If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual INTELLISENSE FG-1008. We hope that this INTELLISENSE FG-1008 user guide will be useful to you.

Lastmanuals help download the user guide INTELLISENSE FG-1008.


Mode d'emploi INTELLISENSE FG-1008
Download
Manual abstract: user guide INTELLISENSE FG-1008

Detailed instructions for use are in the User's Guide.

[. . . ] Test the location thoroughly whenever there are window coverings present. · Do not mount the detector within 3 feet (0. 9 m) of forced air ducts, sirens, or bells measuring two inches (5 cm) or more in diameter. · If the magnetic contact is enabled, the glassbreak housing must be mounted less than 1" (2. 5 cm) from the magnet housing. The glassbreak detector and magnet housings must be aligned and mounted parallel to each other. [. . . ] Cut and strip wire ends 1/4" (6. 5 mm). Wire the detector as shown (use 22 - 18 AWG). Reverse polarity connections will not damage the detector. Replace front cover. Figure 4a Routing the wires through the mounting plate Back view of mounting plate 3 Figure 4b Align MAGNET and "SWITCH" Mount the PCB housing and magnet housing no more than 1" (2. 5 cm) apart. Front view of mounting plate "SWITCH" location indicator MAGNET Breakout tab Wire entry hole Route wire through wiring channel and wire entry hole of mounting plate Secure magnet housing on door or window parallel to the detector housing Secure mounting plate on door or window frame with #6 (M 3. 5) mounting screws Figure 5 Route wires through the PCB housing and connect to terminal block. Connect PCB housing to mounting plate. After mounting plate is secured to wall, route wire through wire entry hole of PCB housing and PCB board. Strip wire ends and connect to terminal block. Breakout tab FG-1008 CONFIGURATION Configure jumpers W1-W3 to best suit the application. W1: The FG-1008 comes with the LEDs enabled. To disable the LED operation, remove the jumper from position W1 on the PCB. W2: The detector comes with alarm LED LATCH disabled. To enable alarm LED LATCH, place a jumper across W2. W3: The FG-1008 comes with the magnetic contact enabled. To disable the magnetic contact, place a jumper across W3. PCB wire entry hole Terminal block NOTE: For proper wiring methods, refer to the National Electrical Code, NFPA 70. Breakout tab STEP Figure 6 Jumper settings JUMPER W1 (LED) W2 (LATCH) W3 (CONTACT DISABLE) 1 2 4 = Factory defaults ON LEDs are enabled OFF LEDs are disabled except during powerup test Red alarm LED lights for 5 seconds when detector alarms Magnetic contact is enabled TESTING The FG-1008 should be tested at least once each year. Test the detector with the FG-701 Glassbreak Simulator. The model FG-700 Glassbreak Simulator can be used if it is set for the TEMPered glass sound. Other glassbreak simulators will not give an accurate indication of range. You must place the FG-1008 into Test Mode before you can test the detector. 2 Red alarm LED latches ON when detector alarms1, 2 Magnetic contact is disabled Latched alarm LED does not affect timing of alarm relay. Reset the alarm LED by removing and restoring power, or by momentarily removing and replacing the LATCH jumper. TESTING continued. . . To activate Test Mode: 1. Position the simulator within 5 feet (1. 5 m) of the detector. Switch the FG-701 to ACTIVATE and MANual modes. Point the front of the simulator at the detector and press the red start button. You should hear a short buzz from the simulator, and the green LED on the FG1008 should begin flashing about once per second to indicate it is in Test Mode. [. . . ] To reset the alarm relay, the magnetic contact must be closed (the door or window on which it is mounted must be closed). FG-701 Glassbreak Simulator 3 LED Indicators The two LEDs shining through the front cover are used to indicate the detector's operational status. The following table summarizes the LED operation when the LEDs are enabled. Condition Normal, no event Normal, event detected Normal, break detected Power-up self-test Trouble detected Test mode, no alarm Test mode, event detected Test mode, alarm SPECIFICATIONS Range: 8' (2. 4 m) maximum No minimum range Alarm relay: Form A, 250 mA maximum 25 VDC maximum Alarm duration: 5 seconds (unaffected by alarm LED latching) Tamper switch: Cover tamper 25 mA maximum 24 VDC maximum Power requirements: 8 - 14 VDC; 17 mA typical at 12 VDC, 30 mA max. ; AC Ripple: 4 Volts peak to peak at nominal 12 VDC Operating temperature: 32° to 120°F (0° to 49°C) Storage: -4° to 122° F (-20° to 50° C) RFI immunity: 30 V/m, 10 MHz - 1000 MHz ESD immunity: 10 kV, Discharges of either polarity to exposed surfaces Magnetic contact: Make gap 0. 9" minimum Break gap 2. 2" maximum Dimensions: Glassbreak housing: 4-9/16" x 15/16" x 1-1/4" (11. 6 cm x 2. 3 cm x 3. 2 cm) Magnet housing: 4-9/16" x 15/16" x 1/2" (11. 6 cm x 2. 3 cm x 1. 3 cm) Weight: 2. 9 oz. , (81 g) packaged product: 3. 8 oz. , (108 g) Accessories: FG-701 Glassbreak Simulator Approvals/listings: FCC verified UL listed Green LED OFF Flicker OFF ON, one second Flash ON/OFF Flash once per second Flicker Flash once per second Red LED OFF OFF ON ON, one second Flash OFF/ON OFF OFF ON Self-Tests The FG-1008 automatically performs a series of self-tests during power-up, and continuously. If any self-test fails, the detector will signal trouble by flashing the LEDs alternately once per second. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE INTELLISENSE FG-1008

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual INTELLISENSE FG-1008 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag