Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ICOM IC-PCR1500. We hope that this ICOM IC-PCR1500 user guide will be useful to you.
Lastmanuals help download the user guide ICOM IC-PCR1500.
Detailed instructions for use are in the User's Guide.
[. . . ] INSTRUCTION MANUAL
COMMUNICATIONS RECEIVERS
iPCR1500 iPCR2500
FOREWORD
Thank you for purchasing this Icom receiver. The IC-PCR1500/ PCR2500 COMMUNICATIONS RECEIVERS is designed and built with Icom's state of the art technology and craftsmanship. With proper care, this receiver should provide you with years of trouble-free operation.
IMPORTANT
READ ALL INSTRUCTIONS carefully and completely
before using the receiver.
SAVE THIS INSTRUCTION MANUAL-- This instruction manual contains important operating instructions for the IC-PCR1500/PCR2500.
D FEATURES
[Common to both models] Wide frequency coverage with all mode receive Real-time bandscope function IF shift function ANF and NR functions are available
(Only when the DSP unit is installed. )
EXPLICIT DEFINITIONS
DEFINITION Personal injury, fire hazard or electric shock R WARNING!CAUTION NOTE Equipment damage may occur. [. . . ] eClick the close ([X]) button to close the [WX Alert] screen. r Click the zWXx button to turn the weather alert function ON. t When the alert is detected, a beep sounds and the indication will be displayed as at right. y Click the zWXx button to turn the weather alert function OFF. NOTE: While receiving a signal (on a frequency other than the weather alert ON frequency), the receiving signal or audio will be interrupted momentarily every 5 sec. (approx. ) in case the alert function is turned ON. This is caused by the WX alert function. To eliminate the interruptions, set the weather alert function to OFF. 62
· [Receiver] screen IC-PCR1500 IC-PCR2500
zWXx Active band only · [Compo] screen IC-PCR1500
IC-PCR2500
METER/SCAN PANEL
MAIN
SUB · [WX Alert] screen
zWXx
e Click q Click Click to monitor the selected weather channel.
w Select · [Simple] screen IC-PCR1500 IC-PCR2500
MAIN IC-PCR1500
SUB IC-PCR2500
zWXx
zWXx
zWXx
BASIC RECEIVE FUNCTIONS
5
Squelch delay setting
· [Receiver] screen IC-PCR1500 IC-PCR2500
Select squelch delay from short and long to prevent repeated opening and closing of the squelch during reception of the same signal. · Long : Long squelch delay.
SUB Appears
5
MAIN
Appears Blinks · [Compo] screen IC-PCR1500 IC-PCR2500
q Click the zSettingx icon on the tool bar to call up the [Setting] screen if it is not displayed. w Click the zOthersx tab to display the squelch delay setting. e Click the zShortx or zLongx radio button to set the squelch delay. rClick the close button ([X]) to close the [Setting] list screen. IC-PCR1500 IC-PCR2500
zSettingx e Click
Appears TUNING PANEL METER/SCAN PANEL MAIN SUB Appears
Blinks · [Simple] screen IC-PCR1500 IC-PCR2500
q Click
w Select
MAIN Appears
SUB Blinks
63
5
BASIC RECEIVE FUNCTIONS
Single band/Dualwatch operation (IC-PCR2500 only)
Dualwatch operation monitors two frequencies simultaneously. The IC-PCR2500 has two independent receiver circuits: Main band, and Sub band (available frequencies, operating
mode and functions are different depending on bands). · [Receiver] screen Dualwatch operation
Single band operation is useful when only one frequency is being watched. The single band operation's control screens are similar as the ICPCR1500. Click the zSinglex icon on the tool bar to toggle between the single band operation and the dualwatch operation.
· Even when click the zSinglex icon during Sub band operation, the control screen switches to the Main band frequency automatically.
Single band operation zSinglex
When the dualwatch operation is in use, IC-PCR2500 must be connected to two antennas. ([ANT1] and [ANT2])
64
BASIC RECEIVE FUNCTIONS
5
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
65
· [Compo] screen Dualwatch operation
Single band operation
· [Simple] screen Dualwatch operation
Single band operation
5
BASIC RECEIVE FUNCTIONS
Diversity operation (IC-PCR2500 only)
The diversity receiving compares the receiving signal strength from two different antennas, ANT1 and ANT2, and automatically selects the strongest signal. This feature is useful when you are listening in a moving vehicle or the transmitting station itself is moving. Diversity receiving is available from 50 MHz to 1300 MHz on FM, P25 and DV mode only. · With the squelch open in FM mode while receiving a weak signal, diversity receiving does not work properly. [. . . ] : 0. 010000809. 999999 *1, *2 851. 000866. 999999 896. 0001300. 000000 1300. 0000011810. 999999 *1 1852. 0001867. 999999 *1 1897. 0002305. 899999 *1 2357. 0002811. 999999 *1 2853. 0002868. 999999 *1 2898. 0003109. 799999 *1, *2 3136. 0003154. 799999 *1, *2 3181. 0003299. 999999 *1, *2 France : 0. 01000029. 999999 *1, *2 50. 20051. 200000 87. 500107. 999999 144. 000146. 00000 430. 000440. 00000 1240. 0001300. 00000 Other than above : 0. 0103299. 999999 *1, *2 *1 : For IC-PCR2500/R2500. Sub band does not cover outside of frequency range; 50 to 1300. 000000 MHz. Guaranteed: 0. 4953000. 000 MHz range only
· Number of memory channels Main unit : 2600 Controller [R1500/R2500] : 1100 (incl. 100 scan edges) · Tuning steps : 1 Hz*, 10 Hz, 20 Hz, 50 Hz, 100 Hz, 500 Hz, 1 kHz, 2. 5 kHz, 5 kHz, 6. 25 kHz, 8. 33 kHz, 9 kHz, 10 kHz, 12. 5 kHz, 15 kHz, 20 kHz, 25 kHz, 30 kHz, 50 kHz, 100 kHz, 125 kHz, 150 kHz, 200 kHz, 500 kHz, 1 MHz, 10 MHz*, USER TS*
*PC operation only
· Operating temperature range PC operation : 0°C to +60°C; +32°F to +140°F Controller operation [R1500/R2500] : 10°C to +60°C; +14°F to +140°F · Frequency stability : ±3 ppm (10°C to +60°C) · Power supply requirement : 12. 0 V DC ±15% · Current drain (at 12. 0 V DC: approx. ) [1500]
While using controller (R1500): plus 50 mA with below current value.
· Antenna connector : BNC (50 ) · Dimensions (proj. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-PCR1500
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-PCR1500 will begin.