Detailed instructions for use are in the User's Guide.
[. . . ] Key features include: · · · · · · · · · 2, 4, and 8 Drop configurations Infinitely flexible nozzle spacing within upper and lower limits Three nozzle sizes (Ultra 500, Ultra 750, and Ultra 1000) Sixteen different gating styles including valve gate and thermal gate options Every application is reviewed and channel sizes are optimized for the application Suitable for a wide range of resins including engineering and filled resins Used in a broad variety of markets including housewares, closures, electronics, automotive, medical and more Lower cost than custom systems Faster delivery than custom systems
This brochure provides information needed to do a preliminary layout of a mold using a Pronto manifold system. For information about Pronto complete hot runner systems, including plate drawings and standard feature locations please visit our web site www. hotrunners. com.
Pronto manifold systems come complete with heated sprue bushing, nozzles, all necessary heaters and thermocouples, associated hardware, and wire clamps. Locating ring and electrical connectors are available upon request. [. . . ] However, these values cannot be combined otherwise interference will result (i. e. To verify that your pitch is acceptable, refer to the table below and solve for X & Y using the following calculation: U500VG / U750VG / U750HT X + 1. 47Y - 83. 7 >= 0 U500HT X + 1. 47Y - 65. 3 >= 0 If X and Y both satisfy the equation, then the pitch and sprue offset values can be incorporated into Pronto 2T.
PRONTO 4 Drop H-Type Manifolds
Nozzle 500/750 1000 500/750 1000 Minimum Pitch (X) 50mm (1. 969") 53mm (2. 087") Minimum Pitch (Y) 50mm (1. 969") 53mm (2. 087") Maximum Pitch (X) 211mm (8. 307") 362mm (14. 252") Maximum Pitch (Y) 331mm (13. 031") 200mm (7. 874") Number of T/C's 1 or 2 T/C Mounted Through Manifold/Backing Plate (If Req'd) Electrical Zones
Y
6 or 7
X
PRONTO 4 Drop N-Type Manifolds
Nozzle Min Pitch (X1/X2/X3/X4) Max Pitch (X1X2/X3/X4) 1000 53mm (2. 087") Min Pitch (Y1/Y2) 53mm (2. 087") 362mm (14. 252") Max Pitch (Y1/Y2) 200mm (7. 874") Number of T/C's 1 or 2 T/C's Mounted Through Manifold/Backing Plate (If Req'd) Electrical Zones
X1 X2
Y1
6 or 7
Y2
1000
X3
X4
Please confirm all dimensions and nozzle suitability by contacting Husky.
5
2003. 11
PRONTO
PRONTO 4 Drop A-Type Manifolds
Nozzle Minimum Pitch (X) Maximum Pitch (X) Number of T/C's 1 T/C Mounted Through Manifold Plate Electrical Zones 6
X
500/750
50mm (1. 969")
180mm (7. 087")
X
PRONTO 4 Drop L-Type Manifolds
Nozzle 500/750 Minimum Pitch (X) Maximum Pitch (X) Number of T/C's Electrical Zones
Y
HT/TS 60mm (2. 363") HT/TS 316mm (12. 441") VG/VX 70mm (2. 756") VG/VX 304mm (11. 969") 1 T/C Mounted Minimum Pitch (Y) Maximum Pitch (Y) Through Manifold Plate HT/TS 105mm (4. 134") 500/750 361mm (14. 212") VG/VX 127mm (5. 000")
6
X
NOTE: For HT/TS Y-dimension must be 45mm (1. 772") greater than X-dimension NOTE: For VG/VX Y-dimension must be 57mm (2. 244") greater than X-dimension
PRONTO 8 Drop H-Type Manifolds
Nozzle HT 500 Min X 73mm (0. 708") 73mm (0. 886") Max X Min Y1 211mm 61. 3mm (8. 307") (1. 752") 211mm 61. 3mm (8. 307") (1. 693") Max Y1 Min Y2 Max Y2 Number of Electrical T/C's Zones
X
Y2-62mm Y1+62mm 331mm 2 T/C Mounted (1. 000") (1. 000") (13. 031") Through Man Plate Y2-62mm Y1+62mm 331mm HT 750 2 T/C Mounted 11 or 13 (1. 771") (1. 771") (13. 031") Through Back 73mm 211mm 61. 3mm Y2-62mm Y1+62mm 331mm Plate (when VG 500/750 (0. 984") (8. 307") (2. 165") (1. 968") (1. 968") (13. 031") required)
Y2 Y1
Please confirm all dimensions and nozzle suitability by contacting Husky. 2003. 11
6
1 Drop
PRONTO 1 Drop I-Type Manifolds (Ultra 1000 Only)
X + 28, 0 [1. 10] X + 29, 00 [1. 142] X + 15, 2 [0. 60] X + 45, 0 [1. 77]
PRONTO
0, 000 [. 0000]
113, 0 [4. 45]
35, 0 [1. 38]
35, 0 [1. 38]
RAD 35, 0 [1. 38]
40, 0 [1. 57] 28, 0 [1. 10]
0, 000 [. 0000] 15, 2 [0. 60] 28, 0 [1. 10] 29, 0 [1. 14] 40, 0 [1. 57] R 27, 0 [1. 06] (4)
X
RAD 27, 5 [1. 08]
View From Injection Side
Plate features are noted on plan view and correspond to features in section view below.
For HT / TS For HT / TS
26. 8 [1. 06]
40. 0 [1. 57]
12. 5 [0. 49]
3. 0 MIN [. 12]
8. 000 +0. 015 [. 3150 +. 0006]
*C
1/4 -20
M6
(2)
*B
80. 8 [3. 18]
BK-PLT
*B
6. 8 [. 27] MF-PLT 6. 8 x 17. 0 DP. 42. 0 [1. 66] [ . 32 +. 0001 x . 59 DP. ] 60. 01 +0. 03 [2. 36 +. 0001] 30. 0 MAX 1. 5R [1. 18] [. 06] 44. 01 +0. 03 [1. 733 +. 001] R 1. 5 [. 06] MAX 22. 2 [. 88] T/C MF-PLT THRU HOLE FOR X> 87 mm 22. 2 [. 88] T/C MF-PLT
Minimum Pitch (X) Maximum Pitch (X) HT/TS 55mm (2. 165") VG/VX 74mm (2. 913")
Number of T/C's
Electrical T/C : Thermocouple Zones BK - PLT : Manifold Backing Plate
MF - PLT : Manifold Plate X : Pitch X Value
695mm (27. 362")
1 T/C Mounted Through Manifold Plate
3
Y : Pitch Y Value R, RAD : Radius C : Center Insulator Bore Depth* B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com
Please confirm all dimensions and nozzle suitability by contacting Husky.
7
2003. 11
92. 6 [3. 65]
RAD 3. 0 [. 12]
75. 0 [2. 95]
79. 0 [3. 11]
70. 00 [2. 76] 60. 00 [2. 36]
68. 00 [2. 68]
60. 00 [2. 36]
M16 [5/8-11 UNC] (3 Bolts per drop recommeded)
For VG / VX
PRONTO
PRONTO 2 Drop A-Type Manifolds (Ultra 1000)
X - 52, 2 [X - 2 . 06] IF X<100, 0 [3. 94] T/C IS SIDE MOUNTED
2 Drop
X + 41, 00 [1. 614]
X + 25, 0 [. 98]
0, 000 [. 0000]
35, 0 [1. 38]
32, 0 [1. 26]
32, 0 [1. 26]
35, 0 [1. 38]
X
100, 0 [3. 94]
RAD 5, 0 [. 20] (2) RAD 35, 0 [1. 38]
60, 0 [2. 36] 40, 0 [1. 58] 28, 0 [1. 10] RAD 27, 5 [1. 08] 0, 000 [0. 0000]
28, 0 [1. 10] 40, 0 [1. 58]
View From Injection Side
RAD 27, 0 (5) [1. 06]
Plate features are noted on plan view and correspond to features in section view below.
For HT / TS For HT / TS
X + 45, 0 [1. 77]
26. 8 [1. 06]
40. 0 [1. 57]
12. 5 [0. 49]
3. 0 MIN [. 12]
8. 000 +0. 015 [. 3150 +. 0006]
*C
1/4 -20
M6
(2)
*B
80. 8 [3. 18]
BK-PLT
*B
6. 8 [. 27] MF-PLT 6. 8 x 17. 0 DP. Plate features are noted on plan view and correspond to features in section view below.
For HT / TS For VG /VX
M12 [1/2-13 UNC] (3 Bolts per drop recommeded)
For HT / TS For VG /VX
MAX
MIN
Sharp
THRU HOLE FOR X > 87 mm
T/C : Thermocouple BK - PLT : Manifold Backing Plate
Minimum Pitch (X) Maximum Pitch (X) HT/TS 60mm (2. 363") VG/VX 70mm (2. 756")
Number of T/C's
Electrical Zones
MF - PLT : Manifold Plate X : Pitch X Value Y : Pitch Y Value R, RAD : Radius
366mm (14. 409")
1 T/C Mounted Through Manifold Plate
4
C : Center Insulator Bore Depth* B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com
Please confirm all dimensions and nozzle suitability by contacting Husky. 2003. 11
10
For VG /VX
2 Drop
PRONTO 2 Drop T-Type Manifold Type I (Ultra 1000)
X + 41, 00 [1. 614] X + 21, 5 [. 85] X + 28, 0 [1. 10] 24, 0 [0. 95] 31. 45 [1. 238] 24, 0 [0. 95] 0, 000 [. 0000] 30, 0 [1. 18] 61, 0 [2. 40] X
PRONTO
47, 0 [1. 85] 41, 0 [1. 61] 30, 0 [1. 18]
0, 000 [. 0000] 14, 0 [0. 55]
RAD 27, 5 [1. 08] RAD 35, 0 [1. 38]
R 10, 0 (2) [0. 39]
Contact Husky for T/C Location
51, 0 [2. 01]
Y Y + 39, 32 [1. 548]
View From Injection Side
Y + 130, 0 [5. 12] R 27, 0 (6) [1. 06]
Contact Husky to verfiy T/C thru hole location. Plate features are noted on plan view and correspond to features in section view below.
