User manual INTERMATIC LH

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual INTERMATIC LH. We hope that this INTERMATIC LH user guide will be useful to you.

Lastmanuals help download the user guide INTERMATIC LH.


Mode d'emploi INTERMATIC LH
Download
Manual abstract: user guide INTERMATIC LH

Detailed instructions for use are in the User's Guide.

[. . . ] Refer to the wiring configurations and voltages on page 2 and 3 for additional information. The Commercial Series of SPD must be installed downstream from a 400 amp or less current interruption device or circuit breaker. Remove the knock out from the load center or equipment panel that will position the SPD for the shortest wire lead distance. [. . . ] Cut each wire lead to the proper length. Connect the GREEN wire lead to the system ground. Connect the WHITE wire lead to the system neutral bus. When a panel is the main panel, the neutral bus may be the same as the ground bus. Connect each phase wire to a circuit breaker. Make sure that the phase wires have the correct voltage level between them. Note that for the 240 volt High Leg Delta, the wire for the High Leg is colored RED, and must be connected to the leg that measures approximately 208 volts to neutral and to ground. Failure to comply with this instruction will result in failure of the SPD and void the warranty. Check all connections for proper tightness or torque. Suggested torque values are published by the circuit breaker manufacturer. Make sure that each indicator on the SPD is ON. If not, turn power off and recheck each installation step listed above. For troubleshooting assistance, call Intermatic at 815-675-7000 and ask for Technical Support. 2. 14. INSTALLATION NOTE: The cover of the SPD may be rotated 180 degrees if the device must be installed in an inverted position. Carefully remove the four corner bolts, rotate the cover and reinstall the bolts. Care must be exercised to prevent damage to the wire leads to the LED indicators. WIRING CONFIGURATIONS NOTE: All `LH' units must be installed downstream from breaker or fuse of 400 amps or less capacity. A 30-amp breaker is recommended as a convenient connection point when installing on a breaker panel. 120 volt Single Phase Transformer Secondary Load Center Use 30 amp Breakers CONFIGURATION VOLTAGE L1 Black/Negro Noir Line to Neutral Line to Ground Model IG1201LH 120 120 N G White/Blanco Blanc Green/Verde Vert 120/240 volt Single (Split) Phase Load Center L1 L2 N G Transformer Secondary Use 30 amp Breakers Black/Negro Noir Black/Negro Noir White/Blanco Blanc Green/Verde Vert CONFIGURATION VOLTAGE Line to Line Line to Neutral Line to Ground Model IG2401LH 240 120 120 120/208 volt Three Phase WYE Transformer Secondary Load Center L1 L2 L3 N G Use 30 amp Breakers CONFIGURATION VOLTAGE Black/Negro Noir Black/Negro Noir Black/Negro Noir White/Blanco Blanc Green/Verde Vert Line to Line Line to Neutral Line to Ground Model IG2083LYH 208 120 120 120/240 volt Three Phase Delta High Leg Delta Transformer Secondary Load Center L1 L2 L3 N G Use 30 amp Breakers CONFIGURATION VOLTAGE Black/Negro Noir Red/Rojo Rouge Black/Negro Noir White/Blanco Blanc Green/Verde Vert Model IG2403LDH Line to Line Line to Neutral High Leg to Neutral Line to Ground High Leg to Ground 240 120 208 120 208 277/480 volt Three Phase WYE Transformer Secondary Load Center L1 L2 L3 N G Use 30 amp Breakers CONFIGURATION VOLTAGE Black/Negro Noir Black/Negro Noir Black/Negro Noir White/Blanco Blanc Green/Verde Vert Line to Line Line to Neutral Line to Ground Model IG4803LYH 480 277 277 480 volt Three Phase DELTA Transformer Secondary Load Center L1 L2 L3 G CONFIGURATION VOLTAGE Use 30 amp Breakers Black/Negro Noir Black/Negro Noir Black/Negro Noir Green/Verde Vert Model IG4803LDH Line to Line Line to Ground 480 480 Contact your Intermatic Representative or Distributor for information on other hardwired panel Surge Protection Devices. Discover the convenience of integral fusing and the versatility of replaceable protection modules in Intermatic's full line of Surge Protection Devices. TEN YEAR LIMITED PRODUCT WARRANTY For ® INTERMATIC HARDWIRED SURGE PROTECTION DEVICES (1) What Is Covered By This Limited Warranty Repair or Replacement of Product Intermatic Incorporated ("Intermatic") warrants to the original purchaser only, Intermatic models IG1201LH, IG2401LH, IG2083LYH, IG2403LDH, IG4803LYH, IG4803LDH or IG1201EH, IG2401EH, IG2083YEH, IG2403DEH, IG4803YEH, IG4803DEH Surge Protection Devices (each a "Product") shall be free from defects in material or workmanship for a period of ten years (120 months) from date of purchase or 126 months from date of manufacture. [. . . ] TO THE EXTENT ALLOWED BY LAW, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE DURATION OF THIS LIMITED WARRANTY. (4) Limitation of Remedies IN NO CASE SHALL INTERMATIC BE LIABLE FOR ANY SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES BASED UPON BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE, STRICT TORT, OR ANY OTHER LEGAL THEORY. SUCH EXCLUDED DAMAGES INCLUDE, BUT ARE NOT LIMITED TO, DAMAGE TO SOFTWARE, LOSS OF DATA, LOSS OF PROFITS, LOSS OF SAVINGS OR REVENUE, LOSS OF USE OF THE PRODUCT OR ANY ASSOCIATED EQUIPMENT, COST OF CAPITAL, COST OF ANY SUBSTITUTE EQUIPMENT, FACILITIES OR SERVICES, DOWNTIME, THE CLAIMS OF THIRD PARTIES INCLUDING CUSTOMERS, DAMAGE TO PROPERTY AND PERSONAL INJURY. SOME STATES DO NOT ALLOW LIMITS ON WARRANTIES OR ON REMEDIES FOR BREACH IN CERTAIN TRANSACTIONS. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE INTERMATIC LH

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual INTERMATIC LH will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag