Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ICOM IC-H19S3. We hope that this ICOM IC-H19S3 user guide will be useful to you.
Lastmanuals help download the user guide ICOM IC-H19S3.
Detailed instructions for use are in the User's Guide.
[. . . ] Personal injury, fire hazard or electric shock may occur. No risk of personal injury, fire or electric shock.
SAVE THIS INSTRUCTION MANUAL -- This
i
Icom, Icom Inc. and the Icom logo are registered trademarks of Icom Incorporated (Japan) in Japan, the United States, the United Kingdom, Germany, France, Spain, Russia and/or other countries. LTR is a registered trademark of the E. F. Johnson Company. [. . . ] ZONE TYPE: To select the desired zone: · Push [Zone], then push [CH Up] or [CH Down]. · Rotate [ROTARY SELECTOR]*.
- Up to pre-programmed 16 zones can be selected.
D Voting operation The transceiver automatically starts scanning when a zone, specified for the voting operation, is selected. The voting scan detects the S-meter of the repeater and automatically selects the strongest station.
12
3
BASIC OPERATION
Call procedure
When your system employs tone signalling (excluding CTCSS and DTCS), this call procedure may be necessary prior to voice transmission. The tone signalling employed may be a selective calling system which allows you to call specific station(s) only and prevent unwanted stations from contacting you. q Select the desired TX code channel or 2/5-tone code according to your System Operator's instructions.
· This may not be necessary depending on programming. · Refer to pages 14 or 15 for selection.
Receiving and transmitting
NOTE: Transmitting without an antenna may damage the transceiver. Receiving: q Rotate [VOL] to turn the power ON. w Push [CH Up] or [CH Down], or rotate [ROTARY SELECTOR]* to select the conventional system channel, in sequence.
*Depending on the pre-setting.
w Push [Call] (assigned to one of the dealer programmable keys) e After transmitting, the remainder of your communication can be carried out in the normal fashion.
Selective calling Non-selective calling
e When receiving a call, adjust the audio output level to a comfortable listening level. Transmitting: Wait for the channel to become clear to avoid interference. q While pushing and holding [PTT], speak into the microphone at a normal voice level.
· When a tone signalling system is used, the call procedure described at the previous page may be necessary.
w Release [PTT] to return to receive. IMPORTANT: To maximize the audio quality of your signal; 1. e Push [DTMF Autodial] to transmit the DTMF code.
i Push [Call] to transmit.
15
BASIC OPERATION
3
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
User set mode
User set mode is accessed at power ON and allows you to set seldom-changed settings. You can "customize" the transceiver operation to suit your preferences and operating style. Entering the user set mode: q While pushing and holding [P1] and [P2], rotate [VOL] to turn the power ON.
· Turn power OFF in advance. · "SET MODE" appears for 1 sec at power ON.
Emergency transmission
When [Emergency] is pushed for the specified time period, an emergency signal is automatically transmitted. 9) When [Emergency] is pushed for the specified time period, the DTMF or 5-tone* emergency signal is transmitted once or repeatedly on the emergency channel. However, when no emergency channel is specified, the signal is transmitted on the previously selected channel. If you want to cancel the emergency call, push and hold the key again before transmitting the call. *Depending on the operating model type.
w Push and hold [P0] to enter user set mode. e Push [P0] several times to select the appropriate item. Then push [Side2] or [Side3] to set the desired level/condition.
· Available set mode functions are Backlight, LCD contrast, Beep, Beep Level, Ringer Level, SQL Level, AF Min Level, Mic Gain, VOX Gain*, VOX Delay*, Battery Voltage, Signal Moni, Lone Worker and System Info. * Appears only when the external VOX unit is connected.
Man Down Emergency Call
This function requires the optional UT-124R man down unit and can be performed in conventional mode. [. . . ] · UT-126H digital modulator/demodulator unit Provides 6. 25 kHz digital mode operation. · UT-124R man down unit Provides a measure of safety when working in a hazardous environment, etc.
OPTIONS D DC CABLES D ANTENNAS
8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
· CP-17L cigarette lighter cable Allows charging of the battery pack through a 12 V cigarette lighter socket. (For BC-119N) · OPC-515L/OPC-656 dc power cables Allows charging of the battery pack using a 13. 8 V power source instead of the AC adapter. OPC-515L : For BC-119N OPC-656 : For BC-121N
D OTHER OPTIONS
· SP-13 earphone Provides clear receive audio in noisy environment. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-H19S3
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-H19S3 will begin.