For HT / TS For HT / TS
M16 [5/8-11 UNC] (3 Bolts per drop recommeded)
68. 00 [2. 68]
For VG / VX
60. 00 [2. 36] 79. 0 [3. 11]
40. 0 [1. 57]
12. 5 [0. 49]
3. 0 MIN [. 12]
8. 000 +0. 015 [. 3150 +. 0006]
*C
1/4 -20
M6
(2)
*B
80. 8 [3. 18]
BK-PLT
*B
6. 8 [. 27] MF-PLT 6. 8 x 17. 0 DP. 42. 0 [1. 66] [ . 32 +. 0001 x . 59 DP. ] 60. 01 +0. 03 [2. 36 +. 0001] 30. 0 MAX 1. 5R [1. 18] [. 06] 44. 01 +0. 03 [1. 733 +. 001] R 1. 5 [. 06] MAX 22. 2 [. 88] T/C MF-PLT THRU HOLE FOR X> 87 mm 22. 2 [. 88] T/C MF-PLT
T/C : Thermocouple
Minimum Pitch (X) 53mm (2. 087") Minimum Pitch (Y) 53mm (2. 087")
Maximum Pitch (X) 362mm (14. 252") Maximum Pitch (Y) 200mm (7. 874")
Number of T/C's 1 or 2 T/C Mounted Through Manifold Plate
Electrical Zones 4 or 5
BK - PLT : Manifold Backing Plate MF - PLT : Manifold Plate X : Pitch X Value Y : Pitch Y Value R, RAD : Radius C : Center Insulator Bore Depth* B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com
Please confirm all dimensions and nozzle suitability by contacting Husky.
11
2003. 11
92. 6 [3. 65]
RAD 3. 0 [. 12]
75. 0 [2. 95]
70. 00 [2. 76]
60. 00 [2. 36]
26. 8 [1. 06]
PRONTO
PRONTO 2 Drop T-Type Manifold Type I (Ultra 750)
X + 15, 0 [0. 591] - 24, 00 [- 0. 945] 0, 000 [0. 000] 22, 65 [0. 892] 24, 0 [0. 94] 26, 000 [1. 0236] 61, 1 [2. 41] (2) 66, 0 [2. 60] - 56, 0 [- 2. 20] -100, 0 [3. 94]
2 Drop
X
RAD 22, 0 [0. 87] (2)
Y + 55, 0 [+ 2. 165] Y + 38, 0 [+ 1. 496] Y + 33, 72 [+ 1. 328] Y + 25, 5 [+ 1. 004] Y + 23, 0 [+ 0. 906] Y + 6, 0 [+ 0. 236] Y Y - 6, 0 [- 0. 236]
TOP
Y - 38, 0 [- 1. 496] Y - 48, 0 [- 1. 890] RAD 5, 0 [0. 20] (2) RAD 15, 0 [0. 59]
Recommeded drop bolt circle
Min > 10, 0 [0. 394]
R 55, 0 [2. 17]
0, 000 [0. 0000] - 1, 0 [- 0. 04] - 31, 65 [- 1. 246] - 33, 0 [- 1. 30]
View From Injection Side
RAD 27, 0 [1. 06] (8)
OPERATOR
Contact Husky to verify T/C thru hole location. Plate features are noted on plan view and correspond to features in section view below.
For HT / TS For VG /VX For HT / TS
For HT / TS For VG /VX
M16 [5/8-11 UNC] (3 Bolts per drop recommeded)
MAX
MIN
MAX
T THRU HOLE FOR X>87 mm
T/C : Thermocouple
Minimum Pitch (X1/X2) HT 500 12. 7mm (0. 500") HT/TS 750 22. 5mm (0. 886") VG 500/750 25. 0mm (0. 984") Minimum Pitch (Y) HT 500 25. 4mm (1. 000") HT/TS 750 25. 4mm (1. 000") VG 500/750 25. 4mm (1. 000")
2003. 11
Maximum Pitch (X1/X2)
Number Electrical BK - PLT : Manifold Backing Plate of T/C's Zones MF - PLT : Manifold Plate
X : Pitch X Value Y : Pitch Y Value R, RAD : Radius
HT 500 350. 0mm (13. 780") HT/TS 750 350. 0mm (13. 780") 1 or 2 T/C VG 500/750 350. 0mm (13. 780") Mounted Maximum Pitch (Y) Through Manifold HT 500 200. 0mm (7. 874") Plate HT/TS 750 200. 0mm (7. 874") VG 500/750 200. 0mm (7. 874")
4 or 5
C : Center Insulator Bore Depth* B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com
Please confirm all dimensions and nozzle suitability by contacting Husky.
