User manual ICOM IC-F21

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ICOM IC-F21. We hope that this ICOM IC-F21 user guide will be useful to you.

Lastmanuals help download the user guide ICOM IC-F21.


Mode d'emploi ICOM IC-F21
Download

You may also download the following manuals related to this product:

   ICOM IC-F21 Instruction Manual (631 ko)

Manual abstract: user guide ICOM IC-F21

Detailed instructions for use are in the User's Guide.

[. . . ] INSTRUCTION MANUAL VHF TRANSCEIVER iF11/S UHF TRANSCEIVER iF21/S This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. SAFETY TRAINING INFORMATION Your Icom radio generates RF electromagnetic energy during transmit mode. This radio is designed for and classified as "Occupational Use Only", meaning it must be used only during the W ARN ING course of employment by individuals aware of the hazards, and the ways to minimize such hazards. This radio is NOT intended for use by the "General Population" in an uncontrolled environment. [. . . ] The following are additionally required: · One AD-99 (depends on version. ). · An AC adapter (may be supplied with the BC-144 depending on version). BP-209, BP-210 or BP-222 only AC adapter BC-145A/E/V/UK Check orientation. Charging indicator 7 BATTERY PACKS 3 D Rapid charging with the BC-144+AD-99 Turn power OFF BP-209, BP-210 or BP-222 attached to the transceiver. AC adaptor BC-145A/E/V/UK Check orientation and the spacer combination as follows. Charging indicator D Spacer combination. · Be sure to attach the spacer (Spacer B/C) to the adapter (Spacer A) Spacer A with the orientation as illustrated in the diagram at right. · Attach the spacer (Spacer B/C) to the adapter with the orientation of the stamp " Check orientation and Spacer B/C " pointing up. NOTE: Push the notch carefully when remove the spacer from the adapter. 8 3 BATTERY PACKS D Rapid charging with the BC-121+AD-94 (#11) The optional BC-121 allows up to 6 battery packs to be charged simultaneously. The following are additionally required. · Six AD-94 (#11) (Some versions require additional AD-99s). · An AC adapter (may be supplied with the BC-121 depending on version). Turn power OFF. NOTE: Output power is automatically reduced to 1 W to retain sufficient power in case of an emergency, etc. D CAUTIONS · Use ALKALINE batteries only. · Make sure all battery cells are the same brand, type and capacity. · Never mix old and new batteries. Either of the above may cause a fire hazard or damage the transceiver, if ignored. · Never incinerate used battery cells since internal battery gas may cause them to rupture. · Never expose a detached battery case to water. If the battery case gets wet, be sure to wipe it dry before using it. 11 PROGRAMMABLE FUNCTIONS ` General 4 In the following explanations, programmable function names are bracketed, the specific switch used to activate the function depends on programming. D KEY LOCK FUNCTION1/2 This function locks access to all programmable switches (except the switch assigned for the lock function): Lock1: All Key Lock (except Lock key). Push and hold the [Lock1] or [Lock2] switch for 1 sec. · This function may be inhibited on some channels. D PRIORITY CHANNEL This function is used to select a pre-programmed channel at the push of a switch. Push the [PrioA], [PrioA(Rewrite)] or [PrioB] switch to select the priority channel. · Priority channel is automatically selected. 12 4 PROGRAMMABLE FUNCTIONS D SCAN FUNCTION The scan function allows you to search a pre-programmed group of channels for signals. Push the [Scan] switch to start/stop scan. [. . . ] · When cloning is finished, a "Beep" tone is emitted two times. NOTE: DO NOT push the [PTT] on the slave transceiver during cloning. This will cause a cloning error. r When cloning is finished, turn power off, then on again to return to normal operation. D PC-to-transceiver cloning Please refer to the HELP file that comes with the CS-F11 CLONING SOFTWARE. CAUTION: Imprudent cloning operation causes a cloning error. In such a case, memory contents may be lost. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-F21

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-F21 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag