Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual INFOSEC IPEL EVOLUTION 700 VA. We hope that this INFOSEC IPEL EVOLUTION 700 VA user guide will be useful to you.
Lastmanuals help download the user guide INFOSEC IPEL EVOLUTION 700 VA.
Manual abstract: user guide INFOSEC IPEL EVOLUTION 700 VA
Detailed instructions for use are in the User's Guide.
[. . . ] Laser printers should not be connected to the UPS as they consume too much power. Make sure that the power supply required does not exceed the UPS's capacity. We recommend using an optimum power load equivalent to half or one third of the nominal power for longer backup functioning and longer battery life. [. . . ] You will find the technical information you require on your guarantee or on the identification plate on the back of the unit. If convenient you may write down the details in the following box. At the end of their lives, they have to be collected separately. Control When you receive your equipment, open the packaging and check that your UPS has not been damaged. The packaging includes : a UPS unit, a user's guide, a power cable, 3 IEC output cables, 1 RJ11 cable. Charging This unit is shipped from the factory with its internal battery fully charged, however, some charge may be lost during shipping and the battery should be recharged prior to use. Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged-in for at least 8 hours with no load. Place and installation The UPS has been designed to operate in a protected environment, at temperatures between 0° C and 40° C and at a rate of humidity ranging between 0 % and 90% (no condensation). do not obstruct the ventilation grills. Install the unit in an environment which is free from dust, chemical vapours and conductors. Moreover, in order to avoid any interference, keep the UPS at least 20 cm away from the CPU (central processing unit). Then connect one computer-related device into each of the power receptacles supplied on the back of the UPS. You can also connect a device which does not require backup time, like a printer for example, into the surge protected and filtered outlet. Turn On/Off To turn on the UPS unit, press the power switch lightly. To turn off the UPS unit, press the power switch again. DC Start All of the iPEL evolution units are equipped with an integrated DC start function. To start the UPS in absence of power supply and with a full battery, press the button. Green Power Function All iPEL is equipped with Green Power Function. [. . . ] We therefore recommend that users recharge the battery once every 3 months when the unit is not in use in order to compensate for natural discharging. UPS back-up functioning time will depend on the load powered, the age and the condition of the batteries. Batteries have a very high short circuit current : connection errors could cause electric arcs resulting in serious burns. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE INFOSEC IPEL EVOLUTION 700 VA
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual INFOSEC IPEL EVOLUTION 700 VA will begin.