12
For VG /VX
2 Drop
PRONTO 2 Drop T-Type Manifold Type I (Ultra 500)
X + 15, 0 [0. 591] - 24, 00 [- 0. 945] 0, 000 [0. 000] 22, 65 [0. 892] 24, 0 [0. 94] 26, 000 [1. 0236] 61, 1 [2. 41] (2) 66, 0 [2. 60] - 56, 0 [- 2. 20] -100, 0 [3. 94]
PRONTO
X
RAD 22, 0 [0. 87] (2)
Y + 55, 0 [+ 2. 165] Y + 38, 0 [+ 1. 496] Y + 33, 72 [+ 1. 328] Y + 18, 0 [+ 0. 17] (2) Y + 23, 0 [+ 0. 906] Y + 6, 0 [+ 0. 236] Y Y - 6, 0 [- 0. 236]
Y - 38, 0 [- 1. 496] Y - 48, 0 [- 1. 890] RAD 5, 0 [0. 20] (2) RAD 15, 0 [0. 59]
TOP
R 55, 0 [2. 17]
Recommeded drop bolt circle
Min > 10, 0 [0. 394]
0, 000 [0. 0000] - 1, 0 [- 0. 04] - 31, 65 [- 1. 246] - 33, 0 [- 1. 30]
RAD 27, 0 [1. 06] (8)
View From Injection Side
OPERATOR
Contact Husky to verfiy T/C thru hole location. Plate features are noted on plan view and correspond to features in section view below.
For HT / TS For VG /VX
For HT / TS For VG /VX
M12 [1/2-13 UNC] (3 Bolts per drop recommeded)
MAX
MIN
Sharp
THRU HOLE FOR X > 87 mm
T/C : Thermocouple
Minimum Pitch (X1/X2) HT 500 12. 7mm (0. 500") HT/TS 750 22. 5mm (0. 886") VG 500/750 25. 0mm (0. 984") Minimum Pitch (Y) HT 500 25. 4mm (1. 000") HT/TS 750 25. 4mm (1. 000") VG 500/750 25. 4mm (1. 000")
Maximum Pitch (X1/X2)
Number of Electrical T/C's Zones
BK - PLT : Manifold Backing Plate MF - PLT : Manifold Plate X : Pitch X Value Y : Pitch Y Value R, RAD : Radius
HT 500 350. 0mm (13. 780") HT/TS 750 350. 0mm (13. 780") 1 or 2 T/C VG 500/750 350. 0mm (13. 780") Mounted Maximum Pitch (Y) Through Manifold HT 500 200. 0mm (7. 874") Plate HT/TS 750 200. 0mm (7. 874") VG 500/750 200. 0mm (7. 874")
4 or 5
C : Center Insulator Bore Depth* B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com
Please confirm all dimensions and nozzle suitability by contacting Husky.
For VG /VX
13
2003. 11
PRONTO
PRONTO 2 Drop T-Type Manifold Type II (Ultra 750)
RAD 27, 0 [1. 06] (8)
2 Drop
+ 33, 0 [+ 1. 30] + 31, 65 [+ 1. 246] + 1, 0 [+ 0. 04] 0, 000 [0. 0000]
Min > 10, 0 [0. 394] R 55, 0 [2. 17]
TOP
Recommeded drop bolt circle
RAD 5, 0 [0. 20] (2) Y + 48, 0 [+ 1. 890] Y + 38, 0 [+ 1. 496] RAD 15, 0 [0. 59]
Y + 6, 0 [+ 0. 236] Y Y - 6, 0 [- 0. 236] Y - 23, 0 [- 0. 906] Y - 25, 5 [- 1. 004] Y - 33, 72 [- 1. 328] Y - 38, 0 [- 1. 496] Y - 55, 0 [- 2. 165]
RAD 22, 0 [0. 87] (2)
X + 15, 0 [0. 591]
-100, 0 [- 3. 94]
View From Injection Side
OPERATOR
Contact Husky to verfiy T/C thru hole location. Plate features are noted on plan view and correspond to features in section view below.
For HT / TS For VG /VX For HT / TS
- 24, 00 [- 0. 945]
0, 000 [0. 000] 22, 65 [0. 892] 24, 0 [0. 94] 26, 000 [1. 0236]
61, 1 [2. 41] (2) 66, 0 [2. 60]
- 56, 0 [- 2. 20]
X
For HT / TS For VG /VX
M16 [5/8-11 UNC] (3 Bolts per drop recommeded)
MAX
MIN
MAX
T THRU HOLE FOR X>87 mm
Minimum Pitch (X1/X2)
Maximum Pitch (X1/X2)
Number of T/C's
Electrical Zones
T/C : Thermocouple BK - PLT : Manifold Backing Plate MF - PLT : Manifold Plate X : Pitch X Value Y : Pitch Y Value R, RAD : Radius
HT 500 350. 0mm (13. 780") HT 500 12. 7mm (0. 500") HT/TS 750 350. 0mm (13. 780") HT/TS 750 22. 5mm (0. 886") 1 or 2 T/C VG 500/750 350. 0mm VG 500/750 25. 0mm (0. 984") Mounted (13. 780") Through Minimum Pitch (Y) Maximum Pitch (Y) Manifold HT 500 25. 4mm (1. 000") HT 500 200. 0mm (7. 874") Plate HT/TS 750 25. 4mm (1. 000") HT/TS 750 200. 0mm (7. 874") VG 500/750 25. 4mm (1. 000") VG 500/750 200. 0mm (7. 874")
2003. 11
4 or 5
C : Center Insulator Bore Depth* B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com
Please confirm all dimensions and nozzle suitability by contacting Husky.
