1
490 Series
Industrial Grade Multimeter
~Hz
MIN/MAX
7 8
PEAK
HOLD
10 14 13
9
12 11 2
3
Data Acquisition
4
~Hz
MIN/MAX
PEAK
HOLD
5
2
6
Data Acquisition
2
1. DO NOT UNDER ANY CIRCUMSTANCES EXCEED THESE RATINGS: - Voltage is not to exceed 1000 Volts. - Resistance, Capacitance, Logic and Continuity functions are not to be performed on circuits capable of delivering greater than 600 Volts. - Current measurements are not to be performed on circuits capable of delivering greater than 500 Volts 2. [. . . ] Push the blue button until AC is shown on the display. Connect the meter in series with the load or circuit. Frequency Response: 40Hz ~ 1kHz Overload Protection: 1A, 600V IR 10kA fuse for mA input 15A, 600V IR 100kA fuse for A input
To Measure DC Current: 1. Plug the Black test lead into the COM port and the Red test lead into the mA or A port. Set the rotary switch to the mA or A position. Push the blue button until DC is shown on the display. Connect the meter in series with the load or circuit. Overload Protection: 1A, 600V IR 10kA fuse for mA input 15A, 600V IR 100kA fuse for A input
9
10
Frequency/RPM Circuit Connection:
Resistance (Ohms) Circuit Connection:
~Hz
MIN/MAX
PEAK
HOLD
~Hz
MIN/MAX
PEAK
HOLD
Data Acquisition
Data Acquisition
2
2
Range 4kHz/40kRPM
Resolution 1Hz/30RPM
Max Display Sensitivity Accuracy 4. 000/40. 00 150mV 2. 0 Hz 1. 5V < 20 Hz Frequency: 0. 01% +1 RPM: 0. 01% + 10
40kHz/400kRPM 400kHz/4MRPM 4MHz/40MRPM 40MHz/400MRPM
10Hz/300RPM 100Hz/3KRPM 1kHz/30KRPM
40. 00/400. 0 400. 0/4. 000 4. 000/40. 00 300mV 1V ***
Range 400 4k 40k 400k 4M 40M
Resolution 0. 1 1 10 100 1K 10K
Max Display 400. 0 4. 000 40. 00 400. 0 4. 000 40. 00
Accuracy ±(0. 7% +3) ±(0. 4% +2)
±(0. 6% +3) ±(1. 5% +5)
10kHz/300KRPM 40. 00/400. 0
400MHz/4000MRPM 100kHz/3MRPM 400. 0/4000
*This spec is not guaranteed. Plug the Black test lead into the COM port and the Red test lead into the VHz port. Set the rotary switch to the HZ RPM position. For RPM, Push the blue button until RPM is shown on the display. Connect the meter in parallel with the load or circuit. Overload Protection: 600V 11
To Measure Resistance: 1. Turn the power off to the circuit or device that is to be measured and discharge all capacitors before attempting a measurement. Plug the Black test lead into the COM port and the Red test lead into the VHz port. For correct reading, ensure that the device being tested contains no voltage. Press the range button to select the proper range of the meter. Overload Protection: 600V Open Circuit Voltage: -1. 3V (approx. )
12
Capacitance Circuit Connection:
Diode Testing Circuit Connection:
~Hz
MIN/MAX
PEAK
HOLD
~Hz
MIN/MAX
PEAK
HOLD
Data Acquisition
Data Acquisition
2
2
Range 4nF 40nF 400nF 4µF 40µF 400µF 4mF 40mF
Resolution 1pF 10pF 100pF 1nF 10nF 100nF 1µF 10µF
Max Display Accuracy 4. 000 +(3. 0% +10) 40. 00 +(3. 0% +5) 400. 0 4. 000 40. 00 400. 0 4. 000 +(5. 0% +20)* 40. 00
Function Resolution Accuracy Max. Open Current Circuit Voltage 1. 5mA 3V 1mV +(1. 5% +5) * For 0. 4V to 0. 8V. Turn off power to the device or circuit that is being tested and discharge all capacitors. Plug the Black test lead into the COM port and the Red test lead into the VHz port. Press the blue button until is shown on the display 5. [. . . ] Power Requirements: IEC LR03, AM4 or AAA size 1. 5V x 2. Dimensions (WxHxD): 90mmx200mmx42mm, with out holster 100mmx212mmx55mm, with holster Accessories: Protective Holster, battery (installed) instruction manual, test leads.
C
US
Environmental Conditions Indoor use. Installation Category: IEC 1010, 1000V Cat. III Pollution Degree: 2
21
22
Maintenance Warning To avoid electrical shock, remove test lead before opening the cover. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE IDEAL ND2385
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.