Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ICOM IC-T3H. We hope that this ICOM IC-T3H user guide will be useful to you.
Lastmanuals help download the user guide ICOM IC-T3H.
You may also download the following manuals related to this product:
ICOM IC-T3H BROCHURE (625 ko)
Manual abstract: user guide ICOM IC-T3H
Detailed instructions for use are in the User's Guide.
[. . . ] INSTRUCTION MANUAL
VHF TRANSCEIVER
iT3 H
FOREWORD
Thank you for purchasing the IC-T3H FM transceiver. This transceiver is designed for those who require quality, performance and outstanding reliability under the most demanding conditions.
IMPORTANT
READ ALL INSTRUCTIONS carefully and completely before using the transceiver. SAVE THIS INSTRUCTION MANUAL This instruction manual contains important operating instructions for the transceiver.
EXPLICIT DEFINITIONS
The explicit definitions below apply to this instruction manual.
WORD R WARING CAUTION NOTE DEFINITION Personal injury, fire hazard or electric shock may occur. No risk of personal injury, fire or electric shock.
Icom, Icom Inc. [. . . ] w Rotate [VOL] to select the desired channel. e Push [A·FUNC], then push [0·DTMF-M] for
1 sec. to enter the DTMF programming mode.
· "_ _ _ _ _" appears. · Programmed memories can be cleared in this way. r Push the digit keys, [A·FUNC], [B·CALL], [C·MR], [D·CLR], [·OPTION]
and [#·ENT
] to enter the desired DTMF code.
· A maximum of 24 digits can be input. · [·OPTION] enters as "E", [#·ENT ] enters as "F. " · If a digit is mistakenly input, push [SQL] or [PTT] momentarily then repeat from step q. t Push [SQL] or [PTT] to input the digits and exit the DTMF pro-
gramming mode.
· Programmed DTMF codes sound when [SQL] is pushed to exit.
27
DTMF MEMORY
7
I Transmitting a DTMF code
D Using a DTMF memory channel
q Push [A·FUNC], then push [0·DTMF-M] to enter the DTMF mem-
ory.
w Rotate [VOL] to select the desired channel. e Push [SQL] or [PTT] to exit the DTMF memory mode. r While pushing [PTT], push [SQL] to transmit the selected DTMF
memory.
· After the DTMF code is transmitted, the transceiver returns to receive automatically.
D Manual DTMF code transmission
While pushing [PTT], push digit keys, AF to transmit a DTMF code manually.
USING INITIAL SET MODE I DTMF transmission speed
When slow DTMF transmission speeds are required with DTMF memory transmission (as for some repeaters), the transceiver's rate of DTMF transmission can be adjusted.
q While pushing [Y] and [Z], turn the power
F MR TX
on to enter INITIAL SET MODE. w Push [Y]/[Z] several times until "dtd" appears. e Rotate [VOL] to select the desired DTMF transmission speed.
F MR
TX
· Four speeds are available: "1" (100 msec. intervals) is the fastest; "5" (500 msec. r Push [#·ENT
] to exit INITIAL SET MODE.
28
I Scan types
PROGRAMMED SCAN
Band edge
1A 2A 3A Scan edges Scan Jump 1b 2b 3b
8
SCAN OPERATION
Band edge
MEMORY (SKIP) SCAN
SKIP
Mch 1 Mch 0 Mch 99 Mch 10 Mch 9 Mch 8 Mch 7 Mch 2 Mch 3 Mch 4 Mch 5 Mch 6
SKIP
PRIORITY WATCH
Priority memory channel watch
VFO frequency 145. 20 MHz 5 sec.
Mch 3
Priority channel
50 msec.
Mch 3 Mch 2 Mch 4
Priority memory channel scan
VFO frequency 145. 20 MHz 5 sec. 50 msec.
Memory scan
Mch 1
SKIP
Mch 5
Priority channel
Mch 99 Mch 6
29
SCAN OPERATION
8
I Programmed scan
Programmed scan repeatedly scans between two user programmed frequencies (memory channels "1A3A" and "1b3b") or scans between upper and lower band edges. This scan is useful for checking for signals within a specific frequency range such as repeater output frequencies, etc. q Push [D·CLR] to select VFO mode, if necessary. w Push [A·FUNC], then push [5·SCAN] to start the scan, then a selected scan edge appears as "P1", "P2", "P3" or "AL. "
· To change the scan edge, push [A·FUNC] then push [8·SET] several times until the desired scan edge appears. · "AL" for full scan, "P1", "P2" and "P3" for programmed scan between the programmed scan edge channels as "1A""1b", "2A""2b" and "3A""3b". · To change the scan direction, push [Y] or [Z]. · When "dial" is assigned [VOL], rotate [VOL] to change the scan direction. 50)
e Push [D·CLR] to stop the scan.
NOTE: Scan edges, 1A3A/1b3b, must be programmed in advance. Program them in the same manner as regular memory channels. [. . . ] 4 hrs.
Battery case for R6 (AA) ×6 alkaline cells
7. 2 V 7. 2 V 7. 2 V
1100 mAh 1650 mAh 600 mAh
*1Operating periods are calculated under the following conditions: Tx:Rx:standby=5:5:90, power save function: auto setting, is activated *2Operation with the LOW output power selection is recommended.
D CHARGER · BC-144 DESKTOP CHARGER + BC-145 AC ADAPTER For rapid charging of battery packs. An AC adapter is supplied with the charger. · BC-137 (#11) BATTERY CHARGER + BC-122 AC ADAPTER For regular charging of battery packs. · BC-146 BATTERY CHARGER + BC-147 AC ADAPTER For regular charging of battery packs. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-T3H
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-T3H will begin.