14
For VG /VX
2 Drop
PRONTO 2 Drop T-Type Manifold Type II (Ultra 500)
RAD 27, 0 [1. 06] (8)
PRONTO
+ 33, 0 [+ 1. 30] + 31, 65 [+ 1. 246] + 1, 0 [+ 0. 04] 0, 000 [0. 0000]
Min > 10, 0 [0. 394] R 55, 0 [2. 17]
Recommeded drop bolt circle TOP
RAD 5, 0 [0. 20] (2) Y + 48, 0 [+ 1. 890] Y + 38, 0 [+ 1. 496] Y + 18, 0 [+ 0. 17] Y + 6, 0 [+ 0. 236] Y Y - 6, 0 [- 0. 236] Y - 23, 0 [- 0. 906] Y - 33, 72 [- 1. 328] Y - 38, 0 [- 1. 496] Y - 55, 0 [- 2. 165] RAD 15, 0 [0. 59]
RAD 22, 0 [0. 87] (2)
X + 15, 0 [0. 591]
-100, 0 [- 3. 94]
View From Injection Side
OPERATOR
Plate features are noted on plan view and correspond to features in section view below.
For HT / TS For VG /VX
- 24, 00 [- 0. 945]
0, 000 [0. 000] 22, 65 [0. 892] 24, 0 [0. 94] 26, 000 [1. 0236]
61, 1 [2. 41] (2) 66, 0 [2. 60]
- 56, 0 [- 2. 20]
X
M12 [1/2-13 UNC] (3 Bolts per drop recommeded)
MAX
MIN
Sharp
THRU HOLE FOR X > 87 mm
Minimum Pitch (X1/X2)
Maximum Pitch (X1/X2)
Number of T/C's
Electrical Zones
T/C : Thermocouple BK - PLT : Manifold Backing Plate MF - PLT : Manifold Plate X : Pitch X Value Y : Pitch Y Value R, RAD : Radius C : Center Insulator Bore Depth* B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com
HT 500 12. 7mm (0. 500") HT 500 350. 0mm (13. 780") HT/TS 750 22. 5mm (0. 886") HT/TS 750 350. 0mm (13. 780") 1 or 2 T/C VG 500/750 25. 0mm (0. 984") VG 500/750 350. 0mm (13. 780") Mounted Minimum Pitch (Y) Maximum Pitch (Y) Through Manifold HT 500 25. 4mm (1. 000") HT 500 200. 0mm (7. 874") Plate HT/TS 750 25. 4mm (1. 000") HT/TS 750 200. 0mm (7. 874") VG 500/750 25. 4mm (1. 000") VG 500/750 200. 0mm (7. 874")
4 or 5
Please confirm all dimensions and nozzle suitability by contacting Husky.
For VG /VX
15
2003. 11
PRONTO
PRONTO 2 Drop T-Type Manifold Type III (Ultra 750)
TOP
- 24, 00 [- 0. 945] (2) 22, 65 [0. 892] 26, 000 [1. 0236] 32, 0 [1. 26] (2) X + 15, 0 [0. 59] 53, 2 [2. 10] (2) 61, 0 [2. 40] (2) 0, 000 [0. 000]
2 Drop
Y + 93, 0 [3. 66]
X
RAD 5, 000 [0. 1969] (4) Y + 59, 2 [2. 33] Y + 38, 0 [1. 50] (2) Y + 33, 72 [1. 328] Y + 25, 50 [1. 004]
OPERATOR
Y + 6, 0 [0. 24] Y Y - 6, 0 [0. 24]
Y - 43, 0 [1. 69]
R 55, 0 [2. 17]
RAD 10, 000 [0. 3937] (2)
Recommeded drop bolt circle
0, 000 [0. 000]
View From Injection Side
-31. 65 [-1. 246] - 33, 0 [-1. 30] (2)
RAD 27, 0 [1. 0630] (7)
Plate features are noted on plan view and correspond to features in section view below.
