[. . . ] INSTRUCTION MANUAL
MARINE RADAR
MR-1000RTM (Radome type) MR-1000TTM (Open array type)
SYSTEM COMPONENTS
MODEL NAME MR-1000RII MR-1000TII CRT DISPLAY SX-2713 (10-inch CRT) SX-2779 (10-inch CRT) SCANNER UNIT EX-2714 (Radome type) EX-2780 (Open array type)
SUPPLIED ACCESSORIES
· EX-2714 (Radome type unit) Qty. q System cable (OPC-1188: 15 m) . . . . . . . . . . . . . . . . . . . . . . . . . 1 w Installation bolts (M10×50) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 e Installation bolts (M10×25) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] w Push [Ú] until the "IR" section becomes highlighted. e Push [ ] to select IR function 1, 2 or OFF.
· "IR" appears in the upper right of the screen, when the function is activated. Radar interference With IR function ON
I STRETCH function
The blips can be magnified electronically for easier viewing of small targets. 6) q Push [MENU]/[ ] to open the VIDEO menu. w Push [Ú] to select "STRETCH", then push [] to turn the function ON. NOTE: Turn OFF this function during normal operation.
Normal screen With STRETCH ON
I ZOOM function
The ZOOM function expands the target to two times normal size.
· This function is available up to a 24 NM range or shorter except 1/8 NM.
q Push [Ù Ú ] to move the cursor to the desired target. w Push [TARGET]/[ ] and [TRAILS]/[ ] simultaneously to toggle the ZOOM function ON and OFF.
Normal screen With ZOOM function ON
· "ZOOM" appears in the lower right of the screen.
11
4
BASIC OPERATION
I TRAILS function
The trails function memorizes echoes continuously or at constant intervals. This is useful for watching other ships' tracks, approx. relative speed, etc.
Trail time
CURS STW 15. 7KT
· Setting the trail interval time q Push [MENU]/[ ] twice to call up the VIDEO menu.
· Push [Ú] several times until the "TRAIL TIME" section becomes highlighted.
TRAIL indicator Trail interval counter
w Push [ ] to select trail interval time.
· 6 sec. , 15 sec. , 30 sec. , 1 min. , 3 min. , 6 min. , 15 min. and (continuous) are available.
3/4 NM
(0. 25) M. T U N E
011. 4° R H UP
T. V E C T 6 M TRAILS 0. 453N M 1:0 5 HDG 253. 9°T
IR ES
e Push [MENU] several times to exit the menu. · Using the TRAILS function q Push [TRAILS]/[ ] to turn the trail function ON.
· "TRAILS" and trail interval time appears in the upper right of the screen. · Trail interval counter starts to count up to the trail time.
Trail time
w All displayed echoes at the plotted time are memorized and displayed with a graduated intensity together with the current echoes.
· Echoes are displayed with minimum intensity when "" is selected.
e Push [TRAILS]/[ ] to cancel the trail function and erase the plotted echoes.
· "TRAILS" and trail interval time disappears.
I Power save function
The power save function conserves the boat's battery power by pausing the transmission. The standby (pausing) times are selectable (rotation number is fixed to 10). is selected, the scanner rotates 10 revolutions; then stops for 1 min. , and then repeats this sequence while the power save function is activated.
Count down the standby time
NM C U R S SOG17. 7KT
D Setting the scanning standby time q Push [MENU]/[ ] four times to call up the INT. w Push [Ú] until the "SAVE TIME" section becomes highlighted. e Push [ ] to select standby time.
· 1, 6, 15, and 30 min. are available.
r Push [MENU]/[
] twice to exit the menu display. to
D Using the power save function q Push and hold [TX (SAVE)]/[ turn the power save function ON.
1
(0. 25)
S AV E
0 1 4 . 6° T H UP
T. V E C T 6 M 0:48 0. 9 0 0 N M HDG273. 9°T IR ES
NM C U R S SOG17. 7KT
1
(0. 25)
S AV E
0 1 4 . 6° T H UP
T. V E C T 6 M 0:00 0. 9 0 0 N M HDG273. 9°T IR ES
· The save indicator appears in the top of the screen.
w After the scanning rotations are finished, transmission and rotation are suspended until the selected standby time elapses.
· The display shows the last scanned echoes until the scanning restarts. · "SAVE" and standby time appear in the top of the screen and the standby time is counted down.
GPS COMPASS
GPS COMPASS
EBL1 EBL2 MOB CURS
VRM1 VRM2 34° 37. 72N 1 3 5 ° 3 4 . 4 2 E
EBL1 EBL2 MOB CURS
VRM1 VRM2 34° 37. 72N 1 3 5 ° 3 4 . 4 2 E
Push and hold [TX] for 1 sec. to turn the SAVE function on.
Scan and STBY alternates
e After the selected standby time elapses, transmission and rotation restart. [. . . ] *3 Push any key to cancel the error message and beep tone. *4 Turn the power OFF, then check the system cable connections.
35
13
MAINTENANCE
Continued, reliable operation of the radar depends on how you care for your equipment. The simple maintenance tips that follow can help you save time and money, and avoid premature equipment failures.
I Periodic maintenance
WARNING: BE SURE the power is OFF before
performing any maintenance. q Keep the equipment as clean as possible.
· Use a soft cloth to remove dirt, dust and water.
w Check all hardware for loose screws, bolts, etc. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM MR-1000RII
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.