Sizing - Pocket Detail
Ultra 500 HT-U
40. 00 [1. 574]
R 12. 7 [0. 5]
25. 01 + 0. 02 [0. 985 + 0. 001] 21. 0 [0. 83]
R 12. 7 [0. 5]
J K
4. 8 x 15. 0 DP [0. 19 x 0. 59] 5. 03 + 0. 03 x 12. 0 DP [0. 198 + 0. 001 x 0. 47]
S
> 7. 0 [0. 3]
R 0. 4 [0. 02]
SL
R 3. 0 [0. 12]
N
R 17. 0 [0. 67]
18. 00 [0. 709]
For more than 16 drops. L-Dimensions > 113. 9mm (4. 48") / BL-Dimensions > 139. 2mm (5. 48") require 2 nozzle heaters. For bore geometry.
BL 69. 15 - 149. 15 [2. 722 - 5. 872]
L 17. 0 - 123. 9 [0. 67 - 4. 88]
R 0. 8 [0. 03] 23. 8 [. 937]
Nominal dimensions shown for layout purpose only
Actual dimensions dependent on operating temperatures.
Thermal Calculations
BL / K / L / N / SL - Refer to the plate calculator at http://www. husky. ca/hotrunners/content-316-219. html - OR Contact Husky for plate thickness and critical bore depths. Ultra 500 HT-U Plate Sizing Number of Manifold Drops Height 2-4 6 - 16
J
K
N
40. 00 (1. 574") 55. 1 (2. 17") 60. 00 (2. 362") 75. 1 (2. 96")
Contact Husky for more information
Please confirm all dimensions and nozzle/gating suitability with Husky prior to machining.
2006. 08
61
Ultra 500 HT-U
Gate Detail
Contact Husky with any gate insert backup concerns.
Nozzle Selection
Gate Diameter < 1. 2mm (0. 047")
23. 8 [0. 94] 14. 8 [0. 58] Int Pt 10. 010 + 0. 005
0. 01 A A 0. 005 METRIC 0. 0002 IMPERIAL
110
[0. 3941 +0. 0002]
0. 4
0. 0004 A
80
0. 8
60
0. 8
[0. 0002 + 0. 001]
V
8. 2 [0. 32] Int Pt
7. 0 [0. 28]
0. 8 [0. 03]
R 0. 8 [0. 03] R 0. 5 [0. 02]
0. 8
0. 05 + 0. 03
R 0. 8 15 MAX [0. 03]
S
0. 4
0. 4
G
G
V
is application specific, contact Husky prior to machining. is variable according to gate diameter.
Gate Diameter > 1. 2mm (0. 047")
110
80
0. 8
[0. 004 + 0. 001]
V
0. 10 + 0. 03
S
0. 4
G
V
is application specific, contact Husky prior to machining. is variable according to gate diameter.
Please confirm all dimensions and nozzle/gating suitability with Husky prior to machining.
0.
G
4
62
2006. 08
Nozzle Selection
Plate Sizing - Pocket Detail
Ultra 500 HT-DX
40. 00 [ 1. 574]
R 12. 7 [0. 5]
25. 01 + 0. 02 [0. 985 + 0. 001] 21. 0 [0. 83]
R 12. 7 [0. 5]
J K
4. 8 x 15. 0 DP [0. 19 x 0. 59] 5. 03 + 0. 03 x 12. 0 DP [0. 198 + 0. 001 x 0. 47]
S
BL 79. 15 - 159. 15 [3. 116 - 6. 265] > 7. 0 [0. 3]
R 0. 4 [0. 02]
SL
R 3. 0 [0. 12]
N
R 17. 0 [0. 67]
18. 00 [0. 709]
For more than 16 drops. L-Dimensions > 113. 9mm (4. 48") / BL-Dimensions > 139. 2mm (5. 48") require 2 nozzle heaters. For bore geometry.
Nominal dimensions shown for layout purpose only
Actual dimensions dependent on operating temperatures.
Thermal Calculations
BL / K / L / N / SL - Refer to the plate calculator at http://www. husky. ca/hotrunners/content-316-219. html - OR Contact Husky for plate thickness and critical bore depths. Ultra 500 HT-DX Plate Sizing Number of Manifold Drops Height 2-4 6 - 16
L 27. 0 - 133. 9 [1. 06 - 5. 27]
R 0. 8 [0. 03] 23. 8 [. 937]
J
K
N
40. 00 (1. 574") 55. 1 (2. 17") 60. 00 (2. 362") 75. 1 (2. 96")
Contact Husky for more information
Please confirm all dimensions and nozzle/gating suitability with Husky prior to machining.