For HT / TS For VG /VX For HT / TS
For HT / TS
For VG /VX
M16 [5/8-11 UNC] (3 Bolts per drop recommeded)
MAX
MIN
MAX
T THRU HOLE FOR X>87 mm
Minimum Pitch (X1/X2) HT 500 12. 7mm (0. 500") HT/TS 750 22. 5mm (0. 886") VG 500/750 25. 0mm (0. 984") Minimum Pitch (Y) HT 500 25. 4mm (1. 000") HT/TS 750 25. 4mm (1. 000") VG 500/750 25. 4mm (1. 000")
Maximum Pitch (X1/X2) HT 500 350. 0mm (13. 780") HT/TS 750 350. 0mm (13. 780") VG 500/750 350. 0mm (13. 780") Maximum Pitch (Y) HT 500 200. 0mm (7. 874") HT/TS 750 200. 0mm (7. 874") VG 500/750 200. 0mm (7. 874")
Number of Electrical T/C's Zones 1 or 2 T/C Mounted Through Manifold Plate
T/C : Thermocouple BK - PLT : Manifold Backing Plate MF - PLT : Manifold Plate X : Pitch X Value Y : Pitch Y Value R, RAD : Radius
4 or 5
C : Center Insulator Bore Depth* B : Nozzle Bore Depth* *Refer to calculator on www. hotrun-
Please confirm all dimensions and nozzle suitability by contacting Husky. 2003. 11
16
For VG /VX
2 Drop
PRONTO 2 Drop T-Type Manifold Type III (Ultra 500)
TOP
- 24, 00 [- 0. 945] (2) 22, 65 [0. 892] 26, 000 [1. 0236] 32, 0 [1. 26] (2) X + 15, 0 [0. 59] 53, 2 [2. 10] (2) 61, 0 [2. 40] (2) 0, 000 [0. 000]
PRONTO
Y + 93, 0 [3. 66]
X
RAD 5, 000 [0. 1969] (4) Y + 59, 2 [2. 33] Y + 38, 0 [1. 50] (2) Y + 33, 72 [1. 328]
OPERATOR
Y + 18, 0 [+ 0. 17] Y + 6, 0 [0. 24] Y Y - 6, 0 [0. 24]
Y - 43, 0 [1. 69]
R 55, 0 [2. 17]
RAD 10, 000 [0. 3937] (2)
Recommeded drop bolt circle
0, 000 [0. 000]
View From Injection Side
-31. 65 [-1. 246] - 33, 0 [-1. 30] (2)
RAD 27, 0 [1. 0630] (7)
Plate features are noted on plan view and correspond to features in section view below.
For HT / TS For VG /VX
M12 [1/2-13 UNC] (3 Bolts per drop recommeded)
MAX
MIN
Sharp
THRU HOLE FOR X > 87 mm
Minimum Pitch (X1/X2)
Maximum Pitch (X1/X2)
Number of Electrical T/C's Zones
T/C : Thermocouple BK - PLT : Manifold Backing Plate MF - PLT : Manifold Plate X : Pitch X Value Y : Pitch Y Value R, RAD : Radius
HT 500 12. 7mm (0. 500") HT 500 350. 0mm (13. 780") HT/TS 750 22. 5mm (0. 886") HT/TS 750 350. 0mm (13. 780") 1 or 2 T/C VG 500/750 25. 0mm (0. 984") VG 500/750 350. 0mm (13. 780") Mounted Minimum Pitch (Y) Maximum Pitch (Y) Through Manifold HT 500 25. 4mm (1. 000") HT 500 200. 0mm (7. 874") Plate HT/TS 750 25. 4mm (1. 000") HT/TS 750 200. 0mm (7. 874") VG 500/750 25. 4mm (1. 000") VG 500/750 200. 0mm (7. 874")
4 or 5
C : Center Insulator Bore Depth* B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com
Please confirm all dimensions and nozzle suitability by contacting Husky.
For VG /VX
17
2003. 11
PRONTO
PRONTO 4 Drop H-Type Manifolds (Ultra 1000)
X + 41, 00 [1. 614] X + 28, 0 [1. 10] X + 21, 5 [. 85] X + 39, 7 [1. 56] X + 21, 0 [0. 83] X + 21, 0 [1. 06] 0, 000 [. 0000]
4 Drop
X
56, 7 [2. 23]
RAD 27, 0 (6) [1. 06]
Y1 + 100, 0 [3. 94] RAD 12, 7 (6) [1. 06] RAD 35, 0 Y1 + 61, 7 [2. 43] Contact Husky for T/C Location Y1 + 22, 0 [0. 87] Y1 Y1 - 13, 0 [0. 51] Y1 - 17, 7 [0. 70] Y1 - 52, 7 [2. 07] [1. 38]
RAD 27, 5 [1. 08]
0, 000 [. 0000]
Y2 - 52, 7 [2. 07] Y2 - 17, 7 [0. 70] Y2 - 13, 0 [0. 51] Y2
View From Injection Side
Y2 + 22, 0 [0. 87]
Plate features are noted on plan view and correspond to features in section view below.
For HT / TS For HT / TS
26. 8 [1. 06]
40. 0 [1. 57]
12. 5 [0. 49]
3. 0 MIN [. 12]
8. 000 +0. 015 [. 3150 +. 0006]
*C
1/4 -20
M6
(2)
*B
80. 8 [3. 18]
BK-PLT
*B
6. 8 [. 27] MF-PLT 6. 8 x 17. 0 DP. 42. 0 [1. 66] [ . 32 +. 0001 x . 59 DP. ] 60. 01 +0. 03 [2. 36 +. 0001] 30. 0 MAX 1. 5R [1. 18] [. 06] 44. 01 +0. 03 [1. 733 +. 001] R 1. 5 [. 06] MAX 22. 2 [. 88] T/C MF-PLT THRU HOLE FOR X> 87 mm 22. 2 [. 88] T/C MF-PLT
T/C : Thermocouple BK - PLT : Manifold Backing Plate
Minimum Pitch (X) Maximum Pitch (X)
Number of T/C's
Electrical Zones 6 or 7
MF - PLT : Manifold Plate X : Pitch X Value Y : Pitch Y Value R, RAD : Radius C : Center Insulator Bore Depth* B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com
53mm (2. 087") 362mm (14. 252") 1 T/C Mounted thru MF PLT Minimum Pitch (Y) Maximum Pitch (Y) 1 T/C Mounted Thru BK PLT (when required) 53mm (2. 087") 200mm (7. 874")
Please confirm all dimensions and nozzle suitability by contacting Husky. 2003. 11
18
92. 6 [3. 65]
RAD 3. 0 [. 12]
75. 0 [2. 95]
79. 0 [3. 11]
70. 00 [2. 76]
60. 00 [2. 36]
68. 00 [2. 68]
60. 00 [2. 36]
M16 [5/8-11 UNC] (4 Bolts per drop recommended)
For VG / VX For VG / VX
4 Drop
PRONTO 4 Drop H-Type Manifolds (Ultra 750)
PRONTO
Manifold Heater #1A (Clamp) #1B (Injection)
Recommeded drop bolt circle
View From Injection Side
Plate features are noted on plan view and correspond to features in section view below.
For HT / TS For VG /VX For HT / TS
For HT / TS
For VG /VX
M16 [5/8-11 UNC] (3 Bolts per drop recommeded)
MAX
MIN
MAX
T THRU HOLE FOR X>87 mm
T/C : Thermocouple BK - PLT : Manifold Backing Plate MF - PLT : Manifold Plate X : Pitch X Value Y : Pitch Y Value R, RAD : Radius C : Center Insulator Bore Depth*
Minimum Pitch (X) HT/TS 50mm (1. 969") VG/VX 50mm (1. 969") Minimum Pitch (Y) HT/TS 50mm (1. 969") VG/VX 50mm (1. 969")
Maximum Pitch (X)
Number of T/C's
Electrical Zones
HT/TS 211mm (8. 307") 1 T/C Mounted VG/VX 211mm (8. 307") Through MF PLT Maximum Pitch (Y) 1 T/C Mounted Through BK PLT 331mm (13. 031") (when required)
6 or 7
B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com
Please confirm all dimensions and nozzle suitability by contacting Husky.
19
For VG /VX
2003. 11
PRONTO
PRONTO 4 Drop H-Type Manifolds (Ultra 500)
4 Drop
Manifold Heater #1A (Clamp) #1B (Injection)
Recommeded drop bolt circle
View From Injection Side
Plate features are noted on plan view and correspond to features in section view below.
For HT / TS For VG /VX
M12 [1/2-13 UNC] (3 Bolts per drop recommeded)
MAX
MIN
Sharp
THRU HOLE FOR X > 87 mm
T/C : Thermocouple BK - PLT : Manifold Backing Plate MF - PLT : Manifold Plate X : Pitch X Value Y : Pitch Y Value R, RAD : Radius C : Center Insulator Bore Depth*
Minimum Pitch (X) HT/TS 50mm (1. 969") VG/VX 50mm (1. 969") Minimum Pitch (Y) HT/TS 50mm (1. 969") VG/VX 50mm (1. 969")
2003. 11
Maximum Pitch (X)
Number of T/C's
Electrical Zones
HT/TS 211mm (8. 307") 1 T/C Mounted VG/VX 211mm (8. 307") Through MF PLT Maximum Pitch (Y) 1 T/C Mounted Through BK PLT 331mm (13. 031") (when required)
6 or 7
B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com
Please confirm all dimensions and nozzle suitability by contacting Husky.
20
For VG /VX
4 Drop
PRONTO 4 Drop A-Type Manifolds (Ultra 750)
PRONTO
T/C
Manifold Heater #1A (Clamp) #1B (Injection)
View From Injection Side
Recommeded drop bolt circle
For HT / TS For VG /VX For HT / TS
M16 [5/8-11 UNC] (3 Bolts per drop recommeded)
For HT / TS For VG /VX
MAX
MIN
MAX
T THRU HOLE FOR X>87 mm
T/C : Thermocouple BK - PLT : Manifold Backing Plate MF - PLT : Manifold Plate X : Pitch X Value Y : Pitch Y Value R, RAD : Radius C : Center Insulator Bore Depth* B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com Please confirm all dimensions and nozzle suitability by contacting Husky.
