Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual IDEAL 61-361. We hope that this IDEAL 61-361 user guide will be useful to you.
Lastmanuals help download the user guide IDEAL 61-361.
Detailed instructions for use are in the User's Guide.
[. . . ] #61-361
IDEAL Test Pro®
360 Series True RMS Multimeter
WARNING!DO NOT UNDER ANY CIRCUMSTANCES EXCEED THESE RATINGS: - Voltage is not to exceed 600V AC or DC. - Resistance, Capacitance, Logic, and Continuity functions are not to be performed on circuits capable of delivering greater than 500V AC or DC. - Current measurements are not to be performed on circuits capable of delivering greater than 600V AC on insulated conductors, 250V AC on uninsulated conductors. [. . . ] The diode test function allows measurements of forward and reverse bias across diodes and transistor junctions. Turn off power to the device or circuit that is being tested and discharge all capacitors. Plug the leads into the meter inputs as indicated in the above diagram. Select the diode function on the meter.
Page 9
Page 10
Continuity Beeper (beeps at resistance <150)
Current (AAC and ADC)
PHASE ROTATION-TRUE RMS HZ-MFD-AUTO OFF
VAC
PHASE ROTATION-TRUE RMS HZ-MFD-AUTO OFF
2000m 200m RST Hz 200M 2000m RST Hz 200M 20M 200 200m 20M
600 200
600 200
VDC
200m
20 2000m 200m
VAC
2000m 200m
600 200
600 200
VDC
20
ADC AAC
200 2k 20k
ADC AAC
200 200k 20k 2k 200 20k 2k
ADC AAC
200k 20k 2k 200 20k
MFD
MFD
2A MFD
CAT. LLL 600V
M 200k 20k 2k 200 20k
2k
MFD
R/L1
MAX 2A FUSED
COM !
600V MAX 350V/15 SEC FOR 200mV RANGE
V
2A MFD
CAT. R/L1
MAX 2A FUSED
V
A D
600V MAX 350V/15 SEC FOR 200mV RANGE
Red Red Black
Black
Function AC Current DC Current Range 2. 000 A 2. 000 A Resolution . 001 A . 001 A Accuracy ± (3. 0% + 4) 50 to 500Hz
To Verify Continuity: A continuity test ensures that all circuit connections are intact. Plug the test leads into the meter inputs as indicated in the diagram above. Turn the power off to the circuit or device that is to be verified. Select the continuity function on the meter. The continuity function is located at the 2k setting. Test for continuity by connecting the meter to the circuit. If the beeper sounds, the circuit is complete.
To Measure Current: Current is measured in amps. Do not attempt to measure current in circuits capable of delivering greater than 600V. Connect the test leads into the meter inputs as indicated in the diagram above. Connect the meter in series with the load or circuit. Measure the Current.
Page 11
Page 12
Frequency (Hz)
Phase Rotation (RST)
PHASE ROTATION-TRUE RMS HZ-MFD-AUTO OFF
VAC
2000m 200m RST Hz 200M 20M k
PHASE ROTATION-TRUE RMS HZ-MFD-AUTO OFF
200
VAC
2000m 200m RST
600 200
600 200
VDC
20 2000m 200m
VAC
2000m 200m RST Hz 200M 20M 200k
2A MFD 2000m 200m RST Hz 200M 20M
600 200
600 200
VDC
20 2000m 200m
Hz 200M 20M
ADC AAC
200 200k 20k 2k 200 20k 2k
ADC AAC
200 200k 20k 2k 200 20k 2k
MFD
MFD
2A MFD
CAT. R/L1
MAX 2A FUSED
V
R/L1
MAX 2A FUSED
600V MAX 350V/15 SEC FOR 200mV RANGE
R
600V MAX 350V/15 SEC FOR 200mV RANGE
T
Red Black
Function Phase Rotation Indicator
S
Frequency Range 50 Hz to 500 Hz
Voltage Range 80V to 500V LCD indicates sequence of three-phases.
Function Range Resolution Accuracy Frequency 10 Hz to 100 kHz for AC ±(2% + 3 digits) 10 Hz to 100 Hz for DC* . 001 kHz Sensitivity : 3. 5 V rms
*DC Voltage higher than 3. 5 V rms
To Determine Phase Rotation (RST): This test function correctly identifies each of the 3-Phases in a power panel as R, S, T. Note: The displayed numerical value has no meaning when performing this procedure. Maximum 3 phase voltage allowed in this mode is 500 VAC. Turn power off to the circuit that is to be tested. Place the function switch on the meter to "RST. " 3. Plug the test leads into the meter inputs labeled as R, S, T in the diagram above. [. . . ] Page 17
Page 18
WARNING To prevent electrical shock hazard, turn off the multimeter and disconnect test leads before removing the back cover. Disconnect the test leads and turn the meter off. Remove the test leads from the front terminals. Lift the end of the case back until it gently unsnaps. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE IDEAL 61-361
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual IDEAL 61-361 will begin.