If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual INTERMATIC IG1300 INSTALLATION. We hope that this INTERMATIC IG1300 INSTALLATION user guide will be useful to you.
Lastmanuals help download the user guide INTERMATIC IG1300 INSTALLATION.
Manual abstract: user guide INTERMATIC IG1300 INSTALLATION
Detailed instructions for use are in the User's Guide.
[. . . ] NOTE: ELECTRICAL GROUND IS REQUIRED FOR THIS UNIT TO FUNCTION PROPERLY AND SAFELY!
STEP 1 Verify that all parts are included for your system.
DESCRIPTION QUANTITY QUANTITY
(IG1300-2T-1C)
(IG1300-4T-2C)
PanelGuard IG1300 AC Voltage Protection Device with 30" wire leads Mounting Plate Wire channel cover 4-wire (2-pair) Telephone protection module 1-circuit coaxial cable protection module
1 1 1 1 1
1 1 1 2 2
STEP 2 Tools and additional materials required. AC Voltmeter or Voltage tester Screwdrivers Flat or phillips blade for cabinet mounting screws. Torx T-20 for internal screws Lineman's pliers or wire strippers Hammer (optional) 3 each 1-1/4" x #10 sheet metal, wood or masonry screws
AC Voltage Protection Device
Mounting Screw Keyhole Torx T-20 in Hole A
Mounting Plate Hole D Torx T-20 in Hole C Torx T-20 in Hole B (hole E
located under wire channel cover
Coaxial Cable protection module Mounting Screw Hole (second hole
located under wire channel cover)
Wire Channel Cover
Hole F
4-wire Telephone protection modules
Figure 1
STEP 3 Select a location for the Surge Protection Device (SPD) which will allow convenient connection to the panel while keeping the lead wires as short as possible. Use an AC voltmeter or circuit tester across two breaker outputs to confirm that there is 240 volts between them. [. . . ] Make sure that enough wire is available to reach each terminal block on the telephone protection modules. Cut each wire pair and strip the end to a length of 5/16". Route the wires through the knockout and insert the stripped end of each wire into the terminal blocks as shown in Figure 3. Be sure to route the wires from the outside phone connection to the "IN" terminal and the wires to the house phones to the "OUT" terminal. Secure each wire by tightening the terminal block screws. NOTE: Exercise caution to ensure that each wire of a telephone pair is in line to prevent polarity reversal. STEP 14 Route the coaxial cable through the knockout. If insufficient space is available in the knockout, the second knockout may be used. Connect the cable to the protection module making sure that the connectors are tightened snugly. STEP 15 Connect the AC Power protection to the electrical panel. Measure each wire lead and cut it to proper length. Each wire should be as short as possible to provide optimum operation. NOTE: The protector functions best if all bends in the wire leads are rounded, ideally to a 4" radius. Connect the Green Ground wire to the panel ground bus first. Connect the White Neutral wire to the Neutral bus if the electrical panel has one. Many panels have a common Neutral and Ground bus which will result in both the Green and White wires connecting to the same bus. STEP 16 Connect the two black wires to two separate 15 or 20 amp single-pole circuit breakers. STEP 17 Check to be sure that all wires are securely fastened and all screws are tight. Confirm that the protector is wired to the correct breakers by measuring the voltage between the two black leads. A voltage of 220 to 240 VAC means that the IG1300 is connected across both sides of the electrical service. STEP 18 Replace the cover or trim panel on the electrical cabinet. Return all breakers to their original positions and check the IG1300 for two green indicators.
4
STEP 19 Close the cover on the IG1300. [. . . ] No employee of Intermatic or any other party is authorized to make any warranty in addition to those made in this agreement.
7
(7) Claim Procedure In order to submit a claim for warranty service the purchaser must: (A) Contact the Intermatic Insurance Claims Center at 1-800-270-7227 before having the damaged equipment repaired. (B) Request that an Incident Claim Report be written regarding the damage including descriptions and model identification (if available) of the equipment that was damaged. Record the Warranty Claim Number for future reference. (C) File a claim for the damaged equipment with your homeowner's (or renter"s) insurance company. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE INTERMATIC IG1300 INSTALLATION
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.