2006. 08
63
Ultra 500 HT-DX
Gate Detail
Contact Husky with any gate insert backup concerns.
Nozzle Selection
23, 8 . 94 14, 8 . 58 10, 010 +0, 005 . 3941 +. 0002 Ra0. 4
Gate Diameter < 1. 2mm (0. 047")
110
60
0. 8
80
Ra
0. 8
30
R 0, 8 . 03
0, 50 . 020
R 0, 8 . 03 Ra0. 8
[0. 0002 + 0. 001]
10, 0 . 39 19, 6 . 77 INTSCT PT 17, 00 . 669
V
0. 05 + 0. 03
S
0. 4
0.
4
G
R 6, 0 . 24
Ra0. 8
G
V
is application specific, contact Husky prior to machining. is variable according to gate diameter.
Gate Diameter > 1. 2mm (0. 047")
110
80
0. 8
[0. 004 + 0. 001]
V
0. 10 + 0. 03
S
0. 4
G
V
is application specific, contact Husky prior to machining. is variable according to gate diameter.
Please confirm all dimensions and nozzle/gating suitability with Husky prior to machining.
0.
G
4
64
2006. 08
Nozzle Selection
Plate Sizing - Pocket Detail
Ultra 500 HT-DC
40. 00 [ 1. 574]
R 12. 7 [0. 5]
25. 01 + 0. 02 [0. 985 + 0. 001] 21. 0 [0. 83] 4. 8 x 15. 0 DP [0. 19 x 0. 59] 5. 03 + 0. 03 x 12. 0 DP [0. 198 + 0. 001 x 0. 47]
S
R 12. 7 [0. 5]
J K
R 17. 0 [0. 67]
18. 00 [0. 709]
R 3. 0 [0. 12] R 0. 4 [0. 02]
N SL
For more than 16 drops. L-Dimensions > 113. 9mm (4. 48") / BL-Dimensions > 139. 2mm (5. 48") require 2 nozzle heaters. For bore geometry.
BL 69. 15 - 149. 15 [2. 711 - 5. 872]
> 7. 0 [0. 3]
Nominal dimensions shown for layout purpose only
Actual dimensions dependent on operating temperatures.
Thermal Calculations
BL / K / L / N / SL - Refer to the plate calculator at http://www. husky. ca/hotrunners/content-316-219. html - OR Contact Husky for plate thickness and critical bore depths. Ultra 500 HT-DC Plate Sizing Number of Manifold Drops Height 2-4 6 - 16
L 17. 0 - 123. 9 [0. 67 - 4. 88]
R 0. 8 [0. 03] 23. 8 [. 937]
J
K
N
40. 00 (1. 574") 55. 1 (2. 17") 60. 00 (2. 362") 75. 1 (2. 96")
Contact Husky for more information
Please confirm all dimensions and nozzle/gating suitability with Husky prior to machining.
2006. 08
65
Ultra 500 HT-DC
Gate Detail
Contact Husky with any gate insert backup concerns.
Nozzle Selection
23. 8 [0. 94] 14. 00 [0. 551]
A
METRIC IMPERIAL
0. 005 0. 0002
60
R 0. 8 [0. 031]
6. 40 [0. 252] Int Pts
110
0. 8 0. 8
R 0. 5 [0. 02]
1. 50 [0. 059]
S
9. 005 + 0. 005
0. 01 A
[0. 3545 +0. 0002]
0. 0004 A
Please confirm all dimensions and nozzle/gating suitability with Husky prior to machining.
0. 4
R 0. 10 [+ 0. 10] [0. 004 +0. 004]
. 75 [. 030]
66
2006. 08
Nozzle Selection
Plate Sizing - Pocket Detail
Ultra 500 TS
40. 00 [ 1. 574]
R 12. 7 [0. 5]
25. 01 + 0. 02 [0. 985 + 0. 001] 21. 0 [0. 83] 4. 8 x 15. 0 DP [0. 19 x 0. 59] 5. 03 + 0. 03 x 12. 0 DP [0. 198 + 0. 001 x 0. 47]
S
R 12. 7 [0. 5]
J K
> 7. 0 [0. 3]
R 0. 4 [0. 02]
SL
R 3. 0 [0. 12]
N
R 17. 0 [0. 67]
18. 00 [0. 709]
For more than 16 drops. [. . . ] Actual BL dimension is based on application specific parameters supplied to Husky prior to design. Husky provides all manufacturing dimensions with customer drawings. Maximum operating temperature is 375°C (710° F). Maximum operating injection pressure is 1793 bar (26000 psi) Taper or plunger style stem available. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HUSKY HRDC-U500-061117
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.