[. . . ] #61-802
1
800 Series
Power Clamp Meter
61-802
Power Clamp
3ØPF AC+DC 2000KW 2000A
HOLD
3 4
2
PFKW HzV VA
OFF
KVARKVA 3Ø3W 3Ø4W
True RMS
5
61-802
DC A/W ZERO
REC
3Ø KVAR KVA
READ NEXT
6
CAT III - 600V
Power Clamp
3ØPF AC+DC 2000KW 2000A
HOLD
PFKW HzV VA
OFF
7
KVARKVA 3Ø3W 3Ø4W
True RMS
DC A/W ZERO
REC
3Ø KVAR KVA
READ NEXT
1. Input Terminals
CAT III - 600V
2
WARNING!DO NOT UNDER ANY CIRCUMSTANCES EXCEED THESE RATINGS: - Voltage is not to exceed 800 Volts. - Wattage, Resistance and Continuity functions are not to be performed on circuits capable of delivering greater than 600 Volts. [. . . ] · Insert the black test lead into the COM terminal and the red test lead into the + terminal. · Connect the test probes in parallel with the load or circuit. · The power clamp automatically selects the proper range. · The current value is shown on the main display and the voltage value is shown on the upper display. AC + DC Apparent Power/Reactive Power Measurement (kVA/kVAR)
61-802
Power Clamp
3ØPF AC+DC 2000KW 2000A
HOLD
PFKW HzV VA
OFF
Overload Protection: 800V TRMS Measurements Accuracies specified at Crest Factor <3. 5
KVARKVA 3Ø3W 3Ø4W
True RMS
DC A/W ZERO
REC
3Ø KVAR KVA
READ NEXT
CAT III - 600V
61-802
Power Clamp
3ØPF AC+DC 2000KW 2000A
HOLD
PFKW HzV VA
OFF
KVARKVA 3Ø3W 3Ø4W
True RMS
Note: Before taking a kVA/kVAR measurement, the DC A/W ZERO button must be used to zero the current reading. If the current reading is not zero, the kVA and kVAR values might be incorrect.
DC A/W ZERO
REC
3Ø KVAR KVA
READ NEXT
CAT III - 600V
9
10
To Measure AC+DC Apparent and Reactive Power (kVA/kVAR) in a single phase 2-wire system · Set the rotary switch to A/V. · Press the DC A/W ZERO button to zero the reading. · Set the rotary switch to kVA/kVAR. · Insert the black test lead into the COM terminal and the red test lead into the + terminal. · Connect the black test probe to the neutral conductor and the red test probe to the hot conductor. · Using the trigger to open the jaws, fully enclose the hot conductor within the clamp. · Release the trigger and be sure that the jaws have closed completely. · Apparent Power (kVA) is a calculated value based on the formula VA kVA = 1000 · Reactive Power (kVAR) is a calculated value based on the formula kVAR = (kVA)2 - (kW)2
33W AC+DC Power Measurements
Kilowatt Range Resolution Accuracy (AC+DC True Power) Range 0-99. 99kW 100-999. 9kW 1000-1200kW 0. 01kW 0. 1kW 1kW ±(2. 0% +5) Voltage/Current
±(2. 0% +0. 05) 600VAC, 800VDC 2000A AC/DC
Power Factor 0. 2-1. 0 for 12W, 13W, 33W, and 34W
KVAR Range Resolution Accuracy (AC+DC Reactive Power) 0-99. 99kW 100-999. 9kW 1000-1200kW 0. 01kW 0. 1kW 1kW ±(2. 0% +5) Voltage/Current Range 2000A AC/DC
±(2. 0% +0. 05) 600VAC, 800VDC
In a three phase 3-wire system, the 61-802 power clamp measures the true power (kW), power factor (PF), apparent power (kVA), and reactive power (kVAR) of the system. These values are calculated based on the formulas kW33W = PF33W = kVA33W = kWRS(L1L2) + kWTS (L3L2) kW 33W kVA 33W kW233W - kVAR233W
· To obtain a more accurate kVAR value when the power factor (PF) is greater than 0. 91, use the 33W function. · The kVA value is shown on the main display and the kVAR value is shown on the upper display. · Positive kVAR (+) indicates a capacitive load, while negative kVAR (-) indicates an inductive load. Note: The "+" sign on the jaw must face the power source for correct measurement. To measure AC+DC Apparent and Reactive Power (kVA/kVAR) in a single phase 3-wire system See section on 13W AC+DC Power Measurements
kVAR33W = kVARS(L1L2) + kVARTS(L1L2) To Measure AC+DC Power Measurements in a three phase 3-wire system · Set rotary switch to 33W without jaws clamping onto any wire. · The LCD display will show a flashing R to indicate that the meter is ready for the first measurement. · If the watt reading is not zero, press the DC A/W ZERO button once to zero out the watt reading. · Insert the black test lead into the COM terminal and the red test lead into the + terminal. · Pressing the READ NEXT button clears the stored data from memory and readies the power clamp for another three phase 3-wire calculation. [. . . ] RST is shown on the LCD display to indicate that this is a measurement of the total system. · Pressing the 3 KVAR KVA button toggles to display the apparent power (kVA) of the system, which is shown on the main display, and the reactive power (kVAR), which is shown on the upper display. · Pressing the READ NEXT button clears the stored data from memory and readies the power clamp for another three phase 3-wire calculation. Note: The "+" sign on the jaw must face the power source for correct measurement. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE IDEAL ND2396
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.