Detailed instructions for use are in the User's Guide.
[. . . ] If the instructions for installation for the gas hob specify a greater distance, this must be adhered to. Expansion wall plugs are provided to secure the hood to most types of walls/ceilings. However, a qualified technician must verify suitability of the materials in accordance with the type of wall/ceiling. The wall/ceiling must be strong enough to take the weight of the hood. [. . . ] The premises where the appliance is installed must be sufficiently ventilated, when the kitchen hood is used together with other gas combustion devices or other fuels. The suctioned air must not be conveyed into a conduit used for the disposal of the fumes generated by appliances that combust gases or other fuels. The flaming of foods beneath the hood itself is severely prohibited. The use of exposed flames is detrimental to the filters and may cause a fire risk, and must therefore be avoided in all circumstances. Any frying must be done with care in order to make sure that the oil does not overheat and burst into flames. With regards to the technical and safety measures to be adopted for fume discharging it is important to closely follow the regulations provided by the authorised authorities. The hood must be regularly cleaned on both the inside and outside (AT LEAST ONCE A MONTH). This must be completed in accordance with the maintenance instructions provided in this manual). Failure to follow the instructions provided in this user guide regarding the cleaning of the hood and filters will lead to the risk of fires. Do not use or leave the hood without the lamp correctly mounted due to the possible risk of electric shocks. We will not accept any responsibility for any faults, damage or fires caused to the appliance as a result of the non-observance of the instructions included in this manual. Therefore, we recommend oserving these instructions. The manufacturer declines all responsibility for any damage to the motor or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations. maintenance of the anti-grease filters Traps cooking grease particles. This must be cleaned once a month using non aggressive detergents, either by hand or in the dishwasher, which must be set to a low temperature and a short cycle. When washed in a dishwasher, the grease filter may discolour slightly, but this does not affect its filtering capacity. To remove the grease filter, pull the spring release handle. mAINTENANCE
Maintenance of the charcoal filter It absorbs unpleasant odours caused by cooking. The saturation of the activated charcoal occurs after more or less prolonged use, depending on the type of cooking and the regularity of cleaning of the grease filter. In any case it is necessary to replace the cartridge at least every four mounths. The carbon filter may NOT be washed or regenerated. Apply one on each side covering both grills protecting the motor propeller, then turn the filter central handles P clockwise. [. . . ] Instead it should be taken to the appropriate collection point for the recycling of electrical and electronic equipment. Disposal must be carried out in accordance with local environmental regulations for waste disposal. For more detailed information about treatment, recovery and recycling of this product, please contact your local authority. Model H 563 Height (Ducting version) 73, 3-114, 8 cm Height (Filter version) 81, 8-114, 8 cm Width 59, 9 cm Depth 51, 5 cm Gross weight: 12, 15 Kg Total absorption 200 W Motor absorption 1x120 W Lamp absorption 2x40 W (E14) Exhaust pipe Ø 15 cm Model H 573 Height (Ducting version) 73, 3-114, 8 cm Height (Filter version) 81, 8-114, 8 cm Width 69, 9 cm Depth 51, 5 cm Gross weight: 14 Kg Total absorption 200 W Motor absorption 1x120 W Lamp absorption 2x40 W (E14) Exhaust pipe Ø 15 cm Model H 593 Height (Ducting version) 73, 3-114, 8 cm Height (Filter version) 81, 8-114, 8 cm Width 89, 9 cm Depth 51, 5 cm Gross weight: 14, 85 Kg Total absorption 200 W Motor absorption 1x120 W Lamp absorption 2x40 W (E14) Exhaust pipe Ø 15 cm This appliance conforms to the following EEC Directive: • “Low Voltage Equipment” Directive 2006/95/EC (12-12-2006) • “Electromagnetic Compatibility” Directive 2004/108/EC (15-12-2004)
TECHNICAL DATA
EN
MALFUNCTIONS
If something appears not to be working properly, do the following simple checks before calling Technical Service: • If the hood is not working: Check that: - The power has not been disconnected. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE INDESIT H563IX
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.