User manual INTELLISENSE FG-1025

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual INTELLISENSE FG-1025. We hope that this INTELLISENSE FG-1025 user guide will be useful to you.

Lastmanuals help download the user guide INTELLISENSE FG-1025.


Mode d'emploi INTELLISENSE FG-1025
Download
Manual abstract: user guide INTELLISENSE FG-1025

Detailed instructions for use are in the User's Guide.

[. . . ] loop, no EOL resistor · Mount the unit within 25' (7. 6 m) of the glass. There is no minimum range, but the unit must have a clear line-of-sight and a clear view of the protected glass. The preferred location is on the wall or ceiling directly opposite the glass. When wall mounting, mount the unit at a height of at least 6 feet (1. 8 m) to avoid accidental screening if furniture in the room is moved. [. . . ] Other glass-break simulators will not give accurate indication of range. You must place the FG-1025 in Test Mode before you can test the unit. Switch the FG-701 to ACTIVATE and MANual modes. Point the front of the simulator at the unit and press the red start button. (Refer to Figure 6. ) You should hear a short buzz from the simulator, and the green LED on the FG-1025 should begin flashing about once per second to indicate it is in Test Mode. NOTE: In Test Mode the LED disable switch is overridden. Use needle-nose pliers to break out the plastic tab on the back of the unit. (See Figure 4. ) The wall tamper arm will then extend through the hole. The wall tamper screw (not provided) should be a flat-head #8 (M 4) or #10 (M 5) screw. Install the wall tamper screw so that it will just make contact with the bottom of the tamper cavity when the unit is mounted. After installing the wall tamper screw, position the unit over it and mark the locations for the mounting screws. TESTING (Continued) IMPORTANT: Some environmental factors may reduce the sensor activation range. If you do not see the green LED flashing after pressing the red start button, move closer to the unit and try again. After testing, exit the Test Mode using the same procedure for activating the Test Mode. The FG-1025 also will automatically exit Test Mode after ten minutes. LED Indicators: The two LED's on the front cover are used to indicate the sensor's operational status. The following table summarizes the LED operation when the LED's are enabled. Condition Normal, no event Normal, event detected Normal, break detected Power-up self-test Trouble detected Test mode, no alarm Test mode, event detected Test mode, alarm Green LED OFF Flicker OFF ON, one second Flash ON/OFF Flash once per second Flicker Flash once per second Red LED OFF OFF ON ON, one second Flash OFF/ON OFF OFF ON Red Start Button Figure 6 If an FG-701 is not available, or if for any reason remote activation cannot be used, use a screwdriver to short the test pads at location S3 on the PCB (see Figure 1). Make sure to close the front cover of the FG-1025 before beginning test. Place the unit in Test Mode as described above. Set the FG-701 switches to the TEST and FLEX positions. The simulator will "click" on and start an eight second armed period. Position the FG-701 near the farthest point of the protected glass and point it directly at the FG-1025. Generate a flex signal by carefully striking the glass with a cushioned tool. The FG-701 will respond by producing a burst of glass-break audio. [. . . ] This warranty is void if the product held liable, whether directly or indirectly, for any loss or damage arising under this Limited is altered or improperly repaired or serviced by anyone other than IntelliSense factory service. For Warranty or otherwise, regardless of cause or origin, Seller's maximum liability shall not in any warranty service, contact the nearest IntelliSense service center. case exceed the purchase price of the product, which shall be fixed as liquidated damages and not as a penalty, and shall be the complete and exclusive remedy against Seller. THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE This warranty replaces all previous warranties and is the only warranty made by IntelliSense on DESCRIPTION ON THE FACE HEREOF. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE INTELLISENSE FG-1025

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual INTELLISENSE FG-1025 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag