Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ICOM IC-T42E. We hope that this ICOM IC-T42E user guide will be useful to you.
Lastmanuals help download the user guide ICOM IC-T42E.
You may also download the following manuals related to this product:
ICOM IC-T42E BROCHURE (273 ko)
Manual abstract: user guide ICOM IC-T42E
Detailed instructions for use are in the User's Guide.
[. . . ] This connection will ruin the transceiver.
NEVER cut the DC power cable between the DC plug and
EXPLICIT DEFINITIONS
DEFINITION Personal injury, fire hazard or electric shock RWARNING may occur. CAUTION NOTE Equipment damage may occur. No risk of personal injury, fire or electric shock. If an incorrect connection is made after cutting, the transceiver might be damaged.
NEVER place the transceiver where normal operation of the vehicle may be hindered or where it could cause bodily injury. [. . . ] · Select a DTMF channel after pushing the [DTMF] key. · Select a scan group after pushing and holding the [SCAN] key.
CH 1 CH 2 CH 3 CH 4
OPERATING CHANNEL KEYS Select an operating channel directly.
SCAN TAG KEY Adds or deletes the selected channel to the scan group. BEEP Push to turn the beep tones ON/OFF.
BEEP
3
PANEL DESCRIPTION
LOCK KEY Electronically locks all programmable keys except the following: · [CALL] (incl. CAL A and CAL B), [MONI] and [EMER] keys. MONITOR KEY Activates one of (or two of) the following functions on each channel independently:
· Push and hold the key to unmute the channel (audio is emitted; `Audible' condition). · Push the key to toggle the mute and unmute conditions (toggles `Audible' and `Inaudible'). · Push the key to mute the channel (sets to `Inaudible' only). · Push the key to unmute the channel (sets to `Audible' only). · Push the key after the communication is finished to send a `reset code'.
1
LOCK
HIGH LOW1
OUTPUT POWER SELECTION KEYS Select the transmit output power temporarily or permanently depending on the pre-setting.
level for each selection.
LOW2 · Ask your Dealer or System Operator for the output power
MONI
TA
TALK AROUND KEY Turns the talk around function ON and OFF.
· The talk around function equalizes the transmit frequency to the receive frequency for mobile-to-mobile communication.
CALL CAL A CAL B
CALL KEYS Transmit a 5-tone call.
· Call transmission is necessary before you call another station depending on your signaling system. · The [CAL A] and/or [CAL B] keys may be available when your system employs selective `Individual/Group' calls. Ask your System Operator which call is assigned to each key.
NOTE: The unmute condition (`Audible' condition) may automatically return to the mute condition (`Inaudible` condition) after a specified period.
W/N
EMER
EMERGENCY KEY Push and hold the key to transmit an emergency call.
· If you want to cancel the emergency call, push (or push and hold) the key again before transmitting the call. Therefore "1234" and "6789" are the same.
KEY NUMBER
P0 P1 P2 P3
0 5
1 6
2 7
3 8
4 9
e When the "PWORD" indication does not clear after inputting 4 digits, the input code number may be incorrect. Turn power off and start over in this case.
AUTOMATIC SCAN TYPE: Channel setting is not necessary for this type. When turning the power ON, the transceiver automatically starts scanning. Scanning stops when receiving a call or when taking the microphone off hook.
6
2
OPERATION
IMPORTANT: To maximize the readability of your signal:
(1) pause briefly after pushing [PTT], (2) hold the transceiver 15 to 20 cm from your mouth, then speak into the microphone at a normal voice level.
I Receiving and transmitting
RECEIVING: I q Push [K ] to turn the power ON. e When receiving a call, adjust the volume [UP] or [DOWN] to a comfortable listening level.
D Transmitting notes
TRANSMITTING: r Take the microphone off hook.
· 5-tone mute may be released (the `audible' condition is selected and " " appears). · A priority channel may be selected automatically.
· Transmit inhibit function The transceiver has several lockout/inhibit functions which restrict transmission under the following conditions:
· The channel is in mute condition (`Inaudible' condition; " does not appear). · No matched (or matched) CTCSS is received. · The selected channel is a `receive only' channel. "
t Wait for the channel to become clear.
· The channel is busy when " " appears.
y Push the [CALL] key when initiating a call from your side.
· Coded audio may be heard from the transceiver, then " " appears. · This operation may not be necessary depending on your signaling system. Ask your System Operator or Dealer.
u While pushing and holding [PTT], speak into the microphone at your normal voice level. [. . . ] Japan
1-1-32, Kamiminami, Hirano-ku Osaka 547-0003, Japan Declare on our sole responsibility that this equipment complies the essential requirements of the Radio and Telecommunications Terminal Equipment Directive, 1999/5/EC, and that any applicable Essential Test Suite measurements have been performed. Kind of equipment: Type-designation: VHF TRANSCEIVER
0168
Düsseldorf 07 Feb. 2001 Place and date of issue
iC- f310/s
146174 MHz 12. 5 KHz/ 20 KHz/ 25 KHz
Icom (Europe) GmbH
Himmelgeister straße 100 D-40225 Düsseldorf Authorized representative name
Version (where applicable): This compliance is based on conformity with the following harmonised standards, specifications or documents:
i) EN300 279 v1. 2. 1(1999-02) (EMC product standard) ii) EN60950 August 1992, A11 1997 (Safety of information technology equipment) iii) ETS300 086 January 1991 (Radio equipment for analog speech) iv) I-ETS300 219 October 1993 (Radio equipment transmitting signals) v)
Icom (Europe) GmbH
T. Aoki General Manager
Signature
ABOUT CE
CE Versions of the IC-F310/S which display the "CE" symbol on the serial number seal, comply with the essential requirements of the European Radio and Telecommunication Terminal Directive 1999/5/EC.
INSTALLATION NOTES
The installation of this equipment should be made in such a manner as to respect the EC recommended electromagnetic field exposure limits (1999/519/EC). [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-T42E
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-T42E will begin.