Minimum Pitch (X) Maximum Pitch (X) 50mm (1. 969") 180mm (7. 087")
Number of T/C's 1 T/C Mounted Through Manifold Plate
Electrical Zones 6
For VG /VX
21
2003. 11
PRONTO
PRONTO 4 Drop A-Type Manifolds (Ultra 500)
4 Drop
T/C
Manifold Heater #1A (Clamp) #1B (Injection)
View From Injection Side
Recommeded drop bolt circle
For HT / TS For VG /VX
M12 [1/2-13 UNC] (3 Bolts per drop recommeded)
MAX
MIN
Sharp
THRU HOLE FOR X > 87 mm
T/C : Thermocouple
Minimum Pitch (X) Maximum Pitch (X) 50mm (1. 969") 180mm (7. 087")
Number of T/C's 1 T/C Mounted Through Manifold Plate
Electrical Zones 6
BK - PLT : Manifold Backing Plate MF - PLT : Manifold Plate X : Pitch X Value Y : Pitch Y Value R, RAD : Radius C : Center Insulator Bore Depth* B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com
Please confirm all dimensions and nozzle suitability by contacting Husky. 2003. 11
22
For VG /VX
4 Drop
PRONTO 4 Drop N-Type Manifolds (Ultra 1000)
X1 + 41, 00 [1. 614] X1 + 28, 0 [1. 10] X1 + 21, 5 [. 85] - 56, 7 [2. 23] - 39, 7 [1. 56] - 21, 0 [0. 83] 0, 000 [. 0000]
PRONTO
X1
21, 0 [1. 06]
RAD 27, 0 (6) [1. 06] Y1 + 100, 0 [3. 94] RAD 12, 7 (6) [1. 06] Y1 + 61, 7 [2. 43] RAD 35, 0 [1. 38]
Contact Husky for T/C location
Y1 + 22, 0 [0. 87] Y1 Y1 - 13, 0 [0. 51] Y1 - 17, 7 [0. 70] Y1 - 52, 7 [2. 07]
X2
RAD 27, 5 [1. 08]
0, 000 [. 0000]
Y2 - 52, 7 [2. 07] Y2 - 17, 7 [0. 70] Y2 - 13, 0 [0. 51] Y2
View From Injection Side
Y2 + 22, 0 [0. 87]
X3
Plate features are noted on plan view and correspond to features in section view below.
X4
For HT / TS For HT / TS
26. 8 [1. 06]
40. 0 [1. 57]
12. 5 [0. 49]
3. 0 MIN [. 12]
8. 000 +0. 015 [. 3150 +. 0006]
*C
1/4 -20
M6
(2)
*B
80. 8 [3. 18]
BK-PLT
*B
6. 8 [. 27] MF-PLT 6. 8 x 17. 0 DP. 42. 0 [1. 66] [ . 32 +. 0001 x . 59 DP. ] 60. 01 +0. 03 [2. 36 +. 0001] 30. 0 MAX 1. 5R [1. 18] [. 06] 44. 01 +0. 03 [1. 733 +. 001] R 1. 5 [. 06] MAX 22. 2 [. 88] T/C MF-PLT THRU HOLE FOR X> 87 mm 22. 2 [. 88] T/C MF-PLT
T/C : Thermocouple BK - PLT : Manifold Backing Plate MF - PLT : Manifold Plate X : Pitch X Value Y : Pitch Y Value R, RAD : Radius C : Center Insulator Bore Depth* B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com Please confirm all dimensions and nozzle suitability by contacting Husky.
Min Pitch (X1, 2, 3, 4) Max Pitch (X1, 2, 3, 4) 53mm (2. 087") Min Pitch (Y1/Y2) 53mm (2. 087")
No. [. . . ] **Depending upon pitch values, dowel location will differ. Contact Husky for specific location, otherwise include both.
Step 2: Layout plate features using pitch dimension for X value
For HT / TS For VG /VX
M12 [1/2-13 UNC] (3 Bolts per drop recommeded)
MAX
MIN
Sharp
THRU HOLE FOR X > 87 mm
T/C : Thermocouple Step 3:Section view shown above corresponds to feature callouts (Ultra 500) planview. BK - PLT : Manifold Backing Plate
Gate Min X
HT
Max X Min Y1 Max Y1
Min Y2
Max Y2 Number of T/C's
2 T/C's Mounted Through Manifold Plate 2 T/C's Mounted 331mm Through Backing (13. 031") Plate (when required)
Electrical MF - PLT : Manifold Plate Zones X : Pitch X Value
Y : Pitch Y Value R, RAD : Radius 11 or 13 C : Center Insulator Bore Depth* B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com
>73. 0mm 211mm (2. 87") (8. 307") >73. 0mm 211mm (2. 87") (8. 307")
>61. 3mm Y2-45mm Y1 + 62. 0mm 331mm (2. 41") (1. 771") (2. 41") (13. 031") >61. 3mm Y2-50mm (2. 41") (1. 968") Y1+ 62. 0mm (2. 41")
VG
Please confirm all dimensions and nozzle suitability by contacting Husky. [. . . ]