[. . . ] SHOULD THE APPLIANCE NOT FUNCTION, DISCONNECT IT FROM THE SUPPLY AND CALL THE NEAREST TECHNICAL ASSISTANCE CENTRE. ALWAYS CHECK THAT THE CONTROL KNOBS ARE IN THE POSITION "ZERO" (OFF) WHEN YOU FINISH USING THE HOB.
22
Introduction
THE IDENTIFICATION PLATE, WITH TECHNICAL DATA, SERIAL NUMBER AND MARKING IS CLEARLY VISIBLE UNDER THE CASING. THE PLATE ON THE CASING MUST NOT BE REMOVED. BEFORE CONNECTING THE DEVICE, MAKE SURE THAT IT HAS BEEN REGULATED FOR THE TYPE OF GAS THAT WILL FEED IT, CHECKING THE LABEL UNDER THE HOB. [. . . ] Keep a minimum distance of 10 mm between the bottom of the unit and the panel surface. The panel has to be easily removable to allow access in the event of technical service.
25
Instructions for the installer
3 ELECTRICAL CONNECTION
Make sure that the voltage and capacity of the power line conform to the data shown on the plate located under the casing. Do not remove this plate for any reason. The plug on the end of the supply cable and the wall socket must be the same type and conform to the current electrical system regulations. Check that the power line is adequately grounded. On the power line, install an omnipolar cut-off device with contact cutoff distance greater than or equal to 3 mm, located in an easily accessible position near the unit. Do not use reducers, adapters or shunts.
If the power cable is replaced, the wire section on the new cable must not be less than 1. 0 mm 2 (3 x 1. 0 cable), keeping in mind that the end to be connected to the hob must have the ground wire (yellow-green) longer by at least 20 mm. Use only H05V2V2-F cable or similar which has a maximum temperature of 90°C. Any replacement needed should be carried out by a specialised technician who should make the mains connections according to the following diagram. L = brown N = blue = yellow-green
The manufacturer will not be liable for any damage to persons or property caused by non-observance of the above instructions or deriving from the tampering of even a single part of the hob.
26
Instructions for the installer
4 GAS CONNECTION
Connection to the gas mains may be made with a rigid copper pipe or with a flexible pipe and conforming to the provisions defined by standard regulations in force. To facilitate connection, fitting A on the rear of the appliance may be adjusted laterally. Move the Venturi tube D to regulate the air flow until distance "X" is reached indicated in the chart in paragraph "5. 4 Regulation of primary air" and then secure the tube by means of screw A. After the regulations have been carried out, restore the seals with sealing wax or equivalent material.
Burner
Rated heating capacity
LPG G30/G31 28/37 mbar Nozzle diameter By-pass 1/100 mm 1/100 mm 48 30 (1) 62 30 (1) 76 37 (2) 85 43 67 43 (3) 87 55 (4) 48 30 (1) 93 55 (4)
Reduced flowrate (W)
Flowrate g/h G30
Flowrate g/h G31
Auxiliary Semirapid Rapid Rapid large Fish pan Ultra rapid Double Internal crown External
1. 05 1. 65 2. 55 3. 1 2 3. 3 1. 15 3. 8
380 380 650 750 750 1200 380 1200
76 120 185 225 145 240 84 276
75 118 182 222 143 236 82 271
(1)= 33 for valveless appliances. (4)= 65 for valveless appliances.
30
Instructions for the installer
5. 3 Regulation for natural gas
The hob has been inspected for G25 (2L 3B/P) at a pressure of 25 mbar. To allow the unit to work with this type of gas, perform the same operations described in paragraph "5. 2 Regulation for LPG", but choose the nozzles and regulate the primary air for natural gas, as shown in the following table and in paragraph "5. 4 Regulation of primary air". After the regulations have been carried out, restore the seals with sealing wax or equivalent material. Rated G25 25 mbar Burner heating capacity Nozzle diameter Reduced flowrate 1/100 mm (W) Auxiliary 1. 05 76 380 Semirapid 1. 65 98 380 Rapid 2. 7 123 650 Rapid large 3. 1 130 750 Fish pan 2. 15 110 750 Ultra rapid 3. 3 135 1200 1. 05 76 380 Double Internal crown External 3. 9 150 1200
31
Instructions for the installer
5. 4
Burner Auxiliary (1) Semirapid (2) Rapid (3) Rapid large (4) Fish pan (7) Ultra rapid (5) Ultra rapid (8) Double crown (6) Double crown (9) Internal External Internal External
Regulation of primary air
G25 25 mbar 1. 0 1. 0 0. 5 1. 5 1. 5 1. 5 1. 5 1. 0 1. 5 1. 0 1. 0 G30/G31 28/37 mbar 1. 0 1. 5 1. 5 10. 0 2. 5 2. 5 2. 5 6. 0 10. 0 1. 5 4. 0
Referred to distance "X" in mm.
To identify the burners on your hob, refer to the drawings in point "6. 3 Arrangement of burners on hob "
32
Instructions for the installer
6 FINAL OPERATIONS
Having carried out the above adjustments, reassemble the appliance following, backwards, the instructions in paragraph "5. 1 Removing the hob".
6. 1
Regulation of minimum for natural gas
Replace the components on the burner and slide the knobs on the gas tap pins. Light the burner and set it at minimum position. Remove the knob and turn the regulation screw inside or next to the gas tap pin (depending on the model) until you get a suitable minimum flame. Replace the knob and check burner flame stability: (rapidly turning the knob from maximum to minimum position, the flame should not go out).
6. 2
Regulation of minimum for LPG
To regulate the minimum for LPG, completely tighten (clockwise) the screw inside or next to the gas tap pin (depending on the model). The diameters of the by-passes for each burner are given in table "5. 2 Regulation for LPG". After having regulated the device with a gas other than the one tested, replace the label located on the bottom enclosure with the one that corresponds to the new gas. [. . . ] In normal use of the hob, the stainless steel burner caps and panstands tend to be burnished by the high temperature. Clean these parts using very fine abrasive sponges or similar commercial products. Then use a specific paste polish to restore the steel's shine. Your local authorised after-sales technician is able to supply professional products for appliance cleaning and care. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE INDESIT VRA 631 T B
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.