If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual INTERMATIC 158TS10930. We hope that this INTERMATIC 158TS10930 user guide will be useful to you.
Lastmanuals help download the user guide INTERMATIC 158TS10930.
Detailed instructions for use are in the User's Guide.
[. . . ] Project1
7/27/04
4:30 PM
Page 1
24 HR DIAL TIME SWITCH WITH "SKIPPER®" AND SPRING-WOUND CARRY-OVER MOTOR
DOUBLE POLE SINGLE THROW (DPST)
IN TYPE 3R RAINPROOF ENCLOSURE,
MODEL: T174CR
LR3730
40 AMP. 40 AMP INDUCTIVE, OR TUNGSTEN OR 1000 VA. [. . . ] To make power connections remove 1/2 inch of insulation from wire ends. Insert bare ends of wire under the pressure plate of terminals. Use 3/16 or larger screwdriver to tighten terminal screws firmly. REPLACE INSULATOR BEFORE TURNING ON ELECTRICITY.
MINIMUM COPPER WIRE SIZE (AWG) MAX. INSULATION TEMP(°C) 75°C INSULATION MAX. 240 V.
PRESSURE PLATE TERMINAL SCREW MAKE SURE WIRE INSULATION CLEARS PRESSURE PLATE
14 12 10 8
15 20 30 40
60 60 60 75
1/2 1 2 -
2 2 1/2 3 5
N/A
N/A
PROGRAMMING INSTRUCTIONS 1. TO SET "ON" AND "OFF" TIMES: Hold trippers against edge of CLOCK-DIAL, pointing to time (AM or PM) when ON and OFF operations are desired, tighten tripper screws firmly. For additional tripper pairs on CLOCK-DIAL order 156T1978A. TO SET TIME-OF-DAY: Pull CLOCK-DIAL outward. Turn in either direction and align the exact time-of-day on the CLOCK-DIAL (the time now, when switch is being put into operation) to the pointer. [. . . ] This will not effect next operation.
CAUTION: TO AVOID SLOW SWITCH ACTION FAILURE, DO NOT OPERATE SWITCH MANUALLY NOR PLACE A TRIPPER 4 HOURS PRIOR TO ON/CUTOUT TRIPPER SWITCHING.
·
IN CASE OF POWER FAILURE, reset CLOCK-DIAL to proper time-of-day. See programming instructions.
158TS10930
INTERMATIC INCORPORATED
SPRING GROVE, ILLINOIS 60081-9698 [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE INTERMATIC 158TS